FUJI错误代码查询.pdf - 第239页
Code: 11100409 Display: Machine status memory file error Used by: NP2,QP3 Cause: data in the memory file was cleared at the previous power off. Remedy: Specify the following: production program, production mode, operatio…
Error handling mode (Recovery)
Recovery timing (Recovery)
Block skip mark reading mode (Operation)
Nozzle station (Nozzle Settings)
Nozzle alllocation (Nozzle Settings)
------------------------------
Code: 11100406
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the machine status file. All machine status settings have
been cleared.
Remedy: The following items must be specified again.
Program
Production mode (Production)
Operation mode (Operation
Error handling mode (Recovery)
Recovery timing (Recovery)
Block skip mark reading mode (Operation)
Nozzle station (Nozzle Settings)
Nozzle alllocation (Nozzle Settings)
------------------------------
Code: 11100407
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are outside the prescribed range. All machine status
settings have been cleared.
Remedy: The following items must be specified again.
Program
Production mode (Production)
Operation mode (Operation
Error handling mode (Recovery)
Recovery timing (Recovery)
Block skip mark reading mode (Operation)
Nozzle station (Nozzle Settings)
Nozzle alllocation (Nozzle Settings)
------------------------------
Code: 11100408
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the machine status file. All system
settings have been cleared.
Remedy: The following items must be specified again.
Program
Production mode (Production)
Operation mode (Operation
Error handling mode (Recovery)
Recovery timing (Recovery)
Block skip mark reading mode (Operation)
Nozzle station (Nozzle Settings)
Nozzle alllocation (Nozzle Settings)
------------------------------
第 238 页
Code: 11100409
Display: Machine status memory file error
Used by: NP2,QP3
Cause: data in the memory file was cleared at the previous power off.
Remedy: Specify the following: production program, production mode, operation mode, recovery mode,
recovery operation mode, BS mark reading mode, nest name, nozzle memory.
------------------------------
Code: 11100501
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open the nozzle memory file.
Remedy: Load the settings using the [Update] command.
------------------------------
Code: 11100502
Display: File save error!
Used by: NP2,QP3
Cause: Failed to write nozzle memory file to the hard disk.
Remedy: Check the condition of the hard disk.
------------------------------
Code: 11100503
Display: File creation error!
Used by: NP2,QP3
Cause: Failed to create new nozzle memory file.
Remedy: Check the condition of the hard disk.
------------------------------
Code: 11100504
Display: Revision file error!
Used by: NP2,QP3
Cause: The revision of the nozzle memory file is too old. All data items have been reset to their default
values.
Remedy: Load the settings using the [Update] command.
------------------------------
Code: 11100505
Display: Revision file error!
Used by: NP2,QP3
Cause: The revision file for the nozzle memory file is too new. All nozzle settings have been cleared.
Remedy: Load the settings using the [Update] command.
------------------------------
Code: 11100506
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the nozzle memory file. All nozzle settings have been
cleared.
Remedy: Load the settings using the [Update] command.
------------------------------
Code: 11100507
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are outside the prescribed range. All nozzle settings
have been cleared.
Remedy: Load the settings using the [Update] command.
第 239 页
------------------------------
Code: 11100508
Display: Nozzle memory file error
Used by: NP2,QP3
Cause: A nozzle memory file error occurred. All nozzle memory data has been cleared.
Remedy: Use the nozzle memory change command to re-register the nozzles.
------------------------------
Code: 11100601
Display: File-open error!
Used by: NP2,QP3
Cause: Failed to open nozzle specifications file. All nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100602
Display: File-type error!
Used by: NP2,QP3
Cause: The selected file is not a nozzle specifications file.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100603
Display: CCIMF file format error!
Used by: NP2,QP3
Cause: A CCIMF file format error occurred for the nozzle specifications file. All nozzle settings have been
cleared.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100604
Display: Out-of-range error!
Used by: NP2,QP3
Cause: The nozzle data items displayed in the parameter section are outside the prescribed range. All
nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100605
Display: Insufficient data!
Used by: NP2,QP3
Cause: The items displayed in the parameter section are missing from the nozzle specifications file. All
nozzle settings have been cleared.
Remedy: Download an uncorrupted nozzle specifications file, reboot the machine and load the settings
using the [Update] command.
------------------------------
Code: 11100606
Display: Insufficient data!
Used by: NP2,QP3
Cause: Nozzle data for this machine are not included in the nozzle data file. All nozzle settings have been
cleared.
Remedy: Download compatible nozzle specification files, reboot the machine and load the settings using
第 240 页