Cause: The machine was not able to extend the in-carrier because there is a board on the in-lifter,but it was not sure whether there is a board clamped in the in-carrier. If the in-carrier has clamped a board with parts …
LX044: IN-carrier left front opened sensor
LX045: IN-carrier left rear opened sensor
LX046: IN-carrier right front opened sensor
LX047: IN-carrier right rear opened sensor
------------------------------
Code: 15010C03
Display: Board check error:I_CRRY
No brd on in-carrier Chk status of brd
Used by: CP643
Cause: An in-carrier board sensor has turned OFF (indicating that the first or second board is absent)
before the main lifter began loading boards from the in-carrier,after having indicated the presence of the
board in question when the in-carrier arrived at the extended limit.
Remedy: Adjust the in-carrier board sensors (the I/O input signals listed below) ensuring they correctly
detect the presence of boards clamped by the in-carrier.
I/O input signals:
LX018: In-carrier 1 board sensor
LX019: In-carrier 2 board sensor
------------------------------
Code: 15010C04
Display: Interlock alarm:I_CRRY
Chk conveyance brds between in-carrier and main conv.
Board check error:I_CRRY
In-carr brd conf sensor on Adj sensor so it turns off
Used by: CP643
Cause: The in-carrier board sensors are abnormal. ( For example,a sensor is ON even though it should be
OFF.
Remedy: Make sure the in-carrier board sensors (the I/O input signals listed below) tuen ON and OFF
correctly.
I/O input signals:
LX018: IN-carrier 1 board sensor
LX019: IN-carrier 2 board sensor
------------------------------
Code: 15010C05
Display: Cylinder cycle alarm:I_CRRY
I_CRRY board transfer time up
Used by: CP643
Cause: The in-carrier was extended,but the extended limit sensor did not turn
ON within the specified time.
The in-carrier was retracted,but the retracted limit sensor did not turn ON within the specified time.
The in-carrier extended and retracted limit sensors are both ON.
Remedy: Make sure the in-carrier extends and retracts smoothly.
Make sure the extended and retracted limit sensors have been attached at the correct positions.
Make sure the extended and retracted limit sensors (the I/O input signals listed below) turn ON and OFF.
Make sure the extended and retracted limit sensors (the I/O input signals listed below) turn ON and OFF
correctly when the in-carrier is extended and retracted.I/O input signals:
LX01C: IN-carrier extended limit sensor
LX01D: IN-carrier retracted limit sensor
------------------------------
Code: 15010C06
Display: Interlock alarm:I_CRRY
Used by: CP643
第 1098 页
Cause: The machine was not able to extend the in-carrier because there is a board on the in-lifter,but it
was not sure whether there is a board clamped in the in-carrier. If the in-carrier has clamped a board with
parts mounted on the reverse side, there may be interference between the board and the one in the in-
lifter.
The machine was not able to retract the in-carrier because there is a board on the in-lifter,and there is
also a board clamped in the extended in-carrier.if the board clamped in the in-carrir has parts mounted
on the reverse side,there may
be interference between this board and the one on the in-lifter.
The machine was not able to retract the in-carrier from a position between the extended limit and the
retracted limit because there is a board on the in-lifter,but it is not sure whether there is a board clamped
in the in-carrier.if the in-carrier has clamped a board with parts mounted on the reverse side,there may be
interference between this board and the one on the in-lifter.
Remedy: Remove any boards from in the in-lifter.
Make sure the in-lifter board arrival sensors (the I/O input signals listed below) detect the presence of
boards in the in-lifter.
I/O input signals:
LX003: IN1 board deceleration start point sensor
LX004: IN1 board arrival sensor
LX007: IN1/IN2 board gap sensor
LX008: IN2 board deceleration start point sensor
LX009: IN2 board arrival sensor
LX017: In-conveyor board load sensor
------------------------------
Code: 15010C07
Display: Interlock alarm:I_CRRY
In-carrier not at extended position.
