Remedy: If the machine type is correct, re-install the software. ------------------------------ Code: 21007523 Display: Index file open error Used by: Cause: Unable to open the index file. Remedy: Re-install the software…

100%1 / 5282
Display: Queueing error
Used by:
Cause: Unable to queue data.
Remedy: Re-boot MCS.
------------------------------
Code: 2100751B
Display: PT file not found
Used by:
Cause: The PST file was not found.
Remedy: Check the input filename.
------------------------------
Code: 2100751C
Display: PTT file open error
Used by:
Cause: Unable to read the PST file.
Remedy: Check the file.
------------------------------
Code: 2100751D
Display: Offset table read error
Used by:
Cause: Unable to read the file.
Remedy: Check the file and save it.
------------------------------
Code: 2100751E
Display: PT file read error
Used by:
Cause: Unable to read Permanent Set Table file.
Remedy: Check the file and save the changes.
------------------------------
Code: 2100751F
Display: Output file not found
Used by:
Cause: The output file does not exist.
Remedy: Re-start the MCS.
------------------------------
Code: 21007520
Display: Output file open error
Used by:
Cause: Unable to open the output file.
Remedy: Check that the file write protect setting is not on.
------------------------------
Code: 21007521
Display: Production file write err
Used by:
Cause: Unable to write to the file.
Remedy: Check that the file write protect setting is not on.
------------------------------
Code: 21007522
Display: Index file not found
Used by:
Cause: The index file was not found.
第 1941 页
Remedy: If the machine type is correct, re-install the software.
------------------------------
Code: 21007523
Display: Index file open error
Used by:
Cause: Unable to open the index file.
Remedy: Re-install the software.
------------------------------
Code: 21007524
Display: Strategy file get error
Used by:
Cause: Unable to read the system (strategy) file.
Remedy: Re-install the software.
------------------------------
Code: 21007525
Display: Make not mark sequence
Used by:
Cause: A mark sequence was not created.
Remedy: This message occurs when there is a program without a mark sequence.
------------------------------
Code: 21007526
Display: Station over
Used by:
Cause: The device could not be placed on the station.
Remedy: Join the feeder. Alternately, stop using the PST and the base program.
------------------------------
Code: 21007527
Display: Occupancy error
Used by:
Cause: An attempt was made to place a fixed device where it could not be placed.
Remedy: Depending on the feeder width, there are cases where the feeders cannot be placed next to each
other. Change the location.
------------------------------
Code: 21007528
Display: Slot info read error
Used by:
Cause: Unable to read the information.
Remedy: Re-install the software.
------------------------------
Code: 21007529
Display: Occupancy data not found
Used by:
Cause: Unable to read the information.
Remedy: Re-install the software.
------------------------------
Code: 2100752A
Display: Part data open error
Used by:
Cause: Unable to open Part data.
Remedy: Check the file.
------------------------------
第 1942 页
Code: 2100752B
Display: Part data read error
Used by:
Cause: Unable to read Part data.
Remedy: Check the file.
------------------------------
Code: 2100752C
Display: File read error
Used by:
Cause: Unable to read input file.
Remedy: Check the file.
------------------------------
Code: 2100752D
Display: File offset get error
Used by:
Cause: Unable to read the input file.
Remedy: Check the file and save the changes.
------------------------------
Code: 2100752E
Display: Can not feedback Fix device
Used by:
Cause: The specified device number for the fixed device is wrong.
Remedy: Check the PST file device numbers.
------------------------------
Code: 2100752F
Display: Skip device station over
Used by:
Cause: Unable to mount skip device.
Remedy: There are too many devices, so the skip device cannot be mounted. Reduce the number of
devices.
------------------------------
Code: 21007530
Display: Next device station over
Used by:
Cause: Unable to mount next device.
Remedy: There are too many devices, so the next device cannot be mounted. Reduce the number of
devices.
------------------------------
Code: 21007531
Display: New prodction file has no sequence data
Used by:
Cause: The new production program has no sequence data.
Remedy: Check the program's sequence data.
------------------------------
Code: 21007532
Display: Input program file name is too long
Used by:
Cause: Input program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007533