FUJI错误代码查询.pdf - 第655页
being set using the I/O operation, the board information will be deleted if the reset-start operation is carried out thereby making it impossible to execute production. Remedy: First confirm whether or not the pallet ID …
Used by: QP132
Cause: There is no space in the internal table used for managing the board information of boards inside
the pallet. This is ordinarily an QP132 software bug.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 1206680D
Display: DATA LOGIC ERROR [1206680D]
Used by: QP132
Cause: There is a contradiction in the QP132 internal data between the pallet management table and the
board management table. A pallet indexing error will occur when either the pallet comes to a halt in the
incorrect position, or when erroneous data is reported by the PMC.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 1206680E
Display: DATA LOGIC ERROR [1206680E]
Used by: QP132
Cause: The PMC could not locate the program being used in production inside the machine. If the
program being used in production is not in the PMC, the PMC will send a request to the machine (main
controller). The QP132 specifications require that the program being used in production must be inside
the machine, therefore program deletion must not be carried out until the final board has been unloaded.
Remedy: Transmit the program.
------------------------------
Code: 1206680F
Display: DATA LOGIC ERROR [1206680F]
Used by: QP132
Cause: Multiple pallet ID number tables were detected in the pallet management table within the QP132
internal data. Either a pallet exists that actually has the same ID or there is a bug in the QP132 software.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. When replacing a damaged pallet, remove the ID plate from the
previous pallet and attach it to the new one. It will not be possible to proceed with operation unless the
error is cleared. If necessary restart normal operation after unloading all boards inside the machine using
the [Flush Out] command.
------------------------------
Code: 12066810
Display: DATA LOGIC ERROR [12066810]
Used by: QP132
Cause: The table for setting the amount of displacement for fiducial marks does not exist. On the
QP132, the board information is saved in the table when the board is loaded, and the pallet ID is saved at
the approach station after the board is loaded. As a result, when a board exists in the pallet loader after
第 654 页
being set using the I/O operation, the board information will be deleted if the reset-start operation is
carried out thereby making it impossible to execute production.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066811
Display: DATA LOGIC ERROR [12066811]
Used by: QP132
Cause: The board information table inside the pallet does not exist. On the QP132, the board
information is saved in the table when the board is loaded, and the pallet ID is saved at the approach
station after the board is loaded. As a result, when a board exists in the pallet loader after being set using
the I/O commands, the board information will be deleted if the reset-start operation is carried out thereby
making it impossible to execute production.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066812
Display: DATA LOGIC ERROR [12066812]
Used by: QP132
Cause: The creation of multiple board management tables in the QP132 internal data was detected. This
error occurs when separate pallets are found to have the same ID, or there is a QP132 software bug.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066813
Display: DATA LOGIC ERROR [12066813]
Used by: QP132
Cause: During operation in the "One board per pallet" mode a pallet with multiple boards was detected.
This is a bug in the QP132 software.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066814
Display: DATA LOGIC ERROR [12066814]
Used by: QP132
第 655 页
Cause: The pallet ID in the report received from the PMC is different from the previous pallet ID. The
pallet ID managed by the PMC is determined at the pallet stopping position and should not change until
the pallet moves during the next circulation. This error will occur if a PMC report mistake is detected, the
SS-axis is inched or if the pallet position is displaced by any circulation of pallets other than the
circulation associated with automatic operation.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066815
Display: DATA LOGIC ERROR [12066815]
Used by: QP132
Cause: This is a malfunction in the software. The buffer was filled without an inquiry being made by
communications packet processing.
Remedy: Cut the power to the machine and then turn it back on. There are also cases where it is
necessary to carry out the flush out operation.
------------------------------
Code: 12066816
Display: DATA LOGIC ERROR [12066816]
Used by: QP132
Cause: The X035: out-conveyor board arrival check sensor (OUT_ARRV_CHK) failed to work correctly. Or
there is a bug in the QP1 software.
Remedy: Carry out a check of the sensor.
------------------------------
Code: 12066817
Display: Same as code
Used by: QP132
Cause: Discontinue.
Remedy: Discontinue.
------------------------------
Code: 12066818
Display: Same as code
Used by: QP132
Cause: The machine has stopped operating because a processing or data inconsistency has been
detected.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
Read] command. Once the SS-axis has been returned to its origin position using the [SS Move] command,
ensure that the error has been cleared. It will not be possible to proceed with operation unless the error is
cleared. If necessary restart normal operation after unloading all boards inside the machine using the
[Flush Out] command.
------------------------------
Code: 12066819
Display: PLT size error [12066819]
Used by: QP132
Cause: Pallet size or pitch information outside specified limits has been detected.
Remedy: First confirm whether or not the pallet ID data has been incorrectly read. In the case where, for
example, an error occurs while indexing, return the pallet to the correct position and execute the [PID
第 656 页