FUJI错误代码查询.pdf - 第476页

Fujitrax Verifier will not be able to administer parts correctly. The parameter indicates the target slot number. Remedy: Use a feeder with a different FIDL, or make a new FIDL for the feeder with the duplicated FIDL. --…

100%1 / 5282
Remedy: Resupply parts to the feeder at the target slot.
------------------------------
Code: 12040602
Display: Splicing warning (remaining parts).
Used by:
Cause: The number of parts remaining has reached the splicing low quantity limit.
The parameter indicates the target slot number.
This limit is set in Fujitrax Verifier or at the Handy Terminal.
Remedy: Splice new parts to the feeder at the target slot.
------------------------------
Code: 12040603
Display: Parts out warning (remaining time).
Used by:
Cause: The number of parts remaining has reached the low quantity limit (time).
The parameter indicates the target slot number.
This limit is set in Fujitrax Verifier or using the parts administration functions at the machine.
Remedy: Resupply parts to the feeder at the target slot, or prepare parts for resupply.
------------------------------
Code: 12040604
Display: Splicing limit.
Used by:
Cause: The number of parts remaining has reached the splicing limit.
This error is also a warning for faulty splicing.
The parameter indicates the target slot number.
This limit is set in Fujitrax Verifier or at the Handy Terminal.
Remedy: Carry out verification again for the parts on the feeder at the target slot.
------------------------------
Code: 12040605
Display: Verification incomplete.
Used by:
Cause: The machine attempted to pick-up a part for which verification is not complete.
Verification has not been properly completed.
Communications with Fujitrax Verifier may be in progress.
The parameter indicates the target slot number.
Remedy: Carry out verification using the Handy Terminal.
If communications with Fujitrax Verifier are still in progress,
complete the communications at the device check screen,
and continue production when verification is complete.
------------------------------
Code: 12040606
Display: Device check incomplete
Used by:
Cause: Production cannot commence because the device check has not been completed.
Remedy: Perform verification for any incomplete devices using the device check panel.
------------------------------
Code: 12040632
Display: Duplicate FIDL
Used by:
Cause: An FIDL for a feeder that is already registered for another feeder on the machine has been
submitted.
An FIDL for a feeder loaded on the machine has been duplicated.
第 475 页
Fujitrax Verifier will not be able to administer parts correctly.
The parameter indicates the target slot number.
Remedy: Use a feeder with a different FIDL, or make a new FIDL for the feeder with the duplicated FIDL.
------------------------------
Code: 12040633
Display: Duplicate DID
Used by:
Cause: A DID for a part that is already registered for another part on the machine, has been submitted.
A reel DID loaded on the machine has been duplicated.
Fujitrax Verifier will not be able to administer parts correctly.
The parameter indicates the target slot number.
Remedy: Make a new DID for the parts reel that has the duplicated DID.
------------------------------
Code: 12040634
Display: Statistical device error
Used by:
Cause: The specified error count was reached when performing statistical device skip processing.
The machine was stopped due to a statistical device error.
Remedy: Adjust the feeder or nozzle used for the slot at which the statistical device skip error was issued.
------------------------------
Code: 12040635
Display: Statistical device warning
Used by:
Cause: The specified error count was reached when performing statistical device skip processing.
Remedy: Adjust the feeder or nozzle.
------------------------------
Code: 12042001
Display: "CARTRIDGE NG" (CP), Feeder NG" (CP5), or "FEEDER SET *" (IP2)
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,IP2,IP3
Cause: This is a tape leaf error (an error in the tape feeder error). The tape leaf detection sensor has
been tripped.
Remedy: Check the feeder. Make sure the feeder is properly set on the pallet. Check the tape leaf
detection sensor.
------------------------------
Code: 12042002
Display: "CARTRIDGE NG" (CP), Feeder NG" (CP5), or "FEEDER SET *" (IP2)
Tape leaf sensor error!(NP2,QP3)
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,IP2,IP3,NP2,QP3
Cause: This is a tape leaf error (an error in the tape feeder error). The tape leaf detection sensor has
been tripped.
The tape leaf sensor was triggered.(NP2,QP3)
Remedy: Check the feeder. Make sure the feeder is properly set on the pallet. Check the tape leaf
detection sensor.
Check the condition of the feeders.(NP2,QP3)
------------------------------
Code: 12042003
Display: COMP. UNSET
Used by: CP3
Cause: The parts have not been set (CP3).
Remedy: Set the parts.
------------------------------
第 476 页
Code: 12042004
Display: Tape Feeder 18ST
Used by: CP5
Cause: An improperly positioned feeder activated the tape leaf sensor at station 18.
Remedy: Check the position of the feeders around the tape leaf sensor. If there are any problems,
reposition the feeders.
------------------------------
Code: 12042005
Display: MFU feeder interference error
Used by: QP3
Cause: MFU area sensor is being triggered by the feeder.
Feeder cannot be used due to possible contact problem with the machine.
Remedy: Replace the feeders.
------------------------------
Code: 12042007
Display: Test area remaining capacity warning
Used by: QP3
Cause: Test area capacity has almost been exhausted.
Wipe off the glue dots in the test area.
Execute the test area [Clear] command to set to the initial dispensing point position.
Remedy: Wipe off the glue dots in the test area.
Execute the test area [Clear] command.
------------------------------
Code: 12042008
Display: Test area full
Used by: QP3
Cause: Test area remaining capacity setting has been reached.
Wipe off the glue dots in the test area.
Remedy: Press Ready ON to set dispensing to the initial position.
------------------------------
Code: 12042009
Display: Test area setting error
Used by: QP3
Cause: There is mistake in a test area setting being used.
Check the slot number.
Parameter Item name that should be checked.
Remedy: Check the item .
------------------------------
Code: 1204200A
Display: Test area setting change
Used by: QP3
Cause: Dispensing point in test area has been set to the initial position due to change in test area
setting.
Remedy: Wipe off glue dots in the test area before carrying out operation.
------------------------------
Code: 12044001
Display: Tray eject error
Used by: IP1,IP2
Cause: When the tray was to be unloaded, the tray unloading sensor was not on.
Remedy: If the tray was not unloaded, remove the tray by hand. If the tray was unloaded, check the tray
coordinates set in Part data and adjust the sensor. If this error occurs on the IP1, always enter the