------------------------------ Code: 15040240 Display: Used by: Cause: Remedy: ------------------------------ Code: 15040241 Display: Used by: Cause: Remedy: ------------------------------ Code: 15040242 Display: Used by…
(X0C2) did not deactivate (OFF
) within the specified time limit.
Remedy: Check that the stopper is functioning properly. If the error continues, check that both of the
sensors带幨X0C1, X0C2带幩ar
e functioning properly.
------------------------------
Code: 15040239
Display: In-conveyor panel conveyance error
Used by: CP-752E
Cause: The in-conveyor panel arrival sensor (X0AC) was activated (ON) before the panel speed reduction
sensor (X0AB).
Remedy: Check that the in-conveyor panel speed reduction sensor is functioning properly and confirm the
panel status.
------------------------------
Code: 1504023A
Display: 电路板位置异常 载入侧搬运轨道
Used by: GPX,NXTP
Cause: 在载入侧搬运轨道无法搬运的位置上有电路板。
Remedy: 请除去电路板然后重新放入。
<img src="$LKEY_ERRIMG_MC$/EI0001.bmp">
------------------------------
Code: 1504023B
Display: 载入搬运轨道有电路板错误
Used by: NXTP
Cause: 因为在载入搬运轨道上有电路板,所以不进入到下一步的处理。
Remedy: 请清除电路板。
<img src="$LKEY_ERRIMG_MC$/1504023B.PNG">
------------------------------
Code: 1504023C
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1504023D
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1504023E
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1504023F
Display:
Used by:
Cause:
Remedy:
第 1121 页
------------------------------
Code: 15040240
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 15040241
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 15040242
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 15040243
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 15040301
Display: PCB Loading NG
CHECK PCB
CHECK MAIN-CONVEYOR
Used by: CP3,GSP2,GSP3,IP2,NXTP
Cause: The board cannot be loaded properly.
Remedy: Place the board in its correct position. Check the movement of the stopper at the I/O display
OUT2-26 B_STOPPER_OFF and IN5-19 IN_STOPPER_SW.
------------------------------
Code: 15040302
Display: CHECK LOADER
Used by: CP3
Cause: The loader is not in its original position.
Remedy: Return the loader to its original position.
------------------------------
Code: 15040303
Display: Duplex Loading
Used by: GSP2,GSP3
Cause: Two boards were loaded. The appropriate sensor is connected to IN2-12 DOUBLE_PCB.
Remedy: Remove the boards.
------------------------------
Code: 15040304
Display: Cycle Alarm CLAMP(GSP2)
CYCLE NG Lifter(IP2)
Clamp Error(IP1)
PCB lifter error!(NP2,QP3)
第 1122 页
Used by: GSP2,GSP3,IP1,IP2,NP132,NP133,NP2,QP3
Cause: The board lifter could not clamp or unclamp within the preset time limit.
Remedy: Check to see whether or not there is something interfering with the movement of the clamp.
Adjust the board lifter. Adjust the board lifter's upper and lower limit position.
------------------------------
Code: 15040305
Display: Cycle Alarm PIN
Clamper NG
Used by: GL2,GL5,GL541,IP1,IP2,NP132,NP133
Cause: A reference pin cylinder alarm occurred. The board positioning pin could not enter the reference
hole.
Remedy: Adjust the reference pin cylinder's advance and retract movement. If the pin enters the
reference hole and this message still occurs, check to see that the pin sensor dog moves into the sensor.
------------------------------
Code: 15040306
Display: CHECK FEEDER
Used by: CP3
Cause: The board feeder cylinder could not advance to the arrival position within the preset time.
Remedy: Remove any interfering objects.
------------------------------
Code: 15040307
Display: CHECK TABLE
Lifter Up/Down Error
Used by: CP3
Cause: The table could not raise or lower itself within the preset limits. Something is interfering with the
movement of the XY table.
Remedy: Remove all obstacles to board movement.
------------------------------
Code: 15040308
Display: CHECK JAW
Used by: CP3
Cause: The board feeding pin could not raise or lower itself within the preset time.
Remedy: Remove any obstacles to board movement.
------------------------------
Code: 15040309
Display: TABLE BASE NG
Used by: CP3
Cause: The table base did not move up or down correctly.
Remedy: Check that no parts or garbage is sitting under the parts table. Check IN2-30 TABLE BASE
DWD and IN2-31 TABLE BASE DWN at the I/O display. Also, turn OUT2-2 TABLE BASE DWN on and off
to check the sensor (CP3).
------------------------------
Code: 1504030A
Display: Cycle Alarm Lifter
Lifter
Used by: GL2,GL5,GL541,GSP2,GSP3
Cause: The board lifter could not clamp or unclamp within the preset time limit.
Remedy: Check to see whether or not there is something interfering with the movement of the clamp.
Adjust the board lifter. Adjust the board lifter's upper and lower limit position.
------------------------------
Code: 1504030B