Cause: According to the conveyor end sensor there is a part on the conveyor. Remedy: Due to a pickup mistake made by the IP machine, there is an unnecessary part on the conveyor. In this case, remove the part. ----------…

100%1 / 5282
Code: 110823D0
Display: Y-Axis Not in Retract Pos
Used by: MTU4
Cause: The Y axis speed reduction sensor was not on when the T axis attempted to move.
Remedy: Check the Y axis speed reduction sensor and the dog. Also check that a suitable value has been
entered for the MTU4 Proper data item Carrier_Position_SY.
------------------------------
Code: 11082400
Display: 11082400
Used by: MTU3,MTU5
Cause: An attempt was made to advance the Y axis to the Z axis interlock position.
Remedy: Check the Z axis interlock sensor and dog.
------------------------------
Code: 11082410
Display: 11082410
Used by: MTU3,MTU5
Cause: When the sub-nozzle placed a part on the conveyor, the nozzle's vacuum sensor judged that there
was still a part on the nozzle.
Remedy: Check the mouth of the nozzle, the air supply, the sensor etc.
------------------------------
Code: 11082420
Display: 11082420
Used by: MTU3,MTU5
Cause: A tray part picked up by the sub-nozzle was dropped before it was placed on the conveyor.
Remedy: Check the mouth of the nozzle, the air supply system etc. Also check that suitable values have
been entered in part data and for the Proper data item Tray_Pos_T.
------------------------------
Code: 11082421
Display: 11082421
Used by: MTU3,MTU5
Cause: When an attempt was made to deliver a part to the IP machine, the conveyor parts check sensor
judged that there was no part on the conveyor.
Remedy: Check whether the part fell off the conveyor during delivery.
------------------------------
Code: 11082430
Display: 11082430
Used by: MTU3,MTU5
Cause: When the X and Z axes attempted to move during automatic operation, the Y axis retract sensor
was not on.
Remedy: Check that a suitable value has been entered for the Proper data item Interlock_SY.
Furthermore, adjust the sensor and the dog.
------------------------------
Code: 11082440
Display: 11082440
Used by: MTU3,MTU5
Cause: The Z axis retract sensor was off when the sub-nozzle shaft retracted during automatic operation.
Remedy: Check that the nozzle retracts correctly. Also check that the sensor is functioning correctly.
------------------------------
Code: 11082450
Display: 11082450
Used by: MTU3,MTU5
第 222 页
Cause: According to the conveyor end sensor there is a part on the conveyor.
Remedy: Due to a pickup mistake made by the IP machine, there is an unnecessary part on the conveyor.
In this case, remove the part.
------------------------------
Code: 11082460
Display: 11082460
Used by: MTU3,MTU5
Cause: The parts supply door at the back of the MTU is open.
Remedy: Close the door. In addition, check that the door is properly positioned.
------------------------------
Code: 11082490
Display: 11082490
Used by: MTU3,MTU5
Cause: The tray set sensor is off. A tray may have stopped mid-way through being ejected.
Remedy: Check that all of the trays in the column at the nozzle position where the error occurred are
correctly positioned. In addition, check that the sensor positions match the tray positions.
------------------------------
Code: 110824A0
Display: 110824A0
Used by: MTU3,MTU5
Cause: There is an unexpected part on the sub-nozzle. The part may have been placed there by the
operator.
Remedy: Remove the part on the sub-nozzle.
------------------------------
Code: 11083200
Display: Sequence number is out of range.
Used by: MTU4
Details: The sequence number is out of the valid range.
Cause:
Remedy: Ensure that the sequence number is between 1 and 4999.
------------------------------
Code: 11083210
Display: Device number is out of range.
Used by: MTU4
Details: The device number for the tray part is out of the valid range.
Cause:
Remedy: Ensure that the first digit in the device number is 1 for a tray unit on the right side, or 3 for a
tray unit on the left side. The second digit in the device number must be between 0 to 9, and the last digit
in the device number must be between 1 to 4.
------------------------------
Code: 11083220
Display: Terminate setting out of range.
Used by: MTU4
Details: A setting for a terminate sequence is out of the valid range.
Cause:
Remedy: The setting for the terminate sequence must either be ˇˇ(for a non terminate sequence) or
ˇˇ(for a terminate sequence).
------------------------------
Code: 110832F0
Display: Sequence Data Device Number Out of Range
Used by: MTU3,MTU4,MTU5
第 223 页
Cause: When AUTO or STEP operation was entered, there was no sequence data in the program.
Remedy: Download the program again to the IP machine. If the error occurs repeatedly, contact Fuji.
------------------------------
Code: 11083300
Display: Device no. out of range
Used by: MTU4
Cause: The slot number specified for tray parts is out of range.
Remedy: Check the ranges of the three digits in the device slot number. Input 1 (Right side) or 3 (Left
side) for the first digit (eg. 1??), a value between 0-9 (Shelf no.)for the second digit (eg. ?0?), and a value
between 1-4 (Tray compartment) for the third digit (eg. ??1).
------------------------------
Code: 11083301
Display: Next device no. out of range
Used by: MTU4
Cause: The next device slot number specified for tray parts is out of range.
Remedy: Check the three digits in the next device slot number. Input 1 (Right side) or 3 (Left side) for the
first digit (eg. 1??), a value between 0-9 (Shelf no.)for the second digit (eg. ?0?), and a value between 1-4
(Tray compartment) for the third digit (eg. ??1).
------------------------------
Code: 11083302
Display: Part height out of range
Used by: MTU4
Cause: The specified part height for tray parts is out of range.
Remedy: Input a value between 0 to 35.00(mm) in the Part data item Component Height.
------------------------------
Code: 11083310
Display: Cavity pitch (X) out of range
Used by: MTU4
Cause: The specified tray cavity pitch (X) is out of range.
Remedy: Input a value between 0 to 250.00(mm) in the Part data item Component Pitch (X).
------------------------------
Code: 11083311
Display: Cavity pitch (Y) out of range
Used by: MTU4
Cause: The specified tray cavity pitch (Y) is out of range.
Remedy: Input a value between 0 to 350.00(mm) in the Part data item Component Pitch (Y).
------------------------------
Code: 11083312
Display: Cavity quantity (X) out of range
Used by: MTU4
Cause: The specified cavity quantity (X) is out of range.
Remedy: Input a value between 0 to 50(cavities) in the Part data item Cavities (X).
------------------------------
Code: 11083313
Display: Cavity quantity (Y) out of range
Used by: MTU4
Cause: The specified cavity quantity (Y) is out of range.
Remedy: Input a value between 0 to 50(cavities) in the Part data item Cavities (Y).
------------------------------
Code: 11083314
Display: Tray pickup point (X) out of range