CHK shows a value of 0). ------------------------------ Code: 1205610F Display: Interlock (Z|Y) Conveyor Width Clutch Used by: GP551,GP6 Cause: The displayed axis and the conveyor width clutch may collide.This error occu…
Code: 12056109
Display: Interlock S axis SGQ Holder
Used by: GP551,GP6
Cause: The squeegee holder on the S-axis may collide with another part. This error occurs if an attempt
is made to move the S-axis when the squeegee holder is down.
Remedy: Raise the squeegee holder. Alternatively, check the on/off status of the squeegee holder's
raised/lowered position sensors.
------------------------------
Code: 1205610A
Display: "Interlock S axis Cleaner Head"
Used by: GP6
Cause: The S-axis cleaner head and another part are in an interference zone with respect to each other,
or are interfering with each other. This error occurs when an attempt is made to move the S-axis while
the cleaner head is closed.
Remedy: Open the cleaner head (set Y020:LW CLNR OPEN or Y021:TP CLNR OPEN to 0). If necessary,
make sure that the lower and upper cleaner head open limit check sensors (X05A:LW CLR OPN CHK and
X07C:TP CLR OPN CHK) are functioning normally.
------------------------------
Code: 1205610B
Display: "Interlock S axis Supply Solder"
Used by: GP551,GP6
Cause: The solder supplier (SSD-axis) may interfere with the S-axis.This error occurs if the S-axis is
moved while the solder supplier (SSD-axis) is not at the escape position.
Remedy: Move the solder supplier (SSD-axis) to the escape position. If necessary, make sure that the
SSD-axis escape position check sensor is functioning normally.
------------------------------
Code: 1205610C
Display: Interlock S axis Cleaner
Used by: GP551,GP6
Cause: The S-axis may collide with the top cleaner. For GP-5 machines, this error occurs when the top
cleaner is not at its origin position and an attempt is made to move the S-axis. For GP-6 machines, this
error occurs when the notch on a cleaner not joined to the S-axis is engaged and the S-axis is moving.
Remedy: Move the top cleaner to its origin position (GP-5). Disengage the cleaner's notch (GP-6).
Alternatively, check the on/off status of the top cleaner's origin position sensor (GP-5) or the lower
cleaner's joining sensor (GP-6).
------------------------------
Code: 1205610D
Display: Interlock Cleaner Z axis
Used by: GP551,GP6
Cause: The lower cleaner and the Z-axis may collide.This error occurs when the Z-axis is not at the
retract position and the cleaner, joined to its driving axis, is in motion.
Remedy: Move the Z-axis to its retract position. Alternatively, check the on/off status of the Z-axis'
retract position sensor.
------------------------------
Code: 1205610E
Display: "Interlock Cleaner Camera"
Used by: GP6
Cause: The camera (X-axis) is in an interference zone with respect to the cleaner, or is interfering with it.
This error occurs if the cleaner (connected to the S-axis) is moved while the camera (X-axis) is not at the
escape position.
Remedy: Move the X-axis to the X-axis camera escape position (the position at which X03D:X ESC POS
第 585 页
CHK shows a value of 0).
------------------------------
Code: 1205610F
Display: Interlock (Z|Y) Conveyor Width Clutch
Used by: GP551,GP6
Cause: The displayed axis and the conveyor width clutch may collide.This error occurs when the
conveyor width clutch is engaged while the displayed axis is in motion.
Remedy: Disengage the conveyor width clutch. Alternatively, check the on/off status of the conveyor
width clutch's engaged/disengaged sensors.
------------------------------
Code: 12056110
Display: 联锁 Z轴 相机
[Interlock Zaxis Camera]
Used by: GP551,GP6,GPX,NXTP
Cause: Z轴与相机有可能发生了干涉。在Z轴移动时相机不在待机位置的情况下发生。
Remedy: 请将相机移动到待机位置。或者,请确认相机的待机位置确认传感器的ON/OFF动作。
<img src="$LKEY_ERRIMG_MC$/12056110.PNG">
------------------------------
Code: 12056111
Display: Interlock Z axis Cleaner
Used by: GP551,GP6
Cause: The Z-axis and the lower cleaner may collide.This error occurs when the lower cleaner is not at its
origin position and the Z-axis is in motion. On the GP-6, this error occurs when the cleaner shift is not at
its retract position while the Z-axis is in motion.
