touch panel to access the sequence screen, and specify whether recovery selection for the head in question is necessary or not. ------------------------------ Code: 12040113 Display: MTU parts are being supplied. Used by…

100%1 / 5282
Remedy: Resupply the parts.
------------------------------
Code: 1204010B
Display: Recovery limit error!
Used by: NP2,QP3
Cause: The recovery limit has been reached.
Remedy: Clear the cause of the error and press the RESET button.
------------------------------
Code: 1204010C
Display: Parts error for robot 1!
Used by: NP2,QP3
Cause: A cycle stop was executed due to a parts error.
Remedy: Clear the cause of the error and push the RESET button.
------------------------------
Code: 1204010D
Display: Parts out
Used by: QP301
Cause: No available tray.
Remedy: Supply trays or remove empty trays.
------------------------------
Code: 1204010E
Display: Supplying trays
Used by: QP301
Cause: Supplying trays.
Remedy: Complete tray supply and start Auto Production.
------------------------------
Code: 1204010F
Display: Glue level warning.
Used by: QP3
Cause: Syringe glue exhausted.
Remedy: Resupply glue and resume operation.
------------------------------
Code: 12040110
Display: Glue level warning.
Used by: QP3
Cause: Switching to single panel production due to limited glue. The machine will stop when the next
panel is complete.
Remedy: Resupply glue and resume operation.
------------------------------
Code: 12040111
Display: Glue level warning.
Used by: QP3
Cause: Insufficient remaining glue.
Remedy: Resupply glue and resume operation.
------------------------------
Code: 12040112
Display: Recovery selection not specified.
Used by: QP3
Cause: The head at which the insertion error occurred does not perform move as specified when
production is resumed.
Remedy: After verifying the part status for the insertion error, select [Automatic] qG [Sequence] at the
第 467 页
touch panel to access the sequence screen, and specify whether recovery selection for the head in question
is necessary or not.
------------------------------
Code: 12040113
Display: MTU parts are being supplied.
Used by: QP3
Cause: MTU parts are being supplied.
Remedy: After completion of parts supply, press the [SUPPLY COPLT] button.
------------------------------
Code: 12040114
Display: 料尽。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 到达了设定的补件数。
Remedy: 因料尽而使机器停止时,请在补充元件后在重新开始生产。
有元件的时候,请确认吸取状态是否正确。
另外,请检查供料器或者料盘是否正确地安装。
------------------------------
Code: 12040115
Display: 超出最大补件次数
Used by: XP141
Cause: 到达了设定的补件数。
Remedy: 因料尽而使机器停止时,请按下“料尽确认”按键,请在补充元件后在重新开始生产。
有元件的时候,请确认吸取状态是否正确。
另外,请检查供料器是否正确地安装。
------------------------------
Code: 12040201
Display:
Used by:
Cause: A part was dropped.
Remedy: Re-pick the part.
------------------------------
Code: 12040202
Display: Sub nozzle parts drop
Used by: IP1,IP2
Cause: A part was dropped before being set onto the carrier.
Remedy: Check the air pressure, and check the sub-nozzle part detection sensor.
------------------------------
Code: 12040203
Display: Carrier parts drop
Used by: IP2
Cause: A part was dropped while the carrier was in motion.
Remedy: Process the dropped part.
------------------------------
Code: 12040204
Display: "Part dropped during dipping operation"
Used by:
Cause: A component has been dropped during a dipping operation.
Remedy: If a component was dropped in the flux container, adjust the "Dipping_depth", "Dipping_timer",
or "Slow_dipping_speed" parameters. If this error has occurred even though no component was dropped,
make sure that the vacuum sensor is turning on and off normally.
------------------------------
第 468 页
Code: 12040205
Display: Part dropped
Used by: QP3
Cause: Picked part has dropped.
Remedy: Check vacuum pressure of relevant nozzle and part pickup check sensor status.
------------------------------
Code: 12040206
Display:
Used by:
Cause: With the cam at 100 deg. the D axis check could not be finished in the allotted time. Because of
this, when the part is at station 5 it is impossible to determine whether or not the part can be placed
without an error. Therefore, the part is rejected, and recovery is carried out.
Remedy: If this error occurs often, servo adjustment is necessary. Contact Fuji.
------------------------------
Code: 12040207
Display:
Used by:
Cause: With the cam at 100 deg. the vision processing check could not be finished in the allotted time.
Because of this, when the part is at station 5 it is impossible to determine whether or not the part can be
placed without an error. Therefore, the part is rejected, and recovery is carried out.
Remedy: If this error occurs often, servo adjustment is necessary. Contact Fuji.
------------------------------
Code: 12040301
Display: "VACUUM ERROR D??" (IP), "No component on tray" (IP2)
Used by: IP1,IP2
Cause: No component was found at the tray pickup point, or the sensitivity of the tray positioning
sensors require adjustment.
Remedy: Supply the tray with components, then have the machine pick up a component at the pickup
point in question. Adjust the sensors if necessary.
------------------------------
Code: 12040302
Display: "VACUUM ERROR CARRIER" (IP), "Carrier sensor NG" (IP2)
Used by: IP1,IP2,IP3
Cause: The machine cannot pick up the component on the carrier, or the carrier sensor is on even
though the part should have been mounted normally.
Remedy: This error may occur when an incorrect value is set for the component thickness in the Part
data, or when the component is set on the subrobot at the wrong position (due to a tray coordinate error
in the Part data, etc.). Manually place the component on the center of the carrier, then press the RESET
and START buttons. If the machine cannot pickup the part, either try again or manually remove the
component and then press the RESET and START buttons.
------------------------------
Code: 12040303
Display: "No component pick up" (IP2)
Pick-up error!(NP2,QP3)
Used by: IP2,IP3,NP2,QP3
Cause: The machine has determined that a component was not picked up as the result of vision
processing. The machine has been unable to pick up the same component from a tape feeder after
performingthe maximum number of recoveries.
A part detection error occurred during pick-up.(NP2,QP3)
Remedy: Adjust the tape feeder. If the machine has determined that a component wasn't picked up even
though it was, or if this error has failed to occur even though a component was picked up, eitherthe CCD