FUJI错误代码查询.pdf - 第571页

P132,CP-732E,CP-742ME,CP-742E,CP-752E,GPX,NXTP Cause: 基准定位点的读取结果在程序的"mark_area_tolerance"中所设定的范围外。有可能发生定位点的误识别。 Remedy: 请确认基准定位点的读取状态。 请确认"mark_area_tolerance"的值是否被正确地设定了。 <img src="$LKEY_ERRI…

100%1 / 5282
Code: 120540B9
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 120540BA
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 120540BB
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 120540BC
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 12055001
Display: "Cycle Alarm Process time"
Used by:
Cause: The next cycle could not be calculated within the preset time.
Remedy: Press the reset button and start again.
------------------------------
Code: 12055002
Display: "Vision processing timeout"
Used by: CP3,GL2,GL5,GL541,GSP2,GSP3,GP2,GP3,GP551,GP6,IP1,IP2,IP3
Cause: Vision processing was not completed within the specified time. The machine was not able to read
fiducial marks on the board within the set time (approximately 60 seconds).
Remedy: Check the mark data and the Part data. When the machine has difficulty scanning fiducial
marks, check for problems such as the following: inappropriate mark data settings in the production
program; malformation or soiling of fiducial marks on the board; a board clamped in an abnormal
manner; or hardware problems affecting the CCD board, camera, cables, etc.
------------------------------
Code: 12055003
Display:
Used by:
Cause: The system could not save internal memory.
Remedy: Contact Fuji.
------------------------------
Code: 12055004
Display: 定位点检查错误
在区域检查中超出了区域公差值。
Used by: CP4-1,CP4-2,CP4-
3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GP551,GP6,IP1,IP2,IP3,QP242,QP201,QP202,QP203,Q
第 570 页
P132,CP-732E,CP-742ME,CP-742E,CP-752E,GPX,NXTP
Cause: 基准定位点的读取结果在程序的"mark_area_tolerance"中所设定的范围外。有可能发生定位点的误识别。
Remedy: 请确认基准定位点的读取状态。
请确认"mark_area_tolerance"的值是否被正确地设定了。
<img src="$LKEY_ERRIMG_MC$/12055004.PNG">
------------------------------
Code: 12055005
Display: 定位点检查错误
在间距检查中超出了区域公差值。
Used by: CP4-1,CP4-2,CP4-
3,CP6,CP6M,CP65,CP652C,CP642,CP643,GL2,GL5,GP551,GP6,IP1,IP2,IP3,QP242,QP201,QP202,QP203,Q
P132,CP-732E,CP-742ME,CP-742E,CP-752E,GPX,NXTP
Cause: 基准定位点的读取结果在程序的"mark_pitch_tolerance"中所设定的范围外。有可能发生定位点的误识别。
Remedy: 请确认基准定位点的读取状态。
请确认"mark_pitch_tolerance"的值是否被正确地设定了。
<img src="$LKEY_ERRIMG_MC$/12055005.PNG">
------------------------------
Code: 12055006
Display: "Vision processing system alarm" (CP6)
Used by: CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,QP242,QP201,QP202,QP203,NP2,QP3
Cause: This is a timeout error. The results of vision processing have not been returned. There is a
problem in the vision processing system.
Remedy: Restart the machine. Contact Fuji if this problem occurs even after the machine is restarted.
------------------------------
Code: 12055007
Display: "Vision processing command timeout"
Used by: QP132,NP2,QP3
Cause: This is a timeout error. The results of vision processing registration have not been returned.
There is a problem in the vision processing system.
Remedy: Restart the machine.
------------------------------
Code: 12055008
Display: 12055008
Used by: QP132
Cause: After reading the fiducial mark, the board was judged to be misaligned by more than +-1 mm in
the x direction (FQP1).Depending on the PMC stroke, placement may not be possible.
Remedy: Adjust the board position so that its offset is within the tolerance range.
------------------------------
Code: 12055009
Display: Mark offset too large.
Used by: QP132
Cause: The resulting fiducial mark reading shows a mark offset in the X or Y-direction being greater than
+-3 mm.
Remedy: If may not be possible for the PMC to carry out the placement stroke.Adjust the position of the
board so that the board offset is within range.
------------------------------
Code: 12055011
Display: Mark Check Error:Seq_No. Check board condition Excessive mark misalignment. Adjust board
and restart, or unload the board.
Used by: CP643,CP7series,QPseries,NPseries,GL541
Cause: Excessive mark misalignment. The clamped board is misaligned in excess of the acceptable limit.
第 571 页
Remedy: Check that a back-up pin is not contacting parts on the lower surface of the board. Unload the
board if parts are being contacted, otherwise resumu operation after adjusting the position of the board.
------------------------------
Code: 12055012
Display: Vision processing has been aborted.
Used by: NP2,QP3
Cause: The execution of vision processing has been aborted.
Remedy: Restart the machine. Contact Fuji if this problem occurs even after the machine is restarted.
------------------------------
Code: 12055013
Display: Data error!
Used by: NP2,QP3
Cause: Internal data error!
Remedy: Restart the machine.
------------------------------
Code: 12055014
Display: Pre-allocated sequence error!
Used by: NP2,QP3
Cause: Pre-allocated sequence error!
Remedy: Check the production program, unload the PCB and restart the machine.
------------------------------
Code: 12055015
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot create pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
Code: 12055016
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot open pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
Code: 12055017
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot close pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
Code: 12055018
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot change the name of the pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
Code: 12055019
Display: Pressure measurement file error.
Used by: NP-2, QP-3
Cause: Cannot write to the pressure measurement file.
Remedy: Inspect the condition of the hard disk. It may be full or damaged.
------------------------------
第 572 页