Cause: Devices cannot be satisfactorily arranged at the IP3. Remedy: There are devices in the source program that cannot be placed to the IP3. Fix these at the editor and reboot. ------------------------------ Code: 2100…
Code: 21006099
Display: Nozzle information table memory allocation error
Used by:
Cause: The nozzle information table memory could not be allocated correctly.
Remedy: Reboot MCS.
------------------------------
Code: 2100609A
Display: Tray information table memory allocation error
Used by:
Cause: The tray information table memory could not be allocated correctly.
Remedy: Reboot MCS.
------------------------------
Code: 2100609B
Display: Nozzle information file open error
Used by:
Cause: The nozzle information file could not be opened.
Remedy: Try opening a file that exists.
------------------------------
Code: 2100609C
Display: Tray information file open error
Used by:
Cause: The tray information file could not be opened.
Remedy: Try opening a file that exists.
------------------------------
Code: 2100609D
Display: Nozzle information file read error
Used by:
Cause: The nozzle information file could not be read.
Remedy: Fix the file using the editor.
------------------------------
Code: 2100609E
Display: Tray information file read error
Used by:
Cause: The tray information file could not be read.
Remedy: Fix the file using the editor.
------------------------------
Code: 2100609F
Display: Nozzle information file type missmatch
Used by:
Cause: Nozzle information file type is mismatched.
Remedy: Specify the nozzle information in the nozzle information file.
------------------------------
Code: 210060A0
Display: Tray information file type missmatch
Used by:
Cause: Tray information file type is mismatched.
Remedy: Specify the tray information in the tray information file.
------------------------------
Code: 210060A1
Display: Machine fip3 arranged check error
Used by:
第 1905 页
Cause: Devices cannot be satisfactorily arranged at the IP3.
Remedy: There are devices in the source program that cannot be placed to the IP3. Fix these at the editor
and reboot.
------------------------------
Code: 210060A2
Display: Information table memory allocation error
Used by:
Cause: The IP3 information table could not be saved.
Remedy: Reboot MCS.
------------------------------
Code: 210060A3
Display: GL_generator error abort
Used by:
Cause: GL generation was aborted due to an error.
Remedy: Proceed depending on the error which occurred during GL generation.
------------------------------
Code: 210060A4
Display: "M/C Nickname is duplicated."
Used by:
Cause: The same machine nickname has been registered more than once in the line descriptor or the
offline descriptor.
Remedy: Make sure that the same machine nickname is not duplicated in the line descriptor or the offline
descriptor.
------------------------------
Code: 210060A5
Display: "M/C type is not specified."
Used by:
Cause: The offline descriptor contains a machine type that does not correspond to any of the machine
types defined in MCS/2.
Remedy: Change the machine type in the offline descriptor to one defined in MCS/2. Refer to the MCS/2
manual for details on defined machine types.
------------------------------
Code: 210060A6
Display: "Feeder specified as "Fix" in PT file can't be used."
Used by:
Cause: A feeder specified as a fixed device in the PST file cannot be used on the machine for which
separation is being performed.
Remedy: Change the feeder type in the relevant device comment to one that can be used by the machine
specified in the PST file.
------------------------------
Code: 210060A7
Display: "Feeder type for comment isn't specified in PT file."
Used by:
Cause: The feeder type cannot be determined, because the feeder type has not been entered in the device
comment field of the PST file. The feeder type will be determined based on the Part data.
Remedy: Enter the feeder type in the relevant device comment field of the PST file.
------------------------------
Code: 210060A8
Display: "Feeder position in PT file is out of range."
Used by:
Cause: A feeder position specified as fixed in the PST file is outside the feeder station range. The device
第 1906 页
comment in question will be separated as a non-fixed feeder.
Remedy: Specify a feeder position within the feeder station's range.
------------------------------
Code: 210060A9
Display: "There is insufficient space for a feeder in PT file."
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred when the feeder width was checked against the end of the station. The feeder in question will be
separated as a non-fixed feeder.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 210060AA
Display: "Space between feeders in PT file is insufficient."
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred due to interference between feeders.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21006400
Display: syntax error - illegal '+' option
Used by:
Cause: An illegal '+' option was specified at start-up.
Remedy: Check the specified option.
------------------------------
Code: 21006401
Display: can't read strings file
Used by:
Cause: The string file couldn't be loaded into the memory.
Remedy: Re-install the software.
------------------------------
Code: 21006402
Display: program file not found
Used by:
Cause: The specified production program name was not found.
Remedy: Check the production programs.
------------------------------
Code: 21006403
Display: change console path error
Used by:
Cause: During operation, the specified terminal path could not be changed.
Remedy: Re-boot MCS.
------------------------------
Code: 21006404
Display: CRT event link error
Used by:
Cause: The terminal event could not be linked.
Remedy: Re-boot MCS.
------------------------------
Code: 21006405
Display: can't fork Ls task
Used by:
第 1907 页