Display: Output program file name is too long. Used by: Cause: The output program filename is too long. Remedy: Check the filename. ------------------------------ Code: 21007534 Display: Permanent Set Table name is too l…
Code: 2100752B
Display: Part data read error
Used by:
Cause: Unable to read Part data.
Remedy: Check the file.
------------------------------
Code: 2100752C
Display: File read error
Used by:
Cause: Unable to read input file.
Remedy: Check the file.
------------------------------
Code: 2100752D
Display: File offset get error
Used by:
Cause: Unable to read the input file.
Remedy: Check the file and save the changes.
------------------------------
Code: 2100752E
Display: Can not feedback Fix device
Used by:
Cause: The specified device number for the fixed device is wrong.
Remedy: Check the PST file device numbers.
------------------------------
Code: 2100752F
Display: Skip device station over
Used by:
Cause: Unable to mount skip device.
Remedy: There are too many devices, so the skip device cannot be mounted. Reduce the number of
devices.
------------------------------
Code: 21007530
Display: Next device station over
Used by:
Cause: Unable to mount next device.
Remedy: There are too many devices, so the next device cannot be mounted. Reduce the number of
devices.
------------------------------
Code: 21007531
Display: New prodction file has no sequence data
Used by:
Cause: The new production program has no sequence data.
Remedy: Check the program's sequence data.
------------------------------
Code: 21007532
Display: Input program file name is too long
Used by:
Cause: Input program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007533
第 1943 页
Display: Output program file name is too long.
Used by:
Cause: The output program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007534
Display: Permanent Set Table name is too long
Used by:
Cause: The Permanent Set Table name is too long.
Remedy: Check the filename.
------------------------------
Code: 21007535
Display: Illegal format at Machine type table
Used by:
Cause: The machine type table format is illegal.
Remedy: Re-install the software.
------------------------------
Code: 21007536
Display: "No entry Machine name"
Used by:
Cause: A machine name has not been entered in the "Sep_data" section of the Part data.
Remedy: Enter a machine name and a feeder name in the "Sep_data" section of the Part data.
------------------------------
Code: 21007537
Display: "Couldn*t separate on St.2"
Used by:
Cause: An error occurred as the result of an attempt to allocate a component having a size smaller than
7 mm to Station 2.
Remedy: Components smaller than 7 mm cannot be allocated to Station 2. Specify this component for
fixed allocation to Station 1.
------------------------------
Code: 21007538
Display: "Not PST file"
Used by:
Cause: A file that has been specified as a PST file does not have the ".pst" extension.
Remedy: Specify a PST file as the permanent set table.
------------------------------
Code: 21007539
Display: "Feeder position in PT file is out of range"
Used by:
Cause: A feeder position specified as fixed in the PST file is outside the feeder station range.
Remedy: Specify a feeder position within the feeder station's range.
------------------------------
Code: 2100753A
Display: "Can not use cartridge type"
Used by:
Cause: An attempt was made to allocate a fixed feeder as specified by the device comment in question,
but an error occurred when the feeder was checked against the usable feeder types.
Remedy: Change the feeder type in the PST file to one that can be used by the station where the feeder is
specified as fixed.
------------------------------
第 1944 页
Code: 2100753B
Display: "There is insufficient space for a feeder in PT file"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred when the feeder width was checked against the end of the station.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 2100753C
Display: "Space between feeders in PT file is insufficient"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred due to interference between feeders.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 2100753D
Display: "Undefined cartridge name for device in PT file"
Used by:
Cause: The feeder type cannot be determined, because the feeder type has not been entered in the device
comment field of the PST file. The feeder type will be determined based on the Part data.
Remedy: Enter the feeder type in the relevant device comment field of the PST file.
------------------------------
Code: 21007600
Display: Illegal parameter option
Used by:
Cause: The start-up parameter is illegal.
Remedy: When doing direct start up, check and correct the input options.
------------------------------
Code: 21007601
Display: Message file read error
Used by:
Cause: Unable to read the message file.
Remedy: Re-install the software.
------------------------------
Code: 21007602
Display: CRT event link error
Used by:
Cause: Unable to link the CRT event.
Remedy: Re-boot MCS.
------------------------------
Code: 21007603
Display: Part data offset data read error
Used by:
Cause: Unable to read the Part data.
Remedy: This is a Part data format error. Check the Part data file in the Editor, and if the format is
unusual, reconstruct the file. Save the changes.
------------------------------
Code: 21007604
Display: Input program file read error
Used by:
Cause: Unable to read the input program file.
Remedy: Check that the input file can be edited. If it cannot, recreate the file.