Used by: CP643,CP643M
Cause: Main conveyor movement for the conveyance of board(s) was terminated because the in-carrier is
out of position.
Remedy: If the in-carrier is at its extended position, check the extended and clamping limit sensors.If the
extended and clamping limit sensors are on, the carrier may be moving too fast and has recoiled out of
position.If the carrier is not at its extended position the movement of the carrier itself may require
adjustment.
------------------------------
Code: 15010D01
Display: PCB Transport Error:O_CRRY
Brd status at out-carr not clear Chk brd status
Used by: CP643
Cause: The out-carrier loaded a board (or boards) from the XY-table and unloadeded them to the out-
lifter,but the board status (that is, first or second board presence) detected by the out-conveyor board
sensors was deffernt from the board status that was detected when the boards were loaded from XY-table.
The in-carrier board sensors detected only the second board when the board check was performed. ( For
example,the out-lifter board sensors detected only the second board,even though the out-carrier loaded
both the first board and the second board from the XY-table.)
The out-carrier board sensors detected only the second board when the board check was performed.
Remedy: Make sure the out-carrrier board sensors (the I/O input signals listed below) correctly detect the
presence of boards clamped by the out-carrier.
I/O input signals:
LX038 OUT-carrier 1 board sensor
LX039 OUT-carrier 2 board sensor
Make sure the out-conveyor board sensors (the I/O input signals listed below) correctly detect the
第 1099 页
presence of boards on the conveyor.
I/O input signals:
LX00E: OUT1 board arrival sensor
LX00F: OUT2 board arrival sensor
------------------------------
Code: 15010D02
Display: Board-clamper error:O_CRRY
Check board clamp/unclamp limits on the O_CRRY
Used by: CP643
Cause: The out-carrier was closed,but the closed sensor did not turn ON within the specified time.
The out-carrier was opened,but the opened sensor did not turn ON within specified time.
The out-carrier opened and closed sensors are both ON.
Remedy: Make sure the out-carrier opens and closes smoothly.
Make sure the opened and closed sensors have been attached at the correct positions.
Make sure the opened and closed sensors (the I/O input signals listed below) turn ON and OFF.
Make sure the opened and closed sensors (the I/O input signals listed below) turn ON and OFF correctly
when the out-carrier is opened and closed.
I/O input signals:
LX048: OUT-carrier left front closed sensor
LX049: OUT-carrier left rear closed sensor
LX04A: OUT-carrier right front closed sensor
LX04B: OUT-carrier right rear closed sensor
LX04C: OUT-carrier left front opened sensor
LX04D: OUT-carrier left rear opened sensor
LX04E: OUT-carrier right front opened sensor
LX04F: OUT-carrier right rear opened sensor
------------------------------
Code: 15010D03
Display: Board check error:O_CRRY
No brd on out-carrier Chk status of brd
Used by: CP643
Cause: An out-carrier board sensor did not confirm a board (that is,the sensor did not turn ON) loaded
onto the out-carrier from the main lifter.
An out-carrier board sensor has turned OFF (indicating that the first or second
board is absent) before the out carrier began retracting,after having indicated
the presence of the board in question when that board was loaded onto the out-carrier from main lifter.
An out-carrier board sensor has turned OFF (indicating that the first or second
board is absent) before the out-carrier began retracting,after having indicated
the presence of the board in question during a board check performed when the out-carrier was at the
extended limit.
Remedy: Adjust the out-carrier board sensors (the I/O input signals listed below) ensuring they correctly
detect the presence of boards clamped by the out-carrier.
I/O input signals:
LX038: Out-carrier 1 board sensor
LX039: Out-carrier 2 board sensor
------------------------------
Code: 15010D04
Display: Board check error:O_CRRY
Out-carr brd conf sensor on Adj sensor so it turns off
Used by: CP643
Cause: The out-carrier board sensors are abnormal. ( For example,a sensor is ON even though it should