FUJI错误代码查询.pdf - 第1837页

Code: 1D6E8002 Display: Used by: Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not detect any part. Remedy: Re-supply parts. If parts were picked and this error occu…

100%1 / 5282
Cause: Unable to find the edge of the part.
Remedy: Check the part shape, and check the image taken by vision processing.
------------------------------
Code: 1D6E4016
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the part size and orientation.
------------------------------
Code: 1D6E4019
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the part size and orientation.
------------------------------
Code: 1D6E401B
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the part size and orientation.
------------------------------
Code: 1D6E401C
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the part size and orientation.
------------------------------
Code: 1D6E401D
Display:
Used by:
Cause: Unable to find the edge of the part.
Remedy: Check the part shape, and check the image taken by vision processing.
------------------------------
Code: 1D6E401F
Display:
Used by:
Cause: There are too many leads.
Remedy: Check the part shape, and check the image taken by vision processing.
------------------------------
Code: 1D6E4020
Display:
Used by:
Cause: Unable to find the edge of the part.
Remedy: Check the part shape, and check the image taken by vision processing.
------------------------------
Code: 1D6E4021
Display:
Used by:
Cause: Unable to find the edge of the part.
Remedy: Check the part shape, and check the image taken by vision processing.
------------------------------
第 1836 页
Code: 1D6E8002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D6E8100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D6E8110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D6E8111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D6E8112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D6E8113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D6E8114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D6E8115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D6E8120
第 1837 页
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D6E8121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
Remedy: Specify Qty_1.
------------------------------
Code: 1D6E8122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
Remedy: Specify Qty_2.
------------------------------
Code: 1D6E8123
Display:
Used by:
Cause: Qty_3 (the number of leads on the upper side) in Part data has not been specified.
Remedy: Specify Qty_3.
------------------------------
Code: 1D6E82??
Display:
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D6E83??
Display:
Used by:
Cause: The body is too short in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D6E84??
Display:
Used by:
Cause: The body is too long in the Y direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D6E85??
Display:
Used by:
Cause: The body is too short in the Y direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------