FUJI错误代码查询.pdf - 第2140页
Used by: Cause: The tray dimensions are outside the permissible XP tray specifications (4.00mm - 25.40mm). Remedy: Remedy: Input a permissible tray thickness (4.00mm - 25.40mm). ------------------------------ Code: 2300E…
Used by:
Cause: "Tray" is specified as the packaging type, but the "Tray Row Quantity" item is set to "0".
Remedy: When using the "Tray" packaging type, specify a "Tray Row Quantity" setting of 1 or higher.
------------------------------
Code: 2300E5D4
Display: Tray Length is not correct. Can't eject tray.
Used by:
Cause: The length of the tray to be unloaded (Tray Type 0 or 2) is set as smaller than the remover.
Remedy: Specify a "Tray Length" setting of 72 or higher.
------------------------------
Code: 2300E5D5
Display: Tray Width is not correct. Can't eject tray.
Used by:
Cause: The width of the tray to be unloaded (Tray Type 0 or 2) is set as smaller than the remover.
Remedy: Specify a "Tray Width" setting of 83 or higher.
------------------------------
Code: 2300E5D6
Display: Tray Dump Pick Position X is not correct. Can't eject tray.
Used by:
Cause: The remover (nozzle used to unload trays) protrudes beyond the tray in the X-direction when
picking up a tray.
Remedy: Specify the "Tray Dump Pick Position X" setting so that the remover does not protrude beyond
the tray in the X-direction when picking up trays. (Setting value should satisfy the following equation.)
72 / 2 =< [Tray Dump Pick Position X] x (-1) =< [Tray Width] - (72 / 2)
------------------------------
Code: 2300E5D7
Display: Tray Dump Pick Position Y is not correct. Can't eject tray.
Used by:
Cause: The remover (nozzle used to unload trays) protrudes beyond the tray in the Y-direction when
picking up trays.
Remedy: Specify the "Tray Dump Pick Position Y" setting so that the remover does not protrude beyond
the tray in the Y-direction when picking up trays. (Setting value should satisfy the following equation.)
83 / 2 =< [Tray Dump Pick Position Y] =< [Tray Width] - (83 / 2)
------------------------------
Code: 2300E5D8
Display: The pick up point for the last tray parts exceeds the tray size in the X-direction.
Used by:
Cause: The final pickup position for tray parts exceeds the tray's X-direction size.
Remedy: Specify a setting value which satisfies the following equation.
[Tray Length] => { [Tray First Pickup Position X] x (-1) } + { [Tray Column Pitch] x ( [Tray Column Quantity]
- 1) }
------------------------------
Code: 2300E5D9
Display: The pick up point for the last tray parts exceeds the tray size in the Y-direction.
Used by:
Cause: The final pickup position for tray parts exceeds the tray's Y-direction size.
Remedy: Specify a setting value which satisfies the following equation.
[Tray Width] => [Tray First Pickup Position Y] + [Tray Row Pitch] x ( [Tray Row Quantity] - 1 )
------------------------------
Code: 2300E5DA
Display: Tray cannot be removed. Input the tray thickness (4.00mm - 25.40mm).
第 2139 页
Used by:
Cause: The tray dimensions are outside the permissible XP tray specifications (4.00mm - 25.40mm).
Remedy: Remedy: Input a permissible tray thickness (4.00mm - 25.40mm).
------------------------------
Code: 2300E5DB
Display: Set [Tray Length] to 95.00 mm or more when using the power remover.
Used by:
Cause: The power remover cannot be used to eject trays if the "Tray Length" setting is less than 95.00
mm.
(Only the standard remover can be used)
Remedy: When using the power remover, set "Tray Length" to 95.00 mm or more.
------------------------------
Code: 2300E5DC
Display: Set [Tray Width] to 95.00 mm or more when using the power remover.
Used by:
Cause: The power remover cannot be used to eject trays if the "Tray Width" setting is less than 95.00
mm.
(Only the standard remover can be used)
Remedy: When using the power remover, set "Tray Width" to 95.00 mm or more.
------------------------------
Code: 2300E5DD
Display: The current [Tray Dump Pick Position X] setting is incorrect when using the power remover.
Used by:
Cause: The power remover cannot be used to eject trays with the specified "Tray Dump Pick Position X"
setting.
(Only the standard remover can be used)
Remedy: When using the power remover, set "Tray Dump Pick Position X" so that the remover picks up
the tray at the correct position.
(Use the following formula to set the correct value.)
95 / 2 =< [Tray Dump Pick Position X] x (-1) =< [Tray Length] - (95 / 2)
------------------------------
Code: 2300E5DE
Display: The current [Tray Dump Pick Position Y] setting is incorrect when using the power remover.
Used by:
Cause: The power remover cannot be used to eject trays with the specified "Tray Dump Pick Position Y"
setting.
(Only the standard remover can be used)
Remedy: When using the power remover, set "Tray Dump Pick Position Y" so that the remover picks up
the tray at the correct position.
(Use the following formula to set the correct value.)
95 / 2 =< [Tray Dump Pick Position Y] =< [Tray Width] - (95 / 2)
------------------------------
Code: 23040005
Display: A feeder does not exist in the slot referred to in the sequence.
Used by:
Cause: A feeder does not exist in the slot referred to in the sequence.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 23040006
Display: Part data referred to by the sequence slot does not exist.
Used by:
第 2140 页
Cause: The Part data, referred to by a sequence slot that contains no skipped board/feeder/sequence
setting, does not exist.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 23040008
Display: No feeder exists in the slot referenced by this skipped sequence (for skipped sequences included
in optimization).
Used by:
Cause: A feeder does not exist in a sequence slot that contains board/feeder/sequence skip settings.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 2304000A
Display: Part data referred to by the skip sequence does not exist. This error can be avoided by selecting
[Lines to Skip are Removed] when you optimize.
Used by:
Cause: The part data referred to by a sequence slot containing board/feeder/sequence skip settings does
not exist.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 2304000D
Display: The Alt. Feeder does not exist. Do you want to set 0 for alternate feeder?
Used by:
Cause: A feeder is not set in the alternate feeder specified for the displayed stage-slot.
Remedy: The Feeder Setup information in the program file is incorrect. Check the settings.
------------------------------
Code: 2304000E
Display: There are too many feeders allocated to one stage.
Used by:
Cause: When automatic feeder arrangement was selected at the Optimize Condition settings screen, the
number of feeders allocated to the stage exceeded the maximum feeder slots.
Remedy: Firstly, try changing the [Use feeder type] settings. If unsuccessful, perform optimization using
the [Alt. Feeders are Removed] setting. If still unsuccessful, reduce the part varieties used in the program.
------------------------------
Code: 23040010
Display: Part data referred to by the unused feeders in the [Fix Feeder Slots] does not exist. (Even for
unused feeder(s) without part data, it can't be determined whether the feeder is set at the machine.) This
error can be avoided by selecting [Automatic Most Suitable Feeder Arrangement] when you optimize.
Used by:
Cause: There is no part data displayed in the Feeder Setup.
Remedy: The program file data is incorrect. Check the contents.
------------------------------
Code: 23040012
Display: The slot number does not exist at the machine. This error can be avoided by selecting [Automatic
Most Suitable Feeder Arrangement] when you optimize.
Used by:
Cause: The specified stage - slot number does not exist.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 23040015
第 2141 页