FUJI错误代码查询.pdf - 第2133页

Display: The mark check position (area)is outside the body. Used by: Cause: The mark check position (area)is outside the body. Remedy: Enter the correct mark check position (area)coordinates. ----------------------------…

100%1 / 5282
Used by:
Cause: A part number with a Packaging Type of "Tray" is set for a Feeder stage number and slot number,
or, a part number with a Packaging Type other than "Tray" is set for a Tray stage number and slot
number.
Remedy: For Feeder stage numbers and slot numbers, specify a part number with a Packaging Type other
than "Tray". For Tray stage numbers and slot numbers, specify a part number with Packaging Type of
"Tray".
------------------------------
Code: 2300E401
Display: Fiducial Marks have not been set.
Used by:
Cause: There is no fiducial mark setting in the production program.
Remedy: Specify a fiducial mark setting at the Edit Mark screen.
------------------------------
Code: 2300E402
Display: Board skip marks have not been set.
Used by:
Cause: A board skip mark reading sequence exists, but there is no board skip mark setting.
Remedy: Specify a board skip mark setting at the Edit Mark screen.
------------------------------
Code: 2300E501
Display: The Polarity Setting item's [Not Use] setting is not supported.
Used by:
Cause: XP-series machines do not support Polarity Setting's "Not Use" setting.q宝xcept for program data
transmitted from MCS/2q搽Remedy: Set the Polarity Setting to another setting.
Remedy:
------------------------------
Code: 2300E502
Display: The Polarity Setting setting [Not Use] in the production program which was transmitted from the
MCS/2 to the XP-141E is not supported.
Used by:
Cause: MCS/2 programs used on XP-141E with the Polarity Setting set to "Not Use" cannot be used on
other machine types.
Remedy: Set the Polarity Setting to another setting.
------------------------------
Code: 2300E503
Display: The Polarity Setting setting [Not Use] in the production program which was transmitted from the
MCS/2 to the XP-241E/XP-341E is not supported.
Used by:
Cause: MCS/2 programs used on XP-241E and XP-341E with the Polarity Setting set to "Not Use" cannot
be used on other machine types.
Remedy: Set the Polarity Setting to another setting.
------------------------------
Code: 2300E540
Display: No suitable nozzle exists.
Used by:
Cause: The nozzle data contains neither the nozzle specified by the NozzleName item (in Part Type data),
or a nozzle which satisfies the NozzleSizeMin to NozzleSizeMax range setting.
Remedy: Specify the appropriate nozzle in the nozzle data.
------------------------------
Code: 2300E541
第 2132 页
Display: The mark check position (area)is outside the body.
Used by:
Cause: The mark check position (area)is outside the body.
Remedy: Enter the correct mark check position (area)coordinates.
------------------------------
Code: 2300E542
Display: Mark check area is improper.
Used by:
Cause: Mark check area is improper.
Remedy: Enter the correct mark check area coordinates.
This error occurs when the 'Upper Left X' and 'Lower Right X',or 'Upper Left Y' and 'Lower Right Y'
values are the same.
------------------------------
Code: 2300E543
Display: Mark check area is specified at the body center.
Used by:
Cause: Mark check area is specified at the body center.Unable to check the part supply orientation in the
case that the mark check area is specified at the body center.
Remedy: Check the specified coordinates and the area for mark checking.
------------------------------
Code: 2300E571
Display: ElementData is necessary when a Vision Type other than 10, or 18 is used.
Used by:
Cause: There is no ElementData although a Vision Type other than 10 or 18 is specified.
Remedy: Set the ElementData.
------------------------------
Code: 2300E572
Display: Set a value of 1 or above for [Lead Quantity] if the Vision Type is specified as 20, 100, 124, 130,
or 180.
Used by:
Cause: A "Lead Quantity" setting of "0" exists at the ElementData item of the Part Data, even though a
Vision Type of 20, 100, 124, 130, or 180 is specified.
Remedy: Specify a suitable "Lead Quantity" setting.
------------------------------
Code: 2300E573
Display: Set a value of 1 or above for [Lead Length] if the Vision Type is specified as 20, 100, 124, or 180.
Used by:
Cause: A "Lead Length" setting of "0" exists at the ElementData item of the Part Data, even though a
Vision Type of 20, 100, 124, or 180 is specified.
Remedy: Specify a suitable "Lead Length" setting.
------------------------------
Code: 2300E574
Display: Set a value of 1 or above for [Lead Width] if the Vision Type is specified as 20, 100, 124,130 or
180.
Used by:
Cause: A "Lead Width" setting of "0" exists at the ElementData item of the Part Data, even though a
Vision Type of 20, 100, 124,130 or 180 is specified.
Remedy: Specify a suitable "Lead Width" setting.
------------------------------
Code: 2300E575
Display: Vision Type 20 cannot be used for parts with 6 or more leads.
第 2133 页
Used by:
Cause: Vision Type 20 does not allow a "Lead Quantity" setting value of 6 or higher.
Remedy: Either change the Vision Type, or change the "Lead Quantity" setting to a value of 5 or less.
------------------------------
Code: 2300E576
Display: Lead Width is not defined.
Used by:
Cause: A "Lead Width" setting of "0" existed where the Result was other than 128 for the "Element" item
of a Vision Type 230 or 231 part.
Remedy: Specify "Lead Width" settings at lines where the Result is other than 128 for the "Element" item
of a Vision Type 230 or 231 part.
------------------------------
Code: 2300E577
Display: Lead Quantity is not defined.
Used by:
Cause: A "Lead Quantity" setting of "0" existed where the Result was other than 128 for the "Element"
item of a Vision Type 230 or 231 part.
Remedy: Specify "Lead Quantity" settings at lines where the Result is other than 128 for the "Element"
item of a Vision Type 230 or 231 part.
------------------------------
Code: 2300E578
Display: 128 cannot be set at the first line of Result.
Used by:
Cause: A setting of "128" exists at the first Result line for the Element item of a Vision Type 230 or 231
part.
Remedy: Specify a setting other "128" at the first Result line for the Element item of a Vision Type 230 or
231 part.
------------------------------
Code: 2300E579
Display: Result is set to 128 for 2 consecutive element lines.
Used by:
Cause: A setting of "128" exists at two consecutive Result lines for the Element item of a Vision Type 230
or 231 part.
Remedy: Do not specify a "128" setting at two consecutive Result lines for the Element item of a Vision
Type 230 or 231 part.
------------------------------
Code: 2300E57A
Display: When using Vision Type 230 or 231, set the P Pattern to 1 or 2.
Used by:
Cause: For Vision Types 230 and 231, vision processing is only possible when the "P Pattern" is set to 1
or 2.
Remedy: For Vision Types 230 and 231, set the "P Pattern" to 1 or 2.
------------------------------
Code: 2300E57B
Display: 2 Element lines are required for Vision Type 20.
Used by:
Cause: For Vision Type 20, vision processing is only possible when the "Element" setting occupies 2 or
more lines.
Remedy: Specify 2 lines for the "Element" setting. If the Element sides are not facing each other, change
the Vision Type.
------------------------------
第 2134 页