FUJI错误代码查询.pdf - 第2309页
Cause: The data in the "GCCNN" item in the machine-type "BLOCK" in nozzle data is out of range. When downloading, the corresponding data line is ignored. Remedy: Check the setting for the "GCCNN&…
------------------------------
Code: 52??1550
Display: There is "UNIT", "NOZZLE".
Used by:
Cause: There is a "UNIT", "NOZZLE" entry in the specified production program even though "UNIT",
"NOZZLE" was specified as being separate. At downloading, the "UNIT", "NOZZLE" entry in the program is
ignored.
Remedy: Check the "UNIT", "NOZZLE" setting in the production program and the "FILESTRUCT" setting in
"UNIT", "STRUCT".
------------------------------
Code: 52??1551
Display: "UNIT", "NOZZLE" is repeated.
Used by:
Cause: "UNIT", "NOZZLE" is repeated in the production program. When downloading, the first "UNIT",
"NOZZLE" is valid.
Remedy: Check the setting for "UNIT", "NOZZLE" in the production program.
------------------------------
Code: 52??1552
Display: Cannot find nozzle file setting line.
Used by:
Cause: The line for setting the nozzle file at "GNAN" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD" in the
specified production program has been omitted. When downloading, the nozzle data takes its default
values.
Remedy: Check the setting for "GNAN" in the production program.
------------------------------
Code: 52??1553
Display: Multiple nozzle file setting lines.
Used by:
Cause: There are multiple setting lines at "GNAN" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD" in the
specified production program. When downloading, the final line is taken to be the valid one.
Remedy: Check the setting for "GNAN" in the production program.
------------------------------
Code: 52??1554
Display: Nozzle file name omitted.
Used by:
Cause: At the "GNAN" line in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD" in the specified production
program, the nozzle file setting is "" or it has been omitted. When downloading, the nozzle data takes its
default values.
Remedy: Check the setting for "GNAN" in the production program.
------------------------------
Code: 52??1555
Display: Setting for nozzle file name is too long.
Used by:
Cause: The nozzle file setting which is entered at "GNAN" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD"
in the specified production program is too long. The file name is abbreviated to its maximum length when
downloaded.
Remedy: Check the "GNAN" setting in the production program.
------------------------------
Code: 52??1560
Display: Data value in "GCCNN" is out of range.
Used by:
第 2308 页
Cause: The data in the "GCCNN" item in the machine-type "BLOCK" in nozzle data is out of range. When
downloading, the corresponding data line is ignored.
Remedy: Check the setting for the "GCCNN" item in the machine-type "BLOCK".
------------------------------
Code: 52??1561
Display: Data value in"GNAMN"is out of range.
Used by:
Cause: The data in the "GNAMN" item in the machine-type "BLOCK" in nozzle data is out of range. When
downloading, the corresponding data line is ignored.
Remedy: Check the setting for the "GNAMN" item in the machine-type "BLOCK".
------------------------------
Code: 52??1600
Display: No part data file.
Used by:
Cause: The part data file which is referred to in the specified production program was not found. This
report is made when the part data and the production program are in different files and the above error is
detected.
Remedy: Check the setting for "GUTPDN" in "BLOCK", "DEVICE+" in the production program.
Furthermore, check that the file is in the part data directory.
------------------------------
Code: 52??1601
Display: Part data file is in use.
Used by:
Cause: The part data file which is referred to in the specified production program is being used. This
report is made when the part data and the production program are in different files and the above error is
detected.
Remedy: Wait until the file is not being used and then re-execute.
------------------------------
Code: 52??1602
Display: No authorization for part data file.
Used by:
Cause: There is no access authorization for the part data file referred to in the specified production
program. This report is made when the part data and the production program are in different files and the
above error is detected.
Remedy:
------------------------------
Code: 52??1603
Display: Part data file could not be opened.
Used by:
Cause: The part data file referred to in the specified production program could not be opened. This
report is made when the part data and the production program are in different files and the above error is
detected.
Remedy:
------------------------------
Code: 52??1604
Display: No "UNIT", "STRUCT" in part data file.
Used by:
Cause: There is no "UNIT", "STRUCT" in the part data file referred to in the specified production program.
This report is made when the part data and the production program are in different files and the above
error is detected.
Remedy: Check the settings for "UNIT", "STRUCT" in the part data file referred to in the production
第 2309 页
program.
------------------------------
Code: 52??1605
Display: Part data file structure error.
Used by:
Cause: A format error was discovered in "UNIT", "STRUCT" in the part data file referred to in the specified
production program. This report is made when the part data and the production program are in different
files and the above error is detected.
Remedy: Check the settings for "UNIT", "STRUCT" in the part data file referred to in the production
program.
------------------------------
Code: 52??1606
Display: Not a part data file.
Used by:
Cause: The part data file referred to in the production program is not part data. This report is made
when the part data and the production program are in different files and the above error is detected.
Remedy: Check the setting for "FILETYPE", "FILESTRUCT" in "UNIT", "STRUCT" - "BLOCK", "HEADER-" in
the part data file referred to in the specified production program.
------------------------------
Code: 52??1607
Display: Part data file read error.
Used by:
Cause: The part data file referred to in the specified production program was read and an error occurred.
This report is made when the part data and the production program are in different files and the above
error is detected.
Remedy: Check the part data file referred to in the production program.
------------------------------
Code: 52??1610
Display: No "FILETYPE" entry in part data file.
Used by:
Cause: There is no "FILETYPE" entry in "UNIT", "STRUCT" - "BLOCK", "HEADER-" in the specified part
data file.
Remedy: "FILETYPE" is a mandatory item.
------------------------------
Code: 52??1611
Display: No "FILESTRUCT" entry in part data file.
Used by:
Cause: There is no "FILESTRUCT" entry in "UNIT", "STRUCT" - "BLOCK", "HEADER-" in the specified part
data file.
Remedy: "FILESTRUCT" is a mandatory item.
------------------------------
Code: 52??1612
Display: No "UNIT", "PARTS" in part data file or "UNIT", "PARTS" is not at the correct position.
Used by:
Cause: The part data file referred to in the specified production program was read and "UNIT", "PARTS"
was not found or "UNIT", "PARTS" does not follow the correct unit. This report is made when the part data
and the production program are in different files and the above error is detected.
Remedy: Check the setting for "UNIT", "PARTS" in the part data file referred to in the production program.
Furthermore, check the setting for the "UNIT" line prior to "UNIT", "PARTS".
------------------------------
Code: 52??1613
第 2310 页