Remedy: Move the lower cleaner to its origin position. On the GP-6, for one-sided cleaners, move the
cleaner shift to it retract position. Alternatively, check the on/off status of the sensors at the cleaner
origin position and, on the GP-6, the cleaner shift retract position.
------------------------------
Code: 12056112
Display: Interlock SSD axis Cylinder
Used by: GP551,GP6
Cause: The solder supply syringe which is joined to the SSD-axis may collide with another part. This
error occurs when the solder supply syringe is down and an attempt is made to move the SSD-axis.
Remedy: Raise the solder supply syringe. Alternatively, check the on/off status of the up/down sensors
on the syringe.
------------------------------
Code: 12056113
Display: "Please Camera escape"
Used by: GP551,GP6
Cause: The camera (X-axis) and the Z-axis are in an interference zone with respect to each other, or are
interfering with each other. This error occurs if the holder is changed while neither the camera (X-axis) nor
the Z-axis are at their respective escape positions.
Remedy: Move the Z-axis to the Z-axis escape position (the position at which X03C:Z ESC POS CHK
shows a value of 0), or move the camera (X-axis) to its escape position (the position at which X03D:X ESC
POS CHK shows a value of 0). If necessary, make sure that the Z-axis/camera interference prevention
interlock sensor and the X-axis camera escape position check sensor (X03C:Z ESC POS CHK and X03D:X
ESC POS CHK) are functioning normally.
------------------------------
Code: 12056114
Display: "Cleaner Is Engaged"
Used by: GP6
第 586 页
Cause: A cleaner interlock occurred when the cleaner drive axis (the Y-axis for a double-side cleaner, or
the S-axis for a single-side cleaner) was activated. This error occurs if the cleaner drive axis is activated
while the cleaner is connected to the drive axis during command execution or automatic operation.
Remedy: Use [HEAD REMOVAL] on command page 553-2(3) to disconnect the cleaner from the drive axis
(the Y-axis for a double-side cleaner, or the S-axis for a single-side cleaner). If necessary, make sure that
the lower cleaner connection check sensor and the cleaner connection position proximity check sensor
(X05D:LW CLR CPL CHK and X03E:CLNR NEAR CHK) are functioning normally.
------------------------------
Code: 12056115
Display: "Solder Unit Off Origin"
Used by: GP551,GP6
Cause: A solder supply unit interlock occurred when the S-axis was activated. This error occurs if the S-
axis is activated while the solder supply unit is not at the origin position during command execution or
automatic operation.
Remedy: Use [ESCAPE POSITION MOVEMENT] on command page 544(4) to move the solder supply unit
to the original position. If necessary, make sure that the solder supply unit origin position check sensor
(1108:SSD ZERO POS) is functioning normally.
------------------------------
Code: 12056116
Display: "Interlock Cleaner Z"
Used by: GP6
Cause: This error occurs if a cleaner command is executed while the Z-axis is not at the origin position.
Remedy: Move the Z-axis to the Z-axis escape position (the position at which "X03C:Z ESC POS CHK
shows a value of 0). If necessary, make sure that the Z-axis camera interference prevention
interlocksensor (X03C:Z ESC POS CHK) is functioning normally.
------------------------------
Code: 12056117
Display: "Interlock Cleaner X"
Used by: GP6
Cause: This error occurs if a cleaner command is executed while the X-axis is not at the origin position.
Remedy: Use [CAMERA ESCAPE] on command page 550(2) to move the X-axis to the X-axis escape
position (the position at which X03D:X ESC POS CHK shows a value of 0). If necessary, make sure that
the X-axis camera interference prevention interlock sensor (X03D:X ESC POS CHK) is functioning
normally.
------------------------------
Code: 12056118
Display: "Interlock Cleaner SSD"
Used by: GP6
Cause: This error occurs if a cleaner command is executed while the SSD-axis is not at the origin
position.
Remedy: Use [ESCAPE POSITION MOVEMENT] on command page 544(4) to move the SSD-axis to the
SSD-axis escape position (the position at which 1108:SSD ZERO POS shows a value of 0). If necessary,
make sure that the solder supply unit origin position check sensor (1108:SSD ZERO POS) is functioning
normally.
------------------------------
Code: 12056119
Display: "Interlock Cleaner Holder Down"
Used by: GP6
Cause: This error occurs if a cleaner command is executed while the squeegee holder is down.
Remedy: Raise the squeegee (set Y02F:SQG HLDR UP to 0). If necessary, make sure that the squeegee
holder upper limit check sensor (X070:SQG HLDR UP) is functioning normally.