FUJI错误代码查询.pdf - 第1222页

Display: No VP Board Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203 Cause: This error occurs when checking the type of vision processing board. Remedy: Ensure that the vison processing board is installed in the VME r…

100%1 / 5282
Used by:
Cause: Failed to read the nozzle offset value.
Remedy: This error occurs if an attempt is made to read the nozzle offset value before the "nozzle object"
has been generated. This is not a common error. There could be a visionsystem abnormality. Restart the
system. Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFF5013
Display: 1CFF5013
Used by:
Cause: Failed to read the nozzle center value.
Remedy: This error occurs if an attempt is made to read the nozzle center value before the "nozzle object"
has been generated. This is not a common error. There could be a visionsystem abnormality. Restart the
system. Obtain the trace data and contact Fuji if this error occurs multiple times.
------------------------------
Code: 1CFFF001
Display: Communication Error with Vision Processor
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: Communication is not possible due to a vision processing error.
Remedy: Turn off the machine.If this error occurs often contact Fuji.
------------------------------
Code: 1CFFF003
Display: Application Error
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: Error in the parameters determining the vision processing method.
Remedy: Turn off the machine.If this occurs often contact Fuji.
------------------------------
Code: 1CFFF004
Display: VP Software Version Error
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: The vision processing function was not supported in the vision processing software.
Remedy: Use the up-grade version software supporting the necessary functions.
------------------------------
Code: 1CFFF006
Display: Application error
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: This error occurs when the specified registered image does not exist.
Remedy: Turn off the machine. Reset-start the machine.If this occurs often contact Fuji.
------------------------------
Code: 1CFFF007
Display: Application error
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: The specific data for the registered image is wrong.
Remedy: Turn off the machine. Restart the machine. If this occurs often contact Fuji.
------------------------------
Code: 1CFFF008
Display: Communication Error with Multiplexer.
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: This error occurs when communication with the multiplexer becomes impossible.
Remedy: Turn off the machine and ensure that the cables are connected to the multiplexer.
------------------------------
Code: 1CFFF009
第 1221 页
Display: No VP Board
Used by: GP2,GP3,GP551,GP6,QP242,QP201,QP202,QP203
Cause: This error occurs when checking the type of vision processing board.
Remedy: Ensure that the vison processing board is installed in the VME rack. If it exists, then check the
setting of the dip switches on the front of the vision processing board.
------------------------------
Code: 1D000001
Display:
Used by:
Cause: There is a vision processing pitch error (When MCS displayed the new version and the machine is
using the old version).
Remedy: Check the part pitch or Part data.
------------------------------
Code: 1D000002
Display:
Used by:
Cause: There is a vision processing pitch error (When MCS displayed the new version and the machine is
using the old version).
Remedy: Check the orientation of the parts on the feeder. Check Part data.
------------------------------
Code: 1D005001
Display: 影像处理系统出错
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 影像处理系统出错
Remedy: 是内部错误,一般不发生。如果发生时,请获取跟踪数据并与生产程序或元件数据一起送至弊社。
------------------------------
Code: 1D005002
Display: 影像处理系统出错
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 影像处理系统出错
Remedy: 是内部错误,一般不发生。如果发生时,请获取跟踪数据并与生产程序或元件数据一起送至弊社。
------------------------------
Code: 1D005003
Display: 影像处理系统出错
Used by: XP241,XP341,XP242
Cause: 影像处理系统出错
Remedy: 在元件数据的第1要素中记载的引脚数太少时,不能进行粗定位。请修正元件数据。
------------------------------
Code: 1D005004
Display: 图形匹配出错
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 由于某种原因,图形匹配失败。
Remedy: 请更换发生错误的元件或确认元件数据以及模板是否正确。
如果元件数据以及模板正确时,请调查吸取状态是否不良、影像的明亮度是否有问题、焦距是否对准以及是否摄
有污垢。
<XP24*><XP341>
多画面处理时,请确认以分割画面摄入的影像的合成是否正常地进行。
合成没有正常地进行时,请确认元件的高度和元件数据的 Part Height 是否正确、吸嘴置放地测定是否正常地
进行。
------------------------------
Code: 1D005005
第 1222 页
Display: X方向尺寸出错
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 图形匹配成功了,但是X边的外形尺寸超过公差值(元件数据的Body Length Tolerance)。
Remedy: 请确认是否在元件处于竖立的状态下吸取。
请确认元件数据的 Body Length Tolerance 的值是否极端地小。
请更换发生错误的元件或确认元件数据是否正确。
元件数据正确时,请调查吸取状态是否不良、影像的明亮度是否有问题、焦距是否对准以及是否摄有污垢。
<XP24*><XP341>
多画面处理时,请确认以分割画面摄入的影像的合成是否正常地进行。
合成没有正常地进行时,请确认元件的高度和元件数据的 Part Height 是否正确、吸嘴置放地测定是否正常地
进行。
<XP*42>
用VisionType10时,当元件侧面有圆角时,有时元件尺寸会拍摄得比实际尺寸小而发生X方向的元件尺寸错误
错误发生后,按下在[自动]画面右上方的[错误信息]按键后,在显示[错误信息]画面上的「Body Size X Result」
中显示出用影像处理所测定的元件尺寸X,请将其值设定为元件数据的「BodyLength」。
------------------------------
Code: 1D005006
Display: Y方向尺寸出错
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 图形匹配成功了,但是Y边的外形尺寸超过公差值(元件数据的Body Width Tolerance)。
Remedy: 请确认是否在元件处于竖立的状态下吸取。
请确认元件数据的 Body Width Tolerance 的值是否极端地小。
请更换发生错误的元件或确认元件数据是否正确。
元件数据正确时,请调查吸取状态是否不良、影像的明亮度是否有问题、焦距是否对准以及是否摄有污垢。
<XP24*><XP341>
多画面处理时,请确认以分割画面摄入的影像的合成是否正常地进行。
合成没有正常地进行时,请确认元件的高度和元件数据的Part Height是否正确、吸嘴置放地测定是否正常地进
行。
<XP*42>
用VisionType10时,当元件侧面有圆角时,有时元件尺寸会拍摄得比实际尺寸小而发生Y方向的元件尺寸错误
错误发生后,按下在[自动]画面右上方的[错误信息]按键后,在显示[错误信息]画面上的「Body Size Y Result」
中显示出用影像处理所测定的元件尺寸Y,请将其值设定为元件数据的「BodyWidth」。
------------------------------
Code: 1D005007
Display: 检查查找线出错
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 因检查查找线产生的检查错误。
Remedy: 请更换发生错误的元件或确认元件数据是否正确。
元件数据正确时,请调查吸取状态是否不好、影像的明亮度是否有问题、焦距是否对准以及是否摄有污垢。
<XP24*><XP341>
多画面处理时,请确认以分割画面摄入的影像的合成是否正常地进行。
合成没有正常地进行时,请确认元件的高度和元件数据的 Part Height 是否正确、吸嘴置放地测定是否正常地
进行。
------------------------------
Code: 1D005008
Display: 影像处理系统出错
Used by: XP241,XP341,XP242
Cause: 影像处理系统出错
Remedy: 是内部错误,一般不发生。如果发生时,请获取跟踪数据并与生产程序或元件数据一起送至弊社。
第 1223 页