FUJI错误代码查询.pdf - 第729页
"Unaccepted Due to Err Stop" (QP2) PM?? ERROR Code:******** (QP132) Used by: QP242,QP201,QP202,QP203,QP132 Cause: A request could not be executed because it was received while the machine was stopped due to an …
Code: 12070?4D
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Parameter" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Valid parameters have not been transmitted to the module that caused the error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Retransmit the Proper data from the host computer.
------------------------------
Code: 12070?4E
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Unaccepted(Parameter Trans)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A request could not be executed because it was received during parameter transmission.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause. If this problem occurs regularly, output trace data from the
machine and send it to Fuji for analysis.
------------------------------
Code: 12070?4F
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Unexecutable(prog Trans'g)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A request could not be executed because it was received during program transmission.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause. If this problem occurs regularly, output trace data from the
machine and send it to Fuji for analysis.
------------------------------
Code: 12070?51
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Command Unaccepted(VPing)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A request could not be executed because it was received during vision processing.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause. If this problem occurs regularly, output trace data from the
machine and send it to Fuji for analysis.
------------------------------
Code: 12070?52
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
第 728 页
"Unaccepted Due to Err Stop" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A request could not be executed because it was received while the machine was stopped due to
an error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?53
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Multiple Command Unaccepted" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A multiple-operation command was not recognized while operating in manual mode.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?55
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong Mode / Not Auto Mode" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A command that must be received during automatic operation has been received while in some
other mode.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?56
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong Mode / In Auto Mode" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A command that must be received while in a mode other than automatic operation has been
received during automatic operation.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?57
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
第 729 页
"No Nozzle Specified in PD" (QP2)
Used by: QP242
Cause: The Proper data does not contain settings for the nozzle specified by the Part data.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the nozzle data in the Device data and the Proper data for the module the caused the
error.
------------------------------
Code: 12070?58
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Desired NSS Occupied" (QP2)
Used by: QP242
Cause: The desired nozzle select station storage location is not available.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the head nozzle and the head nozzle number, then either remove the nozzle from the
desired nozzle select station storage location, or change the head nozzle number.
------------------------------
Code: 12070?59
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Nozzle Orgn Sensor Error" (QP2)
Used by: QP242
Cause: The nozzle check sensor at the nozzle select station is not functioning.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: If the nozzle in question is an index nozzle, the nozzle has not been rotated sufficiently. If it is a
single nozzle, the machine has failed to detect a dropped nozzle. Replace the nozzle in its proper position,
then make sure the nozzle check sensor is functioning normally.
------------------------------
Code: 12070?5A
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Nozzle Check sensor Error" (QP2)
Used by: QP242
Cause: The result of a nozzle check was erroneous.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the head nozzle and the head nozzle number. Make sure the nozzle check sensor is
functioning normally.
------------------------------
Code: 12070?5B
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Operating with Inching Box" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The machine has received a request appropriate to automatic operation or another mode while
being operated from the inching box.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Start automatic operation when inching is complete. If the problem occurs again, use a reset-
start to transmit the control software to the PMC. If the problem is recurring, issues such as a faulty PMC
control board may be the cause.
------------------------------
Code: 12070?5C
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Can't Exe Due to Servo Off" (QP2)
第 730 页