Used by: Cause: When either or both Stage and Slot number is zero, and the device number is also zero, placement cannot be performed as the slot cannot be determined. Remedy: There is a problem with a sequence field in t…

100%1 / 5282
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23050030
Display: No nozzle is registered.
Used by:
Cause: No fields containing data could be found in the second row below the ["BLOCK","SPEC+"] field or
beyond in the XP241 Nozzle Spec. information file (XP241 specified in NZLSPEC/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23050031
Display: The optimized program has not been saved yet. Will you save it?
Used by:
Cause: Attempting to open the program file, but the optimized program has not been saved to the file.
Remedy: Select [Yes] to display the dialog for saving the file with a new name.
Select [No] to abandon the optimized program, and display the dialog for selecting a new program file to be
optimized.
------------------------------
Code: 23050032
Display: The specified program file cannot be found. Search for a file?
Used by:
Cause: The specified program file name does not exist.
Remedy: Select [Yes] to display the dialog for selecting a program file to be read. Select [Abort] to cancel.
------------------------------
Code: 23050033
Display: The specified program file is not a CCIMF file (.pgo). Search for a file?
Used by:
Cause: The specified program file was not a CCIMF file.
Remedy: Select [Yes] to display the dialog for selecting a program file. Select [Abort] to cancel.
------------------------------
Code: 23050034
Display: The amount of nozzle data does not match with the nozzle data fields.
Used by:
Cause: In the Nozzle folder information file, the "NOZZLE","XP241+" field and the item count for the fields
following that field do not match.
Remedy: There is a problem with the program file. Check that the file contents are correct.
------------------------------
Code: 23050035
Display: The nozzle specified by the program file does not exist in Nozzle Configuration File and Nozzle
Specification File.
Do you want to continue?
Used by:
Cause: The nozzle specified in the program does not exist in the Nozzle Config. file and Nozzle Spec. file.
Remedy: Select [Yes] to ignore, and continue reading of the program file. Select [Abort] to cancel reading
of the program file.
------------------------------
Code: 23050036
Display: The following program file sequence's stage and slot No. are set to zero.
第 2157 页
Used by:
Cause: When either or both Stage and Slot number is zero, and the device number is also zero,
placement cannot be performed as the slot cannot be determined.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct. The device number input range is 1 to 500. When specifying a stage - slot arrangement, when
stage 1 is specified, the slot number input range is 1 to 100, and when stage 2 is specified, the slot
number input range is 1 to 400.
------------------------------
Code: 23050037
Display: The program file feeder setup stage and slot No. are set to zero.
Used by:
Cause: When either or both Stage and Slot number is zero, and the device number is also zero, feeders
cannot be allotted as the slot cannot be determined.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct.
The device number input range is 1 to 500.
When specifying a stage - slot arrangement, when stage 1 is specified, the slot number input range is 1 to
100, and when stage 2 is specified, the slot number input range is 1 to 400.
------------------------------
Code: 23050039
Display: No compatible nozzle diameter exists for this part.
Used by:
Cause: When creating the nozzle arrangement automatically, no Nozzle Diameter could be found within
the range defined by Minimum Nozzle Diameter and Maximum Nozzle Diameter in the part data.
Remedy: Try optimizing the program using [Automatic Nozzle Arrangement]. If still unsuccessful, check
the Minimum Nozzle Diameter (PARTS/ENVDT/XP241ENVDT-/PENMI) and Maximum Nozzle Diameter
(PARTS/ENVDT/XP241ENVDT-/PENMA) settings in the part data.
------------------------------
Code: 2305003A
Display: The stage/slot numbers for the following placement sequence in the program file are zero.
Used by:
Cause: Because either the stage or slot number is zero, the device number is referenced for calculation,
however the specified device number is outside the input range of 1 to 500.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct.
The device number input range is 1 to 500.
When specifying a stage - slot arrangement, when stage 1 is specified, the slot number input range is 1 to
100, and when stage 2 is specified, the slot number input range is 1 to 400.
------------------------------
Code: 2305003B
Display: The stage number value in the following sequence in the program file is out of range.
Used by:
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct.
The stage number input range is 1 to 2.
------------------------------
Code: 2305003C
Display: The slot number value in the following sequence in the program file is out of range.
Used by:
Cause: The stage number value is 1, but the slot number value is out of range.
第 2158 页
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct.
When the stage number value is 1, the slot number input range is 1 to 100.
------------------------------
Code: 2305003D
Display: The slot number value in the following sequence in the program file is out of range.
Used by:
Cause: The stage number value is 2, but the slot number value is out of range.
Remedy: There is a problem with a sequence field in the program file. Check that the file contents are
correct.
When the stage number value is 2, the slot number input range is 1 to 400.
------------------------------
Code: 2305003E
Display: The stage/slot numbers for the following feeder setup in the program file are zero.
Used by:
Cause: Because either the stage or slot number is zero, the device number is referenced for calculation,
however the specified device number is outside the input range of 1 to 500.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct.
The device number input range is 1 to 500.
When specifying a stage - slot arrangement, when stage 1 is specified, the slot number input range is 1 to
100, and when stage 2 is specified, the slot number input range is 1 to 400.
------------------------------
Code: 2305003F
Display: The stage number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The slot number value is not zero, but the stage number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct.
The stage number input range is 1 to 2.
------------------------------
Code: 23050040
Display: The slot number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The stage number value is 1, but the slot number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct.
When the stage number value is 1, the slot number input range is 1 to 100.
------------------------------
Code: 23050041
Display: The slot number value in the following feeder setup in the program file is out of range.
Used by:
Cause: The stage number value is 2, but the slot number value is out of range.
Remedy: There is a problem with a feeder setup field in the program file. Check that the file contents are
correct.
When the stage number value is 2, the slot number input range is 1 to 400.
------------------------------
Code: 23050042
Display: Even if nozzle kinds are combined so that the maximum diameter nozzles are not used, there are
too many nozzle kinds to fit in the folder.
Used by: