FUJI错误代码查询.pdf - 第2170页
------------------------------ Code: 230600A3 Display: Optimization cannot be performed if there are less than two active fiducial marks. Used by: Cause: Optimization cannot be performed for programs containing less than…
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle Arrangement] method. If using [Automatic Optimized
Nozzle Arrangement], check the Nozzle Spec. file, or check the Nozzle Name
(PARTS/ENVDT/XP341ENVDT-/PENNZN) in the part data.
------------------------------
Code: 23060047
Display: The Alt. Feeder number must be set to a different slot. Set the Alt. Feeder to 0?
Used by:
Cause: A Alt. Feeder number has been set for the same slot.
Remedy: In the program file's Feeder Setup settings, and change the Alt. Feeder number
(PROGRAM/DEVICE+/GUTNSLTN) to 0 (No Alt. Feeder) or to another slot number.
------------------------------
Code: 23060048
Display: A Alt. Feeder is duplicated, or two or more first slots (reference slot) have been specified for the
same alternate feeder loop. The Alt. Feeder settings will be deleted.
Used by:
Cause: Two or more alternate feeder loops may be overlapping.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2306004A
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop?
Used by:
Cause: When arriving at a alternate feeder, a loop did not exist. The Alt. Feeder setting is zero.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2306004B
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop?
Used by:
Cause: When arriving at a alternate feeder, a non-existent Alt. Feeder setting was found.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2306004C
Display: Nozzle name is not specified. Assume as a standard nozzle?
Used by:
Cause: In the Nozzle folder information file, the Nozzle name is not specified for "GNANAM".
Remedy: When [Yes] is selected, standard Nozzle name is specified according to the diameter. When [No]
is selected, no Nozzle is specified to the Nozzle folder.
------------------------------
Code: 230600A1
Display: The source program is already in an optimized condition. It is not possible to further optimize the
source program.
Used by:
Cause: The post-optimized theoretical cycle time is slower than the pre-optimized time, however, source
program sequence or feeder setup problems have been fixed.
Remedy: It may be possible to achieve a better cycle time result by changing the optimization conditions,
if production constraints allow.
第 2169 页
------------------------------
Code: 230600A3
Display: Optimization cannot be performed if there are less than two active fiducial marks.
Used by:
Cause: Optimization cannot be performed for programs containing less than two active fiducial marks,
including skipped marks.
Remedy: Add two or more active fiducial mark sequences to the program.
------------------------------
Code: 230600A4
Display: Optimization cannot be performed because no valid placement sequences exist.
Used by:
Cause: Optimization cannot be performed because all placement sequences are skipped.
Remedy: The program must contain at least one placement sequence that is not to be skipped.
------------------------------
Code: 2306010C
Display: Tray part(s) cannot be loaded on the XP-341E.
Used by:
Cause: Package Type(PARTS/PACKCLS-/PPCMNPT) is 0*.
Remedy: The Package Type setting in the part data is incorrect. Check and correct the setting.
------------------------------
Code: 2306010E
Display: Dual Tape Feeder(s) cannot be loaded on the XP-341E.
Used by:
Cause: Package Type(PARTS/PACKCLS-/PPCMNPT) is 8*.
Remedy: The Package Type setting in the part data is incorrect. Check and correct the setting.
------------------------------
Code: 23078003
Display: Unregistered Tape Width.A feeder cannot be selected.
Used by:
Cause: <XP*42>Cannot optimize because feeder width is unknown.A registered Tape Width must be used
so that a feeder can be selected.
Remedy: <XP142>If Packaging Type is not "2:32mm Adhesive",set the tape width to "8","12","16","24",or
"32".
<XP242>If Packaging Type is not "0:Tray","2:32mm Adhesive","4:Stick Feeder"or "9:Grooved Stick
Feeder",set The Tape Width to "8","12","16","24","32","44","56","72",or "88".
------------------------------
Code: 23078005
Display: The stage-slot number is not defined.
Used by:
Cause: XP*42>No setting data exists for the stage-slot number specified in the sequence data.
Remedy: <XP*42>Either specify settings for the stage-slot number in the feeder setup data,or specify a
stage-slot number for which setting data already exists.
------------------------------
Code: 23078006
Display: The part data is not found.
Used by:
Cause: <XP*42>Data corresponding to the part number does not exist.
Remedy: <XP*42>Create the specified part number data,or specify an existing part number.
------------------------------
Code: 2307800E
Display: Feeders cannot be arranged.
第 2170 页
Used by:
Cause: <XP*42>Feeder optimization/Feeder configuration was performed selecting "Configure feeders
automatically"but feeders cannot be arranged.
Remedy: <XP*42>Reduce the number of part types and feeders being used or,for the XP-242 only,change
the "Feeder types used"setting in the "Feeder optimization"screen and then press [Execute].
------------------------------
Code: 2307800F
Display: Trays cannot be arranged.
Used by:
Cause: <XP*42>Feeder optimization/Feeder configuration was performed using the "Configure feeders
automatically"setting but trays cannot be arranged.
Remedy: <XP*42>Reduce the number of part types or trays being used.
------------------------------
Code: 23078011
Display: Optimization was performed using the [Fix feeder configuration]setting but trays could not be
arranged.
Used by:
Cause: <XP*42>Feeder optimization/Feeder configuration was performed using the "Fix feeder
configuration (Do not change feeder positions)"setting but trays could not be arranged.
Remedy: <XP*42>Check the feeder set up on the machine or optimize by selecting "Configure Feeders
Automatically"under "Feeder Configuration"in the "Feeder Optimization"screen.
------------------------------
Code: 23078018
Display: Tray size is too large to be loaded.
Used by:
Cause: <XP*42>The Tray Length or Width value in the Part Type data exceeds the maximum.(Tray
Length maximum:330mm;Tray Width maximum:276mm)
Remedy: <XP*42>Confirm that the Tray Length and Width values in the Part Type data do not exceed
330mm and 276mm.Trays larger than this cannot be loaded.
------------------------------
Code: 2307803B
Display: Stage number is not defined.
Used by:
Cause: <XP*42>Stage number is not defined.
Remedy: <XP*42>Input the Stage number.
------------------------------
Code: 23078042
Display: The necessary nozzles could not be allocated.
Used by:
Cause: <XP*42>Nozzle optimization/Nozzle configuration was optimized using the "Configure nozzles
automatically"setting but the necessary nozzles could not be allocated.
Remedy: <XP*42>Check the Nozzle Name,Minimum Nozzle Diameter and Maximum Nozzle Diameter
values in the Part Type data or reduce the number of parts types and feeders being used.
------------------------------
Code: 23078044
Display: No matching nozzle.
Used by:
Cause: <XP*42>The nozzle selected under Nozzle Name in the Part Type data is not on the machine.If a
Nozzle Name has not been set,there is no nozzle available to handle the range between the Minimum and
Maximum Nozzle Diameter values set.
Remedy: <XP*42>If optimization was performed with "Use machine nozzle configuration"selected under
第 2171 页