Remedy: Set the flux ejection quantity in the "Flux Cylinge Size" parameter in the Proper data. ------------------------------ Code: 1207E?37 Display: "SCU?(ICM,PMC?) Error Code:********" (QP2) "…

100%1 / 5282
Remedy: Check whether the RS cable to the MTU6 is disconnected.
------------------------------
Code: 1207E?31
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"RS Port Not Set / Flux" (QP2)
Used by: QP242
Cause: The flux application pump cannot be started because the RS port has not been set.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?32
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"RS Cable Not Connected/Flux" (QP2)
Used by: QP242
Cause: The flux application pump cannot be started because the RS cable is not connected.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?33
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Inexcutable (FZ not up-end)" (QP2)
Used by: QP242
Cause: The command cannot be executed because the flux application axis (FZ-axis) is not at the upper
limit.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use an I/O command or other method to raise the flux head.
------------------------------
Code: 1207E?34
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Pstn'g time-out (FX/TY/TZ)" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Positioning timeout (FX-axis, TY-axis, or TZ-axis).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether something is interfering with the above-named axes, or whether the axis action
has become extremely heavy. Check the robust controller for problems.
------------------------------
Code: 1207E?35
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"FZ-axis operation time-out" (QP2)
Used by: QP242
Cause: Timeout during FZ-axis operation.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether something is interfering with the FZ-axis. Make sure that the upper and lower
limit sensors are functioning normally.
------------------------------
Code: 1207E?36
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Syringe size parameter 0" (QP2)
Used by: QP242
Cause: The parameter that specifies the flux syringe size is set to 0.
(value replacing "?" is module number; error code appears in place of asterisks)
第 823 页
Remedy: Set the flux ejection quantity in the "Flux Cylinge Size" parameter in the Proper data.
------------------------------
Code: 1207E?37
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"SCU warning" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: SCU warning report.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?38
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PPC communication timeout" (QP2)
Used by: QP242
Cause: A timeout has occurred during communication with the PPC.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether the cable to the PPC is connected. Check the PPC for problems.
------------------------------
Code: 1207E?39
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Data overflow at PPC" (QP2)
Used by: QP242
Cause: PPC data overflow.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Turn the power off and on once, then perform measurements again. Make sure the cable
between the PPC and the load cell table is not broken.
------------------------------
Code: 1207E?3A
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PPC measurement unstable" (QP2)
Used by: QP242
Cause: PPC measurement values are not stable.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Turn the power off and on once, then perform measurements again. If this error occurs
frequently, the PPC must be replaced.
------------------------------
Code: 1207E?3B
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PPC Holdmode not set" (QP2)
Used by: QP242
Cause: The PPC hold mode has not been set.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Change the PPC hold mode setting to 3.
------------------------------
Code: 1207E?3C
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PPC Zero-tracking mode..." (QP2)
Used by: QP242
Cause: The PPC is operating in zero-tracking mode.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Turn the PPC zero-tracking function off.
第 824 页
------------------------------
Code: 1207E?3D
Display: "ICM (PMC?, SCU?) Error Code:********" (QP2)
"Instruction to LLL failed" (QP2)
Used by: QP242
Cause: Instruction to LLL failed. ? is the module number. "****" is the error code.
Remedy: Change the LLL board.
------------------------------
Code: 1207E?3E
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray not at retract pos." (QP2)
Used by: QP242
Cause: The TZ-axis has attempted to move but the prerequisite conditions are not being satisfied.
SCU I/O: X03D or X03E is ON, X017 is ON
MTU7: When X03D is ON, X01D is ON
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether or not the shuttle's extended position or the retract position sensor is ON. Check
that the tray storage confirmation sensor (tray's expulsion sensor) is not being blocked. If the shuttle is at
the extended position on a MTU-7, check that the TZ-axis interlock sensor is not being blocked.
------------------------------
Code: 1207E?3F
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"TZ axis not at org. pos." (QP2)
Used by: QP242
Cause: The TY-axis has attempted to move but the prerequisite conditions are not being satisfied.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check that the TY-axis movement sensor is not being blocked.
(SCU I/O: X03F TY MOVE OK POS... ON)
------------------------------
Code: 1207E?40
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Empty tray container full" (QP2)
Used by: QP242
Cause: Either the MTU-7's empty tray container is full or the tray eject sensor is being blocked.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Remove the trays from the empty tray container or remove what is blocking the tray eject sensor.
------------------------------
Code: 1207E?41
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray D No. unknown" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Currently not supported. If this error occurs, please contact Fuji.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy:
------------------------------
Code: 1207E?42
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray collect not possible" (QP2)
Used by: QP242
Cause: The tray cannot be returned to the MTU-6 magazine because the tray's device number is
unknown.