Cause: The PMC's reference parts eject position Y is not set. The "?" represents the module number in hexadecimal format. ("0" is PMC 16) Remedy: Set the Proper data item "Parts Eject Pos_Y&…

100%1 / 5282
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?06
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?07
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?08
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?09
Display: Same as Code.
Used by: QP132
Cause: The PMC's reference pick-up position X is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Device Origin D0_X" to the correct value. This Proper data item exists
for each module. Module one is number 719 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?0A
Display: Same as Code.
Used by: QP132
Cause: The PMC's reference pick-up position Y is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Device Origin D0_Y" to the correct value. This Proper data item exists
for each module. Module one is number 720 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?0B
Display: Same as Code.
Used by: QP132
Cause: The PMC's reference parts eject position X is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Parts Eject Pos_X" to the correct value. This Proper data item exists
for each module. Module one is number 721 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?0C
Display: Same as Code.
Used by: QP132
第 178 页
Cause: The PMC's reference parts eject position Y is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Parts Eject Pos_Y" to the correct value. This Proper data item exists
for each module. Module one is number 722 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?0D
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?0E
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?0F
Display: Same as Code.
Used by: QP132
Cause: The PMC's Y-axis retract position is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Escape Pos Y" to the correct value. This Proper data item exists for
each module. Module one is number 724 in Proper data. Thereafter, add (PMC No. -1) times 82 to locate
this item for each module.
------------------------------
Code: 11025?10
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?11
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?12
Display: Same as Code.
Used by: QP132
Cause: The PMC's X-axis extended position is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Max Limit Position X" to the correct value. This Proper data item
exists for each module. Module one is number 728 in Proper data. Thereafter, add (PMC No. -1) times 82
to locate this item for each module.
------------------------------
Code: 11025?13
Display: 11025?13
Used by:
第 179 页
Cause: The maximum pulse count for movement of the PMC X-axis in the minus direction was not
specified.
Remedy: Specify 1058 + offset. Min Limit Position X in Proper data, where offset = (PMC No. - 1)*50)
------------------------------
Code: 11025?14
Display: Same as Code.
Used by: QP132
Cause: The PMC's Y-axis extended position is not set.
Remedy: Set the Proper data item "Max Limit Position Y" to the correct value. This Proper data item exists
for each module. Module one is number 729 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?15
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?16
Display: Data Check Error [11025?16]
Used by: QP132
Cause: The camera center for the AB nozzle and the E nozzle is not set.
Remedy: Perform the Proper data measurement of AB and E nozzles' camera center or check Proper data
items 276?467.
------------------------------
Code: 11025?17
Display: Data Check Error [11025?17]
Used by: QP132
Cause: The camera center for the CD nozzle and the F nozzle is not set.
Remedy: Perform the Proper data measurement of CD and F nozzles' camera center or check Proper data
items 276?467.
------------------------------
Code: 11025?18
Display: Data Check Error [11025?18]
Used by: QP132
Cause: The value for the lean tolerance item is out of range.
"?" indicates the module number in hexadecimal notation. "0" indicates PMC 16.
Remedy: The lean tolerance range for a PMC is -50 to +50 1/1000 deg.
Set the Proper data item "739. Lean offset" (PMC 1) to a value in the range. For other Proper data
numbers (module number - 1) x 82.
------------------------------
Code: 11032000
Display:
Used by: GL2,GL5,GL541,GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6,IP1,IP3
Cause: Status data's Error setting is out of range.
Remedy: Check the Error setting in Status data.
------------------------------
Code: 11032001
Display:
Used by: IP1
Cause: Status data's Recovery_count setting is out of range.