FUJI错误代码查询.pdf - 第605页
number has been specified correctly at the [Parts Administration System] setting screen. ------------------------------ Code: 12061041 Display: Feeder type error. Used by: QP3 Cause: In the production program, sub-slot &…
------------------------------
Code: 12061037
Display: RQ-axis START processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: RQ-axis START processing error.
Remedy: If this error occurs frequently, use the machine's trace function to obtain trace data.
------------------------------
Code: 12061038
Display: D1-axis START processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: D1-axis START processing error.
Remedy: If this error occurs frequently, use the machine's trace function to obtain trace data.
------------------------------
Code: 12061039
Display: D2-axis START processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: D2-axis START processing error.
Remedy: If this error occurs frequently, use the machine's trace function to obtain trace data.
------------------------------
Code: 1206103A
Display: NZ-axis START processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: NZ-axis START processing error.
Remedy: If this error occurs frequently, use the machine's trace function to obtain trace data.
------------------------------
Code: 1206103B
Display: D1-axis interlock.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: D1-axis operation will result in interference.
Remedy: Check to see if the pallet stopper on the Stage 1 side is off. Check to see if the Stage 1 pallet
transport sensor is off. Check to see if the Stage 1 pallet DOWN limit sensor is on.
------------------------------
Code: 1206103C
Display: D2-axis interlock.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: D2-axis operation will result in interference.
Remedy: Check to see if the pallet stopper on the Stage 2 side is off. Check to see if the Stage 2 pallet
transport sensor is off. Check to see if the Stage 2 pallet DOWN limit sensor is on.
------------------------------
Code: 1206103D
Display: System processing error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The servo gain parameter management table number for the servo axis in question is incorrect.
Remedy: When this error occurs, use the machine's trace function to obtain trace data.
------------------------------
Code: 1206103F
Display: Sequencer communication error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: Communication is not possible due to a connection error with the feeder verification sensor
monitoring sequencer.
Remedy: Ensure that the communication cable is properly connected, and that the connection port
第 604 页
number has been specified correctly at the [Parts Administration System] setting screen.
------------------------------
Code: 12061041
Display: Feeder type error.
Used by: QP3
Cause: In the production program, sub-slot "1" or "2" has been specified for a feeder on the MFU side of
the machine.
Remedy: As only single feeders can be used on an MFU, set the sub-slot to "0".
------------------------------
Code: 12061043
Display: Feeder ID reader communication error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: Communication is not possible due to a connection error with the Feeder ID 2D code reader.
Remedy: Ensure that the communication cable is properly connected, and that the connection port
number has been specified correctly at the [Parts Administration System] setting screen.
------------------------------
Code: 12061044
Display: Station 1 pickup stopper error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The nozzle is at the lowered position even though the station 1 pickup stopper is engaged.
Remedy: Check the operation of the station 1 stopper at output port Y030.
------------------------------
Code: 12061045
Display: Station 9 pickup stopper error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The nozzle is at the lowered position even though the station 9 pickup stopper is
engaged.Exercise caution as double pl
acement may occur if parts are being held on the nozzles at station 9.
Remedy: Check the operation of the station 1 stopper at output port Y034.
------------------------------
Code: 12061046
Display: Feeder ID reader setting receipt error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: An error occurred while downloading the Feeder ID settings data.
Remedy: Ensure that the communication cable is properly connected.
------------------------------
Code: 12061047
Display: Parts reject error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: The error part was not properly rejected.
Remedy: If the part is still being held by the nozzle at station 9, it should be removed. Adjust the station
13 "kiss-off" valve and the brush on the parts reject tray.
------------------------------
Code: 12061049
Display: Tape cutter not working properly.
Used by: CP-732E, CP-742ME, CP-742E, CP-733E, CP-743ME, CP-743E
Cause: The vertical motion of the tape cutter lever is not smooth.
The mechanical valve on the nozzle shaft may be contacting the pusher on the Station 13 valve switching
lever, which is linked to the tape cutter.
Remedy: Adjust and lubricate the tape cutter lever and Station 13 valve pusher lever assemblies.
------------------------------
第 605 页
Code: 1206104A
Display: NY-axis start processing error
Used by: CP-8Series
Cause: An NY-axis start signal was output while in error status.
Remedy: Correct the cause of the error, and push READY ON.
------------------------------
Code: 1206104C
Display: Outside target position movement range
Used by: CP-8Series
Cause: The target destination of the NY-axis exceeds the plus limit in calibration data.
Remedy: Adjust the NY-axis.
------------------------------
Code: 1206104D
Display: Outside target position movement range
Used by: CP-8Series
Cause: The target destination of the NY-axis exceeds the minus limit in calibration data.
Remedy: Adjust the NY-axis.
------------------------------
Code: 12061050
Display: FQ offset amount error
Used by: CP-732E, CP-742ME, CP-742E, CP-733E, CP-743ME, CP-743E
Cause: The FQ rotation cannot be performed within the permissible cycle time as the Q-direction vision
processing offset amount is too large.
Remedy: Please check the pick-up status of the part.As a preliminary measure, set a value of "20" for the
"Pickup Tolerance" item in part data.
------------------------------
Code: 12061052
Display: A signal was received from Fujitrax Verifier stating that feeder verification was not possible.
Check the feeder for which the LED is illuminated.
Used by: CP43,CP6,CP6M,CP65,CP642,CP642M,CP643,CP643M
Cause: A signal was received from Fujitrax Verifier stating that feeder verification was not possible.
Check the feeder for which the LED is illuminated.
Remedy: Check the error details at the Fujitrax computer and take necessary measures.
------------------------------
Code: 12061053
Display: Nozzle center unmeasured
Used by: CP-732E,CP-742ME,CP-742E,CP-733E,CP-743ME,CP-743E
Cause: Nozzle holder center measurement has not been performed for the holder displayed in the
parameter section after performing part camera calibration data measurement or (X0,Y0) calibration data
measurement. There is a possibility of a drop in accuracy.
Remedy: Attach a 1.0~2.5mm nozzle and perform nozzle holder center measurement.
------------------------------
Code: 12061054
Display: Maintenance key is OFF
Used by: CP-732E,CP-742ME,CP-742E,CP-733E,CP-743ME,CP-743E
Cause: The Maintenance Mode cannot be used because the maintenance key is switched OFF.
Remedy: Switch the maintenance key ON, or exit from the Maintenance Mode panel and push the READY
ON button.
------------------------------
Code: 12061055
Display: Maintenance Mode unavailable
第 606 页