FUJI错误代码查询.pdf - 第74页
Cause: There is a device in the TPU original device setting which is not an original device. This error applies to devices 1 to 50. Remedy: Set a correct "OD" value in D_data in the production program. --------…
Display:
Used by:
Cause: The coordinates specified for the Y-axis in placing sequence data are out of range in the -
direction. This error applies to sequences 181 to 200.
Remedy: Set a correct "Y" value in N_data in the production program.
------------------------------
Code: 1101C06A
Display:
Used by:
Cause: The coordinates specified for the Y-axis in placing sequence data are out of range in the -
direction. This error applies to sequences 201 to 220.
Remedy: Set a correct "Y" value in N_data in the production program.
------------------------------
Code: 1101C06B
Display:
Used by:
Cause: The coordinates specified for the Y-axis in placing sequence data are out of range in the -
direction. This error applies to sequences 221 to 240.
Remedy: Set a correct "Y" value in N_data in the production program.
------------------------------
Code: 1101C06C
Display:
Used by:
Cause: The coordinates specified for the Y-axis in placing sequence data are out of range in the -
direction. This error applies to sequences 241 to 260.
Remedy: Set a correct "Y" value in N_data in the production program.
------------------------------
Code: 1101C06D
Display:
Used by:
Cause: The coordinates specified for the Y-axis in placing sequence data are out of range in the -
direction. This error applies to sequences 261 to 280.
Remedy: Set a correct "Y" value in N_data in the production program.
------------------------------
Code: 1101C06E
Display:
Used by:
Cause: The coordinates specified for the Y-axis in placing sequence data are out of range in the -
direction. This error applies to sequences 281 to 300.
Remedy: Set a correct "Y" value in N_data in the production program.
------------------------------
Code: 1101C06F
Display:
Used by:
Cause: The coordinates specified for the Y-axis in placing sequence data are out of range in the -
direction. This error applies to sequences 301 to the final sequence.
Remedy: Set a correct "Y" value in N_data in the production program.
------------------------------
Code: 1101C070
Display:
Used by: IP3
第 73 页
Cause: There is a device in the TPU original device setting which is not an original device. This error
applies to devices 1 to 50.
Remedy: Set a correct "OD" value in D_data in the production program.
------------------------------
Code: 1101C071
Display:
Used by: IP3
Cause: There is a device in the TPU original device setting which is not an original device. This error
applies to devices 51 to 100.
Remedy: Set a correct "OD" value in D_data in the production program.
------------------------------
Code: 1101C072
Display:
Used by: IP3
Cause: There is a device where the TPU unit number setting is not correct. This error applies to
sequences 1 to 50.
Remedy: Set a correct "TU" value in D_data in the production program.
------------------------------
Code: 1101C073
Display:
Used by: IP3
Cause: There is a device where the TPU unit number setting is not correct. This error applies to
sequences 51 to 100.
Remedy: Set a correct "TU" value in D_data in the production program.
------------------------------
Code: 1101C074
Display:
Used by: IP3
Cause: There is a device where the TPU magazine number setting is not correct. This error applies to
sequences 1 to 50.
Remedy: Set a correct "TM" value in D_data in the production program.
------------------------------
Code: 1101C075
Display:
Used by: IP3
Cause: There is a device where the TPU magazine number setting is not correct. This error applies to
sequences 51 to 100.
Remedy: Set a correct "TM" value in D_data in the production program.
------------------------------
Code: 1101C076
Display:
Used by: IP3
Cause: There is a device where the TPU unit number and magazine number match was previously
specified for another device. This error applies to sequences 1 to 50.
Remedy: Check that "TU" and "TM" in D_data in the production program match, and that the data is
correct.
------------------------------
Code: 1101C077
Display:
Used by: IP3
Cause: There is a device where the TPU unit number and magazine number match was previously
第 74 页
specified for another device. This error applies to sequences 51 to 100.
Remedy: Check that "TU" and "TM" in D_data in the production program match, and that the data is
correct.
------------------------------
Code: 1101C078
Display:
Used by: IP3
Cause: The next device has not been specified. This error applies to device numbers 1 to 50.
Remedy: Specify a next device in "Next" in the production program.
------------------------------
Code: 1101C079
Display:
Used by:
Cause: The next device has not been specified. This error applies to device numbers 51 to 100.
Remedy: Specify a next device in "Next" in the production program.
------------------------------
Code: 1101C07A
Display:
Used by:
Cause: The next device has not been specified. This error applies to device numbers 101 to 300.
Remedy: Specify a next device in "Next" in D_Data in the production program.
------------------------------
Code: 1101C07B
Display:
Used by:
Cause: The next device has not been specified. This error applies to device numbers 301 to 500.
Remedy: Specify a next device in "Next" in D_data in the production program.
------------------------------
Code: 1101C07C
Display:
Used by: IP3
Cause: There are over 30 next devices and the loop does not close. This error applies to device numbers
1 to 50.
Remedy: Change the settings in "Next" in the production program so that the loop closes within 30
devices.
------------------------------
Code: 1101C07D
Display:
Used by:
Cause: There are over 30 next devices and the loop does not close. This error applies to device numbers
51 to 100.
Remedy: Change the settings in "Next" in the production program so that the loop closes within 30
devices.
------------------------------
Code: 1101C07E
Display:
Used by:
Cause: There are over 30 next devices and the loop does not close. This error applies to device numbers
101 to 300.
Remedy: Change the settings in "Next" in the production program so that the loop closes within 30
devices.
第 75 页