FUJI错误代码查询.pdf - 第736页
Cause: The specified angle for the Q-axis is outside the acceptable range. Remedy: This error does not usually occur. ------------------------------ Code: 12070?7D Display: "ICM(PMC?,SCU?) Error Code:********" …
(CTL) There are no storage trays or, the unloading elevator is full.
Remedy: (APL) Load supply trays or remove the empty trays.
(CTL) Load storage trays or remove the finished trays.
------------------------------
Code: 12070?76
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Parts lost from nozzle" (QP2)
Used by: QP201,QP202
Cause: Parts lost from nozzle.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Place lost parts onto the tray.
------------------------------
Code: 12070?77
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Parts pick-up error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Failed to pick-up the part.
Remedy: Check the parts supply.
------------------------------
Code: 12070?78
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Parts placement error" (QP2)
Used by: QP242, QP202,QP203
Cause: Failed to place part.
Remedy: Check to see if the head is holding a part.
------------------------------
Code: 12070?79
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Cannot move Z-axis, Q-axis outside its movement range." (QP2)
Used by: QP202,QP203
Cause: The Z-axis cannot be moved because the Q-axis is outside its acceptable movement range.
Remedy: Correct the angle of the Q-axis by up to +-15 deg..
------------------------------
Code: 12070?7A
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Cannot move Q-axis, Z-axis outside its movement range." (QP2)
Used by: QP202
Cause: The Q-axis cannot be rotated because the Z-axis is outside its acceptable movement range.
Remedy: Adjust the height of the Z-axis so that it is above the height of the arch motion limit.
------------------------------
Code: 12070?7B
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Cannot move Q-axis as it is outside its rotation range."
Used by: QP202,QP203
Cause: The Q-axis cannot be rotated because it is outside its rotation range.
Remedy: Correct the angle of the Q-axis by up to +-15 deg.
------------------------------
Code: 12070?7C
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Specified angle is outside Q-axis rotation range." (QP2)
Used by: QP202,QP203
第 735 页
Cause: The specified angle for the Q-axis is outside the acceptable range.
Remedy: This error does not usually occur.
------------------------------
Code: 12070?7D
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Mech chuck is holding part. Cannot carry out zero set." (QP2)
Used by: QP202
Cause: Zero setting cannot be carried out because the mechanical chuck is holding a part.
Remedy: Remove the part from the mechanical chuck.
------------------------------
Code: 12070?7E
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Mech chuck is holding part. Cannot carry out inching" (QP2)
Used by: QP202,QP203
Cause: Inching cannot be carried out because the mechanical chuck is holding a part.
Remedy: Remove the part from the mechanical chuck.
------------------------------
Code: 12070?7F
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Failed to check for part." (QP2)
Used by: QP202
Cause: The check for a part on the mechanical chuck failed because only one of the part check sensors is
ON.
Remedy: If there is a part on the chuck,remove it and turn the vacuum off. if there is no part on the
chuck, the parts confirmation sensor may have mistaken part of the machine for a part. Move the placing
head to its retract position. If the same error persists, the part confirmation sensor may require
adjestment.
------------------------------
Code: 12070?80
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No PMC Parameter" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: No PMC parameters exist.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Retransmit the Proper data from the host computer.
------------------------------
Code: 12070?81
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Unaccepted(Servo Not Ready)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132,NP132,NP133
Cause: The command could not be executed because the servo was not ready.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: If this error has occurred while another error is in effect, clear the cause of that error then press
the RESET switch and restart the machine. If this error recurs, determine the reason that servo power is
not being supplied to the PMC.
------------------------------
Code: 12070?82
第 736 页
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Unaccepted(PMC Error)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command could not be executed because the machine is stopped due to a PMC error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, then use commands to dump parts. If the problem
occurs again, use a reset-start to transmit the control software to the PMCs. If the problem occurs again,
faulty hardware such as the PMC control board, servo amps or servo boards may be the cause.
------------------------------
Code: 12070?83
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Sequence Number Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Sequence number error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMC. If the problem is recurring, issues such as a
faulty production program or PMC control board may be the cause.
The maximum number of sequences per production program is 5000, and the maximum number of
sequences for a PLM (PM), including mark sequences is 1000.
------------------------------
Code: 12070?84
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Seq Rationality Check Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Sequence rationality check error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the production program, and execute flush out processing. If the problem occurs again,
retransmit the control software to the PMCs
------------------------------
Code: 12070?85
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Req Command (ST Not Conect)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A handy terminal command request was issued even though there is no handy terminal
connected.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?86
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
第 737 页