FUJI错误代码查询.pdf - 第2308页

------------------------------ Code: 52??1550 Display: There is "UNIT", "NOZZLE". Used by: Cause: There is a "UNIT", "NOZZLE" entry in the specified production program even though …

100%1 / 5282
error is detected.
Remedy: Check the setting for "UNIT", "NOZZLE" - "BLOCK", "HEADER-" in the production program.
------------------------------
Code: 52??1523
Display: No machine-type "BLOCK" in "UNIT", "NOZZLE".
Used by:
Cause: The machine-type block was not found in "UNIT", "NOZZLE" in the specified production program.
This report is made when the nozzle data and the production program are in the same file and the above
error is detected. When downloading, the nozzle data takes its default values.
Remedy: Check the setting for the machine-type "BLOCK" in "UNIT", "NOZZLE" in the production
program.
------------------------------
Code: 52??1524
Display: "UNIT", "NOZZLE" - "BLOCK", "HEADER-" format error.
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and a format error was detected
in "BLOCK", "HEADER-". This report is made when the nozzle data and the production program are in the
same file and the above error is detected.
Remedy: Check the setting for "UNIT", "NOZZLE" - "BLOCK", "HEADER" in the production program.
------------------------------
Code: 52??1525
Display: "UNIT", "NOZZLE" machine-type "BLOCK" format error.
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and a format error was detected
in the machine-type "BLOCK". This report is made when the nozzle data and the production program are
in the same file and the above error is detected.
Remedy: Check the setting for machine-type "BLOCK" in "UNIT", "NOZZLE" in the production program.
------------------------------
Code: 52??1530
Display: No item definition line for machine-type "BLOCK" in "UNIT", "NOZZLE".
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and the machine-type "BLOCK"
item definition line was not found.
Remedy: Check the setting for the item definition line for the machine-type "BLOCK" in the production
program's "UNIT", "NOZZLE".
------------------------------
Code: 52??1531
Display: "GCCNN" item not defined.
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and a description for "GCCNN" in
the item declaration line in the machine-type "BLOCK" was not found.
Remedy: Check the setting for "GCCNN" in the item declaration line for the machine-type "BLOCK" in
"UNIT", "NOZZLE" in the production program. "GCCNN" is a mandatory item.
------------------------------
Code: 52??1532
Display: "GNAMN"item not defined.
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and a description for "GNAMN"
in the item declaration line in the machine-type "BLOCK" was not found.
Remedy: Check the setting for "GNAMN" in the item declaration line for the machine-type "BLOCK" in
"UNIT", "NOZZLE" in the production program. "GNAMN" is a mandatory item.
第 2307 页
------------------------------
Code: 52??1550
Display: There is "UNIT", "NOZZLE".
Used by:
Cause: There is a "UNIT", "NOZZLE" entry in the specified production program even though "UNIT",
"NOZZLE" was specified as being separate. At downloading, the "UNIT", "NOZZLE" entry in the program is
ignored.
Remedy: Check the "UNIT", "NOZZLE" setting in the production program and the "FILESTRUCT" setting in
"UNIT", "STRUCT".
------------------------------
Code: 52??1551
Display: "UNIT", "NOZZLE" is repeated.
Used by:
Cause: "UNIT", "NOZZLE" is repeated in the production program. When downloading, the first "UNIT",
"NOZZLE" is valid.
Remedy: Check the setting for "UNIT", "NOZZLE" in the production program.
------------------------------
Code: 52??1552
Display: Cannot find nozzle file setting line.
Used by:
Cause: The line for setting the nozzle file at "GNAN" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD" in the
specified production program has been omitted. When downloading, the nozzle data takes its default
values.
Remedy: Check the setting for "GNAN" in the production program.
------------------------------
Code: 52??1553
Display: Multiple nozzle file setting lines.
Used by:
Cause: There are multiple setting lines at "GNAN" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD" in the
specified production program. When downloading, the final line is taken to be the valid one.
Remedy: Check the setting for "GNAN" in the production program.
------------------------------
Code: 52??1554
Display: Nozzle file name omitted.
Used by:
Cause: At the "GNAN" line in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD" in the specified production
program, the nozzle file setting is "" or it has been omitted. When downloading, the nozzle data takes its
default values.
Remedy: Check the setting for "GNAN" in the production program.
------------------------------
Code: 52??1555
Display: Setting for nozzle file name is too long.
Used by:
Cause: The nozzle file setting which is entered at "GNAN" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD"
in the specified production program is too long. The file name is abbreviated to its maximum length when
downloaded.
Remedy: Check the "GNAN" setting in the production program.
------------------------------
Code: 52??1560
Display: Data value in "GCCNN" is out of range.
Used by:
第 2308 页
Cause: The data in the "GCCNN" item in the machine-type "BLOCK" in nozzle data is out of range. When
downloading, the corresponding data line is ignored.
Remedy: Check the setting for the "GCCNN" item in the machine-type "BLOCK".
------------------------------
Code: 52??1561
Display: Data value in"GNAMN"is out of range.
Used by:
Cause: The data in the "GNAMN" item in the machine-type "BLOCK" in nozzle data is out of range. When
downloading, the corresponding data line is ignored.
Remedy: Check the setting for the "GNAMN" item in the machine-type "BLOCK".
------------------------------
Code: 52??1600
Display: No part data file.
Used by:
Cause: The part data file which is referred to in the specified production program was not found. This
report is made when the part data and the production program are in different files and the above error is
detected.
Remedy: Check the setting for "GUTPDN" in "BLOCK", "DEVICE+" in the production program.
Furthermore, check that the file is in the part data directory.
------------------------------
Code: 52??1601
Display: Part data file is in use.
Used by:
Cause: The part data file which is referred to in the specified production program is being used. This
report is made when the part data and the production program are in different files and the above error is
detected.
Remedy: Wait until the file is not being used and then re-execute.
------------------------------
Code: 52??1602
Display: No authorization for part data file.
Used by:
Cause: There is no access authorization for the part data file referred to in the specified production
program. This report is made when the part data and the production program are in different files and the
above error is detected.
Remedy:
------------------------------
Code: 52??1603
Display: Part data file could not be opened.
Used by:
Cause: The part data file referred to in the specified production program could not be opened. This
report is made when the part data and the production program are in different files and the above error is
detected.
Remedy:
------------------------------
Code: 52??1604
Display: No "UNIT", "STRUCT" in part data file.
Used by:
Cause: There is no "UNIT", "STRUCT" in the part data file referred to in the specified production program.
This report is made when the part data and the production program are in different files and the above
error is detected.
Remedy: Check the settings for "UNIT", "STRUCT" in the part data file referred to in the production
第 2309 页