FUJI错误代码查询.pdf - 第611页

Code: 1206201B Display: Tray chute not closed Used by: Cause: The tray chute is not closed. Remedy: Close the tray chute. ------------------------------ Code: 1206201C Display: Rear operation disables inching Used by: Ca…

100%1 / 5282
Used by: IP1,IP3
Cause: The results of nozzle check indicate that the nozzle which was picked up when the machine
operation was cancelled is still in the nozzle station.
Remedy: Check the nozzle station.
------------------------------
Code: 12062015
Display: CHECK FEEDER STATION 1(2)
Used by: IP1
Cause: The feeder parts shuttle is advanced.
Remedy: This is interfering with the nozzle so retract the shuttle at the I/O board. For example, if the
feeder at device 20 is advanced, set the OUT 3-20 PARTS_FEEDER20 I/O setting to off. When the display
is 1, this refers to station 1, and if the display is 2, this refers to station 2.
------------------------------
Code: 12062016
Display: 200V NG
Used by:
Cause: When the start button was pressed to start zero setting, the 200V power supply was not on and
zero setting was not carried out.
Remedy: Check the thermals, circuit protectors, etc. to find the reason the power supply is not on.
------------------------------
Code: 12062017
Display: MAIN CONVEYOR POSITION ERROR
Used by: IP1
Cause: The Y table has moved away from its loading position, so the board cannot be loaded or cleared
off. This error occurs after inching, or after an emergency stop, etc.
Remedy: Inch the Y axis to return the table, or use the [LOADER], [PCBSET] or [CLROFF] command
function keys.
------------------------------
Code: 12062018
Display: Please check I/O NOZZLE STATION
Used by:
Cause: Neither of the nozzle station location sensors are on.
Remedy: Adjust either IN2-27 NOZZLE_R_END or IN2-26 NOZZLE_L_END.
------------------------------
Code: 12062019
Display: CHECK PCB SENSOR
Used by:
Cause: The board arrival sensor or the board deceleration sensor is off. Either the sensor is not adjusted
properly, or the sensor is off because of parts or holes on the board.
Remedy: Inspect the board arrival sensor or the board deceleration sensor. If this error occurs due to
parts or holes in the board, continue production.
------------------------------
Code: 1206201A
Display: Please check I/O
Used by:
Cause: On IP machines where the nozzle station shifts, neither the I/O NOZZLE_R_END nor
NOZZLE_L_END setting is on. On IP machines where the nozzle station does not shift, either the I/O
NOZZLE_R_END or NOZZLE_L_END setting is on.
Remedy: On shift style IP machines, one of them should be on, and on non-shift style machines, they
should both be off.
------------------------------
第 610 页
Code: 1206201B
Display: Tray chute not closed
Used by:
Cause: The tray chute is not closed.
Remedy: Close the tray chute.
------------------------------
Code: 1206201C
Display: Rear operation disables inching
Used by:
Cause: When the operation panel is at the rear, inching was attempted on button 3, and could not be
done.
Remedy: Carry out inching with the panel at the front.
------------------------------
Code: 1206201D
Display: Check Nozzle
Used by:
Cause: Inching was attempted with the nozzle lowered.
Remedy: Raise the nozzles and do the inching.
------------------------------
Code: 1206201E
Display: IP2 ERROR
Used by: IP2
Cause: There was an error in IP2 control program processor.
Remedy: If the problem continues after pressing the reset button, contact Fuji.
------------------------------
Code: 1206201F
Display: MTU not Ready
Used by: IP2
Cause: At the MTU, the preset time has been used but there has been no live marker number entered.
There is an alarm on the MTU.
Remedy: Check that the MTU breaker is not off. Check that the MTU cable is connected properly; turn off
the machine and re-boot. If the problem persists, contact Fuji.
------------------------------
Code: 12062020
Display:
Used by: IP3
Cause: The reject parts conveyor could not start moving.
Remedy: Check the reject parts conveyor.
------------------------------
Code: 12062021
Display: LIGHTING TIME UP
Used by: IP2
Cause: The time limit set for the surface to light has been exceeded.
Remedy: Turn off the power and turn it on again.
------------------------------
Code: 12062022
Display: The [X?-Z? INTERLOCK] sensor is off.
Used by: IP-3
Cause: An attempt was made to move the X-axis when a clearance of 7.5 mm
was not present between the tip of the nozzle and the upper surface of the board.
Remedy: Make adjustments to the [X?-Z? INTERLOCK] sensor or ensure that the
第 611 页
sensor wiring is correctly connected.
------------------------------
Code: 12062023
Display: Station ? Nozzle Rest Not at Retract Limit
Used by: IP-3
Cause: An attempt was made to move the X-axis even though the nozzle changer
was not at the retract position.
Remedy: Ensure that the nozzle changer has been retracted and that the sensor
wiring is correctly connected.
------------------------------
Code: 12063001
Display: "Move squeegee to origin position" (GSP), "Move squeegee to printing start position (GP5, GP6)
Used by: GSP2,GSP3,GP2,GP3
Cause: The machine does not know the printing direction because the squeegee is in the middle of a
print stroke.
Remedy: Move the squeegee to either the right or the left origin point.
------------------------------
Code: 12063002
Display: Error: Not Z_axle Original
Used by:
Cause: The frame was not down when either the screen plate notch was to have been released or caught.
Remedy: Lower the frame. Check the lower edges of the frame.
------------------------------
Code: 12063003
Display: Error: Not Y_axle Original
Used by:
Cause: When the frame is to be lowered, the Y axis did not retract to the safety area.
Remedy: Retract the Y axis until the Y axis safety sensor turns on.
------------------------------
Code: 12063004
Display: EXIST CARRING ON M/C CHECK SENSOR
Used by: GSP2,GSP3
Cause: When a screen change is attempted, at least one of the following conditions arose: the frame set
sensor is on, the frame push sensor is on, the frame supply normal sensor is shaded, the frame X axis
sensor is lighted, the right frame X axis sensor is lighted, the left frame X axis sensor is lighted.
Remedy: Check each sensor
------------------------------
Code: 12063005
Display: Screen In Position
Used by: GSP2,GSP3
Cause: In the case where an attempt was made to move the stencil frame to the print position, a stencil
already existed at the print position and thus supply was not possible. The input signal indicating that no
stencil exists inside the frame, was off. (The light beam of the sensor indicating no stencil inside the frame
had not been cut.) (GSP) The lower-limit sensors of the top stencil clamps were all on. (GP6)
Remedy: Remove the stencil frame from inside the frame. Check the sensors.
------------------------------
Code: 12063006
Display: NOT SCREEN ON FRAME
Used by: GSP2,GSP3
Cause: When the machine attempted to remove a screen from the frame, there was no screen there.
With no screen in the frame the input is on. (The light beam is interrupted.)
第 612 页