FUJI错误代码查询.pdf - 第741页
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2) "Over Instructed Z-Pulse" (QP2) Used by: QP242,QP201,QP202,QP203 Cause: The IN position was detected outside instructed Z-axis pulse range. (value r…
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?8F
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Unexecutable(Error Stop)" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command could not be executed because emergency stop input was received.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Clear the cause of the emergency stop, then re-execute the command.
------------------------------
Code: 12070?90
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Attrib D Trans before Reqst" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Attribute data has been transmitted without an attribute transmission request.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?91
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"PMC Memory Pool NG" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: PMC system check error #1 (memory pool error)
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?92
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"PMC Parameter Check Sum NG" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: PMC system check error no. 2 (parameter checksum error)
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?93
第 740 页
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Over Instructed Z-Pulse" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The IN position was detected outside instructed Z-axis pulse range.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
------------------------------
Code: 12070?94
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Zero Set Conditions Incomp" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The machine was unable to execute zero setting because the conditions for zero setting were not
met.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
------------------------------
Code: 12070?95
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Tray remover alarm" (QP2)
Remover docking error!(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: The operation of the tray remover is not correct. ? is the module number. "****" is the error
code.(QP2)
The removers at both stages are not attached to the lifter.(NP2,QP3)
Remedy: Check that the sensors around the tray remover are operating correctly.(QP2)
Return both removers to the lifters.(NP2,QP3)
------------------------------
Code: 12070?96
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Sent Atr Data w/o SENDAT" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Attribute data was transmitted even though no SENDAT command was received.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?97
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Sent Atr Data with Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Attribute data was transmitted after an error was reported in response to a SENDAT command.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
第 741 页
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?98
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Axis Incorrectly Specified" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The axis to perform an action has been incorrectly specified.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?99
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Program Trans before Reqst" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Program data has been transmitted without a program transmission request.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?9A
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"1 Packt Over Prog Trans Lim" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The length of a single program data transmission packet is too long.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?9B
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"1 Packt Ovr Atrib Trans Lim" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The length of a single program data transmission packet is too long.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
第 742 页