FUJI错误代码查询.pdf - 第1167页
Remedy: Reexecute the command, or cut and resupply power to the HT. ------------------------------ Code: 1801012E Display: HT command trans. error HT error: 1801012E Used by: QP132 Cause: Command could not be transmitted…
Code: 18010108
Display: None
Used by: QP132
Cause: An HT association request was issued during automatic operation, etc., when an association
status is prohibited.
Remedy: Execute the HT association request when automatic operation is not in progress.
------------------------------
Code: 18010109
Display: None
Used by: QP132
Cause: An association failure occurred.
Remedy: Refer to the guidance message displayed on the machine.
------------------------------
Code: 1801011?
Display: HT err: ****
HT command handshake error
Used by: QP132
Cause: A verify report was received when a verify report (including splicing check) waiting status was not
in effect.
"****" is the command name.
"?" is the command number.
Remedy: Execute a verify request.
------------------------------
Code: 1801012A
Display: Executing HT command
HT error: 1801012A
Used by: QP132
Cause: The specified command cannot be executed.
Remedy: Check that verification processing (or splicing) are not being performed. Alternatively, cut and
resupply power to the HT.
------------------------------
Code: 1801012B
Display: HT command error
HT error: 1801012B
Used by: QP132
Cause: A verification or splicing request was issued from the machine, but the appropriate feeder cannot
be located.
Remedy: Check the feeders, and perform verification again.
------------------------------
Code: 1801012C
Display: HT command type error
HT error: 1801012C
Used by: QP132
Cause: The command issued from the HT is not supported.
Remedy: Check the command or cut and resupply power to the HT.
------------------------------
Code: 1801012D
Display: HT command time out
HT error: 1801012D
Used by: QP132
Cause: The command issued to the HT timed out.
第 1166 页
Remedy: Reexecute the command, or cut and resupply power to the HT.
------------------------------
Code: 1801012E
Display: HT command trans. error
HT error: 1801012E
Used by: QP132
Cause: Command could not be transmitted to the HT.
Remedy: Cut and resupply power to the HT.
------------------------------
Code: 18010131
Display: None
Used by: QP132
Cause: Current status not suitable for data change.
Remedy: Ensure that parts supply changes have been enabled at Proper data item "88. Parts Supply".
Check the command.
------------------------------
Code: 18020004
Display: Fujitrax-Verifier DB error.
Used by:
Cause: An error has occurred at the Fujitrax-Verifier database.
Remedy: Perform maintenance on the Fujitrax-Verifier database.
------------------------------
Code: 18020007
Display: Fujitrax-Verifier no ID information.
Used by:
Cause: There is no feeder or part information.
The set feeder FIDL or the part's DID is not registered in the Fujitrax-Verifier database.
The parameter indicates the target slot number.
Remedy: Check that the feeder FIDL and the part DID for the slot indicating "No ID information" or
"Unchecked" (during changeover) are registered in the Fujitrax-Verifier database.
------------------------------
Code: 18020008
Display: Fujitrax-Verifier device comment mismatch.
Used by:
Cause: The part device comment does not match the one registered in Fujitrax-Verifier.
The parameter indicates the target slot number.
Remedy: Check the DID device comment of the part set at the target slot, and check the device comment
registered in Fujitrax-Verifier.
------------------------------
Code: 18020009
Display: Fujitrax-Verifier parts out.
Used by:
Cause: Fujitrax-Verifier has reported that there are insufficient parts to continue production (parts out
limit).
The parameter indicates the target slot number.
Remedy: Check the target slot and resupply parts as necessary.
If there are still parts available, check if the remaining parts count at Fujitrax-Verifier is down to 0.
------------------------------
Code: 18020015
Display: Fujitrax-Verifier parts limit.
Used by:
第 1167 页
Cause: Fujitrax-Verifier has reported that production cannot continue because the low quantity limit has
been reached.
The parameter indicates the target slot number.
Remedy: Resupply parts to the feeder that has reached the low quantity limit (indicated at the device
check screen).
------------------------------
Code: 18020016
Display: Fujitrax-Verifier splicing warning.
Used by:
Cause: Fujitrax-Verifier has reported that production cannot continue because of a splicing warning.
The parameter indicates the target slot number.
Remedy: Splice new parts to the feeder at the target slot.
------------------------------
Code: 18020024
Display: Changeover database error.
Used by:
Cause: An error has occurred at the Kitting Station changeover database.
Remedy: Perform maintenance on the Kitting Station changeover database.
------------------------------
Code: 18020025
Display: Changeover not initiated.
Used by:
Cause: Changeover preparations have not been carried out at the Kitting Station for the supply unit
specified at the Handy Terminal.
The parameter indicates the target unit number.
Remedy: Perform changeover preparations again at the Kitting Station, or carry out a device check again
at the machine.
------------------------------
Code: 18020026
Display: Changeover supply unit mismatch.
Used by:
Cause: The supply unit for which changeover preparations were carried out at the Kitting Station does
not match the unit specified at the Handy Terminal.
The parameter indicates the target unit number.
Remedy: Move the supply unit to the specified stage.
To continue operation, perform a device check again at the machine.
------------------------------
Code: 18020027
Display: Changeover incomplete.
Used by:
Cause: Changeover preparations for the supply unit specified at the Handy Terminal are not complete.
Remedy: Complete the device checks for any feeders for which verification is not completed at the device
check screen.
------------------------------
Code: 18020028
Display: Fujitrax-Verifier communications timeout.
Used by:
Cause: Communications with the KIT Server have timed out.
An error has occurred at the KIT Server, or communication between the KIT Server and the machine
has been cut.
Remedy: Check the KIT Server.
第 1168 页