FUJI错误代码查询.pdf - 第154页

------------------------------ Code: 11022608 Display: Used by: IP1,IP2 Cause: Reducing_time in Proper data is out of range. Remedy: The range for Proper data's Reducing time is from 100 msec to 6000 msec. Check the…

100%1 / 5282
2. Check that the machines registered in the MCS line descriptor are correct.
3. Check that the channel to which the data line cable is connected is correct.
4. If the machine is an IP-1 using MCS/1, input a number other than 0 into Proper data's "Identity" item.
------------------------------
Code: 11022601
Display: 11022601
Used by: IP2
Cause: The Proper data item Nozzle size LL is set to 0 (FIP2).The nozzle size item "Nozzle size LL" in
Proper data is 0 (IP2).
Remedy: Input the correct nozzle size and then retransmit the Proper data to the machine.
------------------------------
Code: 11022602
Display: 11022602
Used by: IP2
Cause: The Proper data item Nozzle size L is set to 0 (FIP2).The nozzle size item "Nozzle size L" in Proper
data is 0 (IP2).
Remedy: Input the correct nozzle size and then retransmit the Proper data to the machine.
------------------------------
Code: 11022603
Display: 11022603
Used by: IP2
Cause: The Proper data item Nozzle size M is set to 0 (FIP2).The nozzle size item "Nozzle size M" in Proper
data is 0 (IP2).
Remedy: Input the correct nozzle size and then retransmit the Proper data to the machine.
------------------------------
Code: 11022604
Display: 11022604
Used by: IP2
Cause: The Proper data item Nozzle size S is set to 0 (FIP2).The nozzle size item "Nozzle size S" in Proper
data is 0 (IP2).
Remedy: Input the correct nozzle size and then retransmit the Proper data to the machine.
------------------------------
Code: 11022605
Display:
Used by: IP2
Cause: The Proper data item ccd level is set to 0 (IP2).
Remedy: Re-measure the CCD level and re-transmit Proper data.
------------------------------
Code: 11022606
Display:
Used by: IP1,IP2
Cause: The Proper data item max.speed_? is out of range (IP1).
Remedy: Check the Proper data item max.speed_?. The acceptable range is from 0% to 100%. Re-
transmit after changing Proper data.
------------------------------
Code: 11022607
Display:
Used by: IP1,IP2
Cause: The Proper data item Middle_? is out of range (IP1).
Remedy: Check the Proper data item Middle_?. The acceptable range is from 5 pulses to 500 pulses. Re-
transmit after changing Proper data.
第 153 页
------------------------------
Code: 11022608
Display:
Used by: IP1,IP2
Cause: Reducing_time in Proper data is out of range.
Remedy: The range for Proper data's Reducing time is from 100 msec to 6000 msec. Check the entry and
retransmit Proper data.
------------------------------
Code: 11022609
Display:
Used by: IP2
Cause: X0 in Proper data (IP2) is 0 (zero).
Remedy: Input a correct Proper data value at X0 and retransmit Proper data.
------------------------------
Code: 1102260A
Display:
Used by: IP2
Cause: Y0 in Proper data (IP2) is 0 (zero).
Remedy: Input a correct Proper data value at Y0 and retransmit Proper data.
------------------------------
Code: 1102260B
Display:
Used by: IP2
Cause: Choose Z0, 1 and 2. This is for IP2 machines with a Z axis.
Remedy: Enter the correct values and re-transmit Proper data.
------------------------------
Code: 1102260C
Display:
Used by: IP2
Cause: X feeder origin 1,4 is set at 0 (IP2).
Remedy: Enter the correct value and re-transmit the Proper data.
------------------------------
Code: 1102260D
Display:
Used by: IP2
Cause: XC 1, YC 1 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102260E
Display:
Used by: IP2
Cause: XC 2, YC 2 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 1102260F
Display:
Used by: IP2
Cause: XC 3, YC 3 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022610
第 154 页
Display:
Used by: IP2
Cause: XC 4, YC 4 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022611
Display:
Used by: IP2
Cause: Camera X1, Y1 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022612
Display:
Used by: IP2
Cause: Camera X2, Y2 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022613
Display:
Used by: IP2
Cause: Camera X3, Y3 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022614
Display:
Used by: IP2
Cause: Camera X4, Y4 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022615
Display:
Used by: IP2
Cause: X dot 1, Y dot 1 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022616
Display:
Used by: IP2
Cause: X dot 2, Y dot 2 is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022617
Display:
Used by: IP2
Cause: X dot H, Y dot H is set at 0 (IP2).
Remedy: Enter the correct Proper value and re-transmit the Proper data.
------------------------------
Code: 11022618
Display:
Used by: IP2
Cause: X act origin is set at 0 (IP2).
第 155 页