FUJI错误代码查询.pdf - 第1883页
Cause: The set file data field does not match the format of the data field. Remedy: Change either the file or the format. Select F3 to check the data. ------------------------------ Code: 21005333 Display: Selected file …
and Status data.
Remedy: Except on the above mentioned data, data check cannot be performed. Save the changes and
shut down the editor.
------------------------------
Code: 21005310
Display: File already exists
Used by:
Cause: The file specified already exists.
Remedy: Choose whether or not to overwrite the file.
------------------------------
Code: 21005311
Display: Filename not specified
Used by:
Cause: The filename was not specified in the command.
Remedy: Specify the filename.
------------------------------
Code: 21005320
Display: Start_line or End_line not selected
Used by:
Cause: The line was not specified at "blk wrte."
Remedy: After entering the correct starting and finishing line, press the F6 [execute] key.
------------------------------
Code: 21005321
Display: Start_line or End_line record count over
Used by:
Cause: The specified line specified in the blk wrte command does not exist.
Remedy: After checking that the correct starting and finishing lines are specified, re-execute the function.
------------------------------
Code: 21005322
Display: Not "Block" or "Sequence" data
Used by:
Cause: The digitize command was executed for data other than block or sequence data.
Remedy: The digitize command can only be executed on the above mentioned data.
------------------------------
Code: 21005330
Display: Record Field Over
Used by:
Cause: When a read command was executed, the number of data items read exceeded the number able
to be handled by the software.
Remedy: Reduce the number of data items being read.
------------------------------
Code: 21005331
Display: Selected file is not a block data file.
Used by:
Cause: The selected file is not a block data file.
Remedy: Check the block data display contents. Check that "BLOCK" is displayed under the "TYPE"
heading in the ls directory display.
------------------------------
Code: 21005332
Display: Block read data does not match data block format.
Used by:
第 1882 页
Cause: The set file data field does not match the format of the data field.
Remedy: Change either the file or the format. Select F3 to check the data.
------------------------------
Code: 21005333
Display: Selected file not found
Used by:
Cause: The filename does not exist.
Remedy: Select F1 for a directory of files.
------------------------------
Code: 21005350
Display: Generic device editor open error.
Used by:
Cause: The generic device editor will not operate. The generic device editor module does not exist.
Remedy: Install the generic device editor.
------------------------------
Code: 21005390
Display: Failed to create geniric device.
Used by:
Cause: A generic device file could not be created.
Remedy: Check Part data.
------------------------------
Code: 21005400
Display: Index not found
Used by:
Cause: The index was not found when inputting items.
Remedy: Input the index again, and re-execute.
------------------------------
Code: 21005401
Display: Editor descriptor index not found.
Used by:
Cause: The editor descriptor index was not found.
Remedy: Check the index guide and re-execute.
------------------------------
Code: 21005402
Display: This file is not a program file.
Used by:
Cause: This file is not a production program or source program.
Remedy: Select C with the command key. Only these production or source programs can be used.
------------------------------
Code: 21005403
Display: Select index not used not execute line command.
Used by:
Cause: An index error occurred.
Remedy: Re-install the editor software.
------------------------------
Code: 21005404
Display: Srch data not found
Used by:
Cause: The specified data was not found.
Remedy: Check the data.
------------------------------
第 1883 页
Code: 21005501
Display: Specified device number not found in device data.
Used by:
Cause: The device number does not exist.
Remedy: Change the device data and try again.
------------------------------
Code: 21005502
Display: Specified device number not found in sequence data.
Used by:
Cause: This is a warning.
Remedy: The specified device number was not found in sequence data. The sequence data accompanying
the specified device number does not exist.
------------------------------
Code: 21005503
Display: Working mode not 'D'
Used by:
Cause: The input device number was wrong.
Remedy: The input device number must have an accompanying sequence number.
------------------------------
Code: 21005507
Display: Change command device number not select
Used by:
Cause: Either the device number was not changed or not input.
Remedy: After inputting the data, select F6 [execute].
------------------------------
Code: 21005555
Display: This item is automatically set; no setting required.
Used by:
Cause: This item is automatically set. No setting is required.
Remedy: This is just a warning message. It is not an error.
------------------------------
Code: 21005600
Display: Data entry error. Please check (File descriptor MIN & MAX)
Used by:
Cause: When inputting a block of data, some input was out of range.
Remedy: Adjust the input data and re-input the data.
------------------------------
Code: 21005601
Display: Search data not found.
Used by:
Cause: The data does not exist.
Remedy: Edit the data and re-execute.
------------------------------
Code: 21005602
Display: Data type parameter not specified in srch/rpl command.
Used by:
Cause: The parameter when the direct command was input is wrong.
Remedy: Check the input parameter.
------------------------------
Code: 21005603
Display: Data type match not found.
第 1884 页