FUJI错误代码查询.pdf - 第58页
can only be carried out using holder 1 or 4. This error occurs in sequence 751 to 875. Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this part (even if the part does no…
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C01
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 126 to 250.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C02
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 251 to 375.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C03
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 376 to 500.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C04
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 501 to 625.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C05
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 626 to 750.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C06
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
第 57 页
can only be carried out using holder 1 or 4. This error occurs in sequence 751 to 875.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C07
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 876 to 1000.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C08
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1001 to 1125.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C09
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1126 to 1250.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C0A
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1251 to 1375.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C0B
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1376 to 1500.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C0C
第 58 页
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1501 to 1625.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C0D
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1626 to 1750.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C0E
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1751 to 1875.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C0F
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1876 to 2000.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11012001
Display: Same as code
Used by: GP551,GP6
Cause: An incorrect quantity of mark sequences has been included. There is only one board fiducial
sequence or mask fiducial sequence. Two or more sequences are required for proper execution of
compensation.
Remedy: Make sure that the production program contains an appropriate number of fiducial sequences.
As an exception to this rule, the program can be transmitted when neither board fiducial sequencesnor
mask fiducial sequences are present.
------------------------------
Code: 1101B000
Display: ***是范围出错。
Used by: XP141,XP241,XP341,XP142,XP242,GPX,NXTP
Cause: 在生产程序数据项目中设定了超过输入范围的数值。
Remedy: 请修正成输入范围内的数值。
------------------------------