FUJI错误代码查询.pdf - 第2159页

Remedy: There is a problem with a sequence field in the program file. Check that the file contents are correct. When the stage number value is 1, the slot number input range is 1 to 100. ------------------------------ Co…

100%1 / 5282
Used by:
Cause: When either or both Stage and Slot number is zero, and the device number is also zero,
placement cannot be performed as the slot cannot be determined.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 100, and when stage 2 is specified, the slot
number input range is 1 to 400.
------------------------------
Code: 23050037
Display: The program file feeder setup stage and slot No. are set to zero.
Used by:
Cause: When either or both Stage and Slot number is zero, and the device number is also zero, feeders
cannot be allotted as the slot cannot be determined.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct.
The device number input range is 1 to 500.
When specifying a stage - slot arrangement, when stage 1 is specified, the slot number input range is 1 to
100, and when stage 2 is specified, the slot number input range is 1 to 400.
------------------------------
Code: 23050039
Display: No compatible nozzle diameter exists for this part.
Used by:
Cause: When creating the nozzle arrangement automatically, no Nozzle Diameter could be found within
the range defined by Minimum Nozzle Diameter and Maximum Nozzle Diameter in the part data.
Remedy: Try optimizing the program using [Automatic Nozzle Arrangement]. If still unsuccessful, check
the Minimum Nozzle Diameter (PARTS/ENVDT/XP241ENVDT-/PENMI) and Maximum Nozzle Diameter
(PARTS/ENVDT/XP241ENVDT-/PENMA) settings in the part data.
------------------------------
Code: 2305003A
Display: The stage/slot numbers for the following placement sequence in the program file are zero.
Used by:
Cause: Because either the stage or slot number is zero, the device number is referenced for calculation,
however the specified device number is outside the input range of 1 to 500.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct.
The device number input range is 1 to 500.
When specifying a stage - slot arrangement, when stage 1 is specified, the slot number input range is 1 to
100, and when stage 2 is specified, the slot number input range is 1 to 400.
------------------------------
Code: 2305003B
Display: The stage number value in the following sequence in the program file is out of range.
Used by:
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct.
The stage number input range is 1 to 2.
------------------------------
Code: 2305003C
Display: The slot number value in the following sequence in the program file is out of range.
Used by:
Cause: The stage number value is 1, but the slot number value is out of range.
第 2158 页
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct.
When the stage number value is 1, the slot number input range is 1 to 100.
------------------------------
Code: 2305003D
Display: The slot number value in the following sequence in the program file is out of range.
Used by:
Cause: The stage number value is 2, but the slot number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct.
When the stage number value is 2, the slot number input range is 1 to 400.
------------------------------
Code: 2305003E
Display: The stage/slot numbers for the following feeder setup in the program file are zero.
Used by:
Cause: Because either the stage or slot number is zero, the device number is referenced for calculation,
however the specified device number is outside the input range of 1 to 500.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct.
The device number input range is 1 to 500.
When specifying a stage - slot arrangement, when stage 1 is specified, the slot number input range is 1 to
100, and when stage 2 is specified, the slot number input range is 1 to 400.
------------------------------
Code: 2305003F
Display: The stage number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct.
The stage number input range is 1 to 2.
------------------------------
Code: 23050040
Display: The slot number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The stage number value is 1, but the slot number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct.
When the stage number value is 1, the slot number input range is 1 to 100.
------------------------------
Code: 23050041
Display: The slot number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The stage number value is 2, but the slot number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct.
When the stage number value is 2, the slot number input range is 1 to 400.
------------------------------
Code: 23050042
Display: Even if nozzle kinds are combined so that the maximum diameter nozzles are not used, there are
too many nozzle kinds to fit in the folder.
Used by:
第 2159 页
Cause: When using automatic nozzle arrangement, the required number of nozzles exceed the number in
the nozzle folder.
Remedy: The program file is incorrect. Check the Nozzle Spec. file, or check the Minimum Nozzle
Diameter (PARTS/ENVDT/XP241ENVDT-/PENMI) and Maximum Nozzle Diameter
(PARTS/ENVDT/XP241ENVDT-/PENMA) settings in the part data.
------------------------------
Code: 23050043
Display: An inputted nozzle name does not exist in Nozzle Configuration File and the Nozzle Specification
File.
Used by:
Cause: The inputted nozzle name does not exist in the Nozzle Configuration file and Nozzle Specification
file.
Remedy: Try optimizing the program using [Automatic Nozzle Arrangement]. If still unsuccessful, check
the Nozzle Spec. file, or check the Minimum Nozzle Diameter (PARTS/ENVDT/XP241ENVDT-/PENMI) and
Maximum Nozzle Diameter (PARTS/ENVDT/XP241ENVDT-/PENMA) settings in the part data.
------------------------------
Code: 23050044
Display: There is no nozzle suitable for the part.
Used by:
Cause: There is no suitable nozzle available in the nozzle folder for the part.
Remedy: Open the Optimize Condition settings screen. Under the heading [Nozzle Arrangement], select
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle arrangement] method. If using [Automatic Nozzle
Arrangement], check the Nozzle Spec. file, or check the Minimum Nozzle Diameter
(PARTS/ENVDT/XP241ENVDT-/PENMI) and Maximum Nozzle Diameter (PARTS/ENVDT/XP241ENVDT-
/PENMA) settings in the part data.
------------------------------
Code: 23050045
Display: There is no nozzle of the name specified for the parts.
Used by:
Cause: In the nozzle folder, there is no nozzle of the name specified for the parts.
Remedy: Open the Optimize Condition settings screen. Under the heading [Nozzle Arrangement], select
the method that was used for optimization, and correct the nozzle settings as necessary for the [Use
Present Nozzle Arrangement] or [Manual Nozzle arrangement] method. If using [Automatic Nozzle
Arrangement], check the Nozzle Spec. file, or check the Nozzle Name (PARTS/ENVDT/XP241ENVDT-
/PENNZN) in the part data.
------------------------------
Code: 23050047
Display: The Alt. Feeder number must be set to a different slot. Set the Alt. Feeder number to 0?
Used by:
Cause: A Alt. Feeder number has been set for the same slot.
Remedy: In the program file's Feeder Setup settings, and change the Alt. Feeder number
(PROGRAM/DEVICE+/GUTNSLTN) to 0 (No Alt. Feeder) or to another slot number.
------------------------------
Code: 23050048
Display: A Alt. Feeder is duplicated, or two or more first slots (reference slot) have been specified for the
same alternate feeder loop.
The Alt. Feeder settings will be deleted.
Used by:
Cause: Two or more alternate feeder loops may be overlapping.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
第 2160 页