Cause: System error. Remedy: Cut the power and reboot the machine. If the problem recurs, contact Fuji. ------------------------------ Code: 12063024 Display: Used by: Cause: Even though the head was not over the screen,…

100%1 / 5282
Display:
Used by: GSP5,GP551,GP6
Cause: When the Y- or Z-axis is moving, it interferes with the board holder. Alternately, the board holder
interlock sensor is not working correctly.
Remedy: Retract the board holder so that it does not interfere with the camera station. Also, check the
interlock sensor.
------------------------------
Code: 1206301D
Display:
Used by: GSP5
Cause: The board and the mask expansion rate exceeds the production program's elongation_limit item.
Remedy: Increase the value of the elongation_limit in the production program or change the mask and
board. Alternately, set elongation_limit to 0 and this item will be disabled.
------------------------------
Code: 1206301E
Display:
Used by: GSP5,GP2,GP3
Cause: The screen position compensation was carried out, but the pulse motor moved more than the
value allowed in the Proper data item Max Limit Position ***.
Remedy: Check the mark coordinates in the program. Adjust the screen frame spacers. Check that the
Proper data item Max Limit Position is not set to 0.
------------------------------
Code: 1206301F
Display:
Used by:
Cause: Process timeout occurred during communication.
Remedy: Contact Fuji if this happens frequently.
------------------------------
Code: 12063020
Display:
Used by:
Cause: The stocker data set signal was output, but no reply was received.
Remedy: Check the wiring. Check that the stocker sequencer is operating correctly.
------------------------------
Code: 12063021
Display:
Used by:
Cause: A command was sent to the stocker communication unit but a response was not received within
the specified time limit.
Remedy: Check the wiring. If this error occurs frequently, check the machine version and the stocker
ROM version, and contact Fuji.
------------------------------
Code: 12063022
Display:
Used by: GSP5,GP2,GP3,GP551,GP6
Cause: Communication could not be carried out with the printing measurement machine.
Remedy: Check the wiring between the terminal and the printing measurement machine.
------------------------------
Code: 12063023
Display:
Used by: GSP5
第 616 页
Cause: System error.
Remedy: Cut the power and reboot the machine. If the problem recurs, contact Fuji.
------------------------------
Code: 12063024
Display:
Used by:
Cause: Even though the head was not over the screen, an attempt was made to execute the solder
discharge command.
Remedy: Inch the head over the metal portion of the screen and execute the solder discharge command.
------------------------------
Code: 12063025
Display: Interlock Z
Used by: GSP5
Cause: The camera station may collide with the main table.
Remedy: Inch the Z-axis close to its zero set position (the position at which the Z-axis origin sensor,
Z_AXIS_ZERO, turns on).
------------------------------
Code: 12063026
Display: XL XR Interlock
Used by:
Cause: The L camera and R camera proximity sensor was activated
Remedy: Separate the L and R cameras either manually or by inching.
------------------------------
Code: 12063027
Display: Obstruction In Screen Path
Used by:
Cause: Stencil transport was not possible because of an obstruction in the stencil transport path.
Remedy: Remove the obstruction.
------------------------------
Code: 12063028
Display: 请拆下网板
[Please Screen Release]
Used by: GP551,GP6,GPX,NXTP
Cause: 现在,网板正处于夹紧中。在更换支架时有网板的情况下发生。 存在网板框 (GPX)
Remedy: 请松开网板(指令页 558(2)「松开」),然后拆下。 请将网板框取出。(GPX)
<img src="$LKEY_ERRIMG_MC$/12063028.PNG">
------------------------------
Code: 12063029
Display: "Please Cleaner escape"
Used by: GP551,GP6
Cause: This error occurs if the holder is changed while the cleaner is not at the origin position.
Remedy: Move the cleaner to the origin position (the position at which X05C:CLNR ZERO POS" shows a
value of 0). If necessary, make sure that the lower cleaner origin position check sensor (X05C:CLNRZERO
POS) is functioning normally.
------------------------------
Code: 1206302A
Display: "Cleaner Did Not Connect"
Used by: GP551,GP6
Cause: This error may occur if an attempt is made to close the cleaner head while the connection status
between the cleaner and the cleaner drive axis is inappropriate: either the cleaner notch that connects the
cleaner to the drive axis was not inserted, or the cleaner is not proximate to the drive axis. This error may
第 617 页
also occur if the cleaner notch is out even though the cleaner was not at the escape position.
Remedy: In the former instance, use [HEAD ATTACHMENT] on command page 553-2(4) to properly
connect the cleaner to the drive axis. If necessary, make sure that the lower cleaner connection check
sensor and the cleaner connection position proximity check sensor (X05D:LW CLR CPL CHK and
X03E:CLNR NEAR CHK) are functioning normally. In the latter case, manually return the cleaner to the
origin position.
------------------------------
Code: 1206302B
Display: "Cleaner Sandwich Position Out of Range"
Used by: GP6
Cause: This error occurs if an attempt is made to close the cleaner head while the cleaner is at an
inappropriate position. The cleaner is either at the origin or outside the cleaning range.
Remedy: Move the cleaner inside the cleaning range. On a double-side cleaner, the cleaning range is
between the positions set by the following Proper data parameters: "222:Max Limit Position S clnr"and
"223:Min Limit Position S clnr." On a single-side cleaner, it is between the positions set by the following
Proper data parameters: "232:Max Limit Position Y clnr" and "233:Min Limit PositionY clnr."
------------------------------
Code: 1206302C
Display: "Cleaner Notch Action Error"
Used by: GP6
Cause: Removal of the cleaner notch required longer than the specified time. This error may also occur if
the cleaner notch is in even though the cleaner is not proximate to the cleaner drive axis (the Y-axis for a
double-side cleaner, or the S-axis for a single-side cleaner).
Remedy: Use I/O commands to check the sensor. If necessary, return the cleaner to the proper status.
------------------------------
Code: 1206302D
Display: "Cleaner XY catch"
Used by: GP6
Cause: Removal of the notch connecting the single-side cleaner to the XY-axis required longer than the
specified time.
Remedy: Use I/O commands to check the sensor.
------------------------------
Code: 1206302E
Display: "Move SQG Start Position at Printing"
Used by: GP551,GP6
Cause: This error occurs if automatic operation is started with the double squeegee positioned inside the
printing area.
Remedy: Move the squeegee outside the printing area, either to the front or rear side.
------------------------------
Code: 1206302F
Display: 请除去印刷状态不明的电路板
[Printing Not Possible. Remove Board]
Used by: GPX,NXTP
Cause: 判断出主搬运轨道的电路板正处在印刷途中。印刷途中的电路板不能够印刷。
Remedy: 请除去主搬运轨道的电路板,修正后,从IN搬运轨道处载入。
<img src="$LKEY_ERRIMG_MC$/1206302F.PNG">
------------------------------
Code: 12063030
Display: "Univ holder at inner limit"
Used by: GP551,GP6
Cause: Board holder interference occurred while changing the conveyor width. This error occurs when