FUJI错误代码查询.pdf - 第817页
------------------------------ Code: 1207E?0D Display: "SCU?(ICM,PMC?) Error Code:********" (QP2) "Machine Stop(SCU Error)" (QP2) Used by: QP242,QP201,QP202,QP203 Cause: The command could not be execu…
------------------------------
Code: 1207E?07
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PMC Reply Time Out" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: A timeout occurred while waiting for a response from the PMC.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure the ARCNET cable is not broken. Check the PMC for problems.
------------------------------
Code: 1207E?08
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Robust Controller Error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Robust controller error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Clear the robust controller error.
------------------------------
Code: 1207E?09
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Flux Controller Error" (QP2)
Used by: QP242
Cause: Flux controller error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Clear the flux controller error.
------------------------------
Code: 1207E?0A
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Safety Door Open" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The machine has executed an emergency stop because a safety door is open.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Close the safety door.
------------------------------
Code: 1207E?0B
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Specified D No Incorrect" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: A nonexistent device number has been specified, resulting in a device number error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Specify the correct device number.
------------------------------
Code: 1207E?0C
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"No Feeder OFF Signal" (QP2)
No Feeder OFF Signal(NP2,QP3)
Used by: QP242,QP201,QP202,QP203,NP2,QP3
Cause: A timeout has occurred while waiting for supply setup completion, resulting in a feeder error.
(value replacing "?" is module number; error code appears in place of asterisks)(QP2)
A timeout has occurred while waiting for supply setup completion, resulting in a feeder
error.(NP2,QP3)
Remedy: Check that the air supply is connected properly, or that the sequencer is operating correctly.
第 816 页
------------------------------
Code: 1207E?0D
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Machine Stop(SCU Error)" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The command could not be executed because the SCU was stopped due to an error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Clear the SCU error, press the RESET switch, and restart the machine.
------------------------------
Code: 1207E?0E
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"No Specified Axis Exists" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The specified axis does not exist.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Specify the desired axis using a proper axis number.
------------------------------
Code: 1207E?0F
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"MTU Not Ready/MTU Locked" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The conditions for tray unit activation where not met. (The tray unit is locked.)
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use inching or another method to clear the tray lock status.
------------------------------
Code: 1207E?10
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"TY Axis Not at Origin" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The shuttle (TY-axis) is not at the origin position.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use inching or another method to set the shuttle at the origin position.
------------------------------
Code: 1207E?11
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Doed Not Exit" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: There is no board on the conveyor.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Set a board on the conveyor. Make sure that the board arrival check sensor is functioning
normally.
------------------------------
Code: 1207E?12
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nozzle Positioning NG" (QP2)
Used by: QP242
Cause: Index-type nozzle positioning error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Rotate the nozzle to the positioning complete position. Make sure that the nozzle positioning
check sensor is functioning normally.
------------------------------
第 817 页
Code: 1207E?13
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Reply Time Out" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The machine was unable to respond to a request from the PMC within the specified time.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?14
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Transfer Time Out" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: A board did not arrive within the specified time, resulting in a board transfer error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure that board transport occurs smoothly. Make sure that the board arrival check sensor
is functioning normally.
------------------------------
Code: 1207E?15
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Transport Mode" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The command could not be executed because a board transport mode was being executed.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?16
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Feeder is Indexing" (QP2)
Feeder is Indexing.(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: The machine stopped while a feeder was indexing.(QP2)
(value replacing "?" is module number; error code appears in place of asterisks)(QP2)
The machine stopped while a feeder was indexing.(NP2,QP3)
Remedy: Use I/O commands or another method to initialize the indexing feeder.
------------------------------
Code: 1207E?17
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"MFU Clamp Error" (QP2)
Used by: QP242
Cause: MFU clamp timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?18
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"MFU Unclamp Error" (QP2)
Used by: QP242
Cause: MFU unclamp timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
第 818 页