FUJI错误代码查询.pdf - 第731页
PM?? ERROR Code:******** (QP132) Used by: QP242,QP201,QP202,QP203,QP132 Cause: The machine has received a request, such as an axis movement instruction, that it can't execute because a servo is off. (value replacing…
"No Nozzle Specified in PD" (QP2)
Used by: QP242
Cause: The Proper data does not contain settings for the nozzle specified by the Part data.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the nozzle data in the Device data and the Proper data for the module the caused the
error.
------------------------------
Code: 12070?58
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Desired NSS Occupied" (QP2)
Used by: QP242
Cause: The desired nozzle select station storage location is not available.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the head nozzle and the head nozzle number, then either remove the nozzle from the
desired nozzle select station storage location, or change the head nozzle number.
------------------------------
Code: 12070?59
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Nozzle Orgn Sensor Error" (QP2)
Used by: QP242
Cause: The nozzle check sensor at the nozzle select station is not functioning.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: If the nozzle in question is an index nozzle, the nozzle has not been rotated sufficiently. If it is a
single nozzle, the machine has failed to detect a dropped nozzle. Replace the nozzle in its proper position,
then make sure the nozzle check sensor is functioning normally.
------------------------------
Code: 12070?5A
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Nozzle Check sensor Error" (QP2)
Used by: QP242
Cause: The result of a nozzle check was erroneous.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the head nozzle and the head nozzle number. Make sure the nozzle check sensor is
functioning normally.
------------------------------
Code: 12070?5B
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Operating with Inching Box" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The machine has received a request appropriate to automatic operation or another mode while
being operated from the inching box.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Start automatic operation when inching is complete. If the problem occurs again, use a reset-
start to transmit the control software to the PMC. If the problem is recurring, issues such as a faulty PMC
control board may be the cause.
------------------------------
Code: 12070?5C
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Can't Exe Due to Servo Off" (QP2)
第 730 页
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The machine has received a request, such as an axis movement instruction, that it can't execute
because a servo is off.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?5D
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Valid Only in Manual Mode" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A command that must be received during manual operation has been received while in some
other mode.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?5E
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Can't Receive Due to Load'g" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The machine has received a command that it can't accept while it is loading or unloading boards.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 12070?60
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Process Abort Due to Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The machine has aborted the process being executed because it has received error notification.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: As this is a sub-message, clear the error that caused the interruption.
------------------------------
Code: 12070?61
Display: "ICM(PMC?,SCU?) Error Code:********"
"Not an SPM type memory card"
Used by: QP203
Cause: The SPM was started with an incompatible memory card.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use an SPM memory card to start the machine.
------------------------------
Code: 12070?62
Display: "ICM(PMC?,SCU?) Error Code:********"
第 731 页
"Not an SRM type memory card"
Used by: QP203
Cause: The SRM was started with an incompatible memory card.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use an SRM memory card to start the machine.
------------------------------
Code: 12070?64
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Command was Ignored" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A command was ignored for some reason.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?66
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"PPC data out of range" (QP2)
placing pressure control alarm (QP3)
Used by: QP242,QP3
Cause: The placing pressure set in the Part data is outside the valid placing pressure range for the
specified nozzle.(QP2)
(value replacing "?" is module number; error code appears in place of asterisks)
Place-Pressure is not set in part data or is out of range.(QP3-DM)
The [Placing]-[Pressure] value in part data exceeds the pressure control range for the nozzle
selected.(QP3-MM)
Remedy: Check the placing pressure set in the Part data and the specified nozzle. Check the Proper data
values that set for the placing pressure for the specified nozzle.(QP2)
Set Place-Pressure in part data.(QP3-DM)
Set the [Placing]-[Pressure] value within the range of the specified nozzle or change to a nozzle suitable
for the value.(QP3-MM)
------------------------------
Code: 12070?67
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Nozzle name in PD" (QP2)
Used by: QP242,QP201,QP202,QP203,QP203
Cause: A nozzle name has not been set in the Part data.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: To execute placing pressure control, set the name of the nozzle to be used in the Part data.
------------------------------
Code: 12070?68
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Proper data for PPC" (QP2)
Regular placing pressure control alarm (QP3)
Used by: QP242,QP3
Cause: The Proper data for the nozzle to be used does not include parameters related to placing pressure
control.(QP2)
(value replacing "?" is module number; error code appears in place of asterisks)
第 732 页