------------------------------ Code: 2300E116 Display: The mark name is not specified. Used by: Cause: The mark name field in the mark sequence is blank. Remedy: Specify the mark name to match the existing mark data. ---…

100%1 / 5282
stage and slot number.
Used by:
Cause: Sequence data with and without feeder skip settings exist for the same stage/slot number.
Remedy: Correct the sequence data so that all sequences for the same stage/slot number have the same
feeder skip settings.
------------------------------
Code: 2300E110
Display: The total number of board skip mark read sequences and fiducial mark read sequences exceeds
255.
Used by:
Cause: The total number of board skip mark read sequences and fiducial mark read sequences exceeds
255.
Remedy: Correct the sequence data so that the total number of board skip mark read sequences
(Sequence type:B) and fiducial mark read sequences (Sequence type:F) is 255 or less.
------------------------------
Code: 2300E111
Display: The "Sequence Comment" sequence specified for the "Place Before" sequence does not exist on the
same board.
Used by:
Cause: The "Sequence Comment" sequence specified for the "Place Before" sequence does not exist on the
same board.
Remedy: Specify a "Sequence Comment" sequence that applies to the same board as that of the "Place
Before" sequence.
The "Place Before" sequence is ignored where the "Sequence Comment" sequence does not apply to the
same board.
------------------------------
Code: 2300E112
Display: The same name has been allocated to "Place Before" and "Sequence Comment".
Used by:
Cause: The same name has been allocated to the "Place Before" and "Sequence Comment" sequences.
Remedy: Specify different names for the "Place Before" and "Sequence Comment" sequences.
------------------------------
Code: 2300E113
Display: Duplicate "Sequence Comment" sequences exist for the same board.
Used by:
Cause: Duplicate "Sequence Comment" sequences exist for the same board.
Remedy: Create sequences so that "Sequence Comment" sequences are not duplicated for the same
board.
------------------------------
Code: 2300E114
Display: The "Place Before" sequence order is incorrect.
Used by:
Cause: The "Place Before" sequence order is incorrect.
Remedy: Change the "Place Before" sequence order so that the "Place Before" sequence is positioned
before the "Sequence Comment" sequence.
------------------------------
Code: 2300E115
Display: Mark data does not exist for the specified mark name.
Used by:
Cause: Either the mark name is input incorrectly in the sequence data, or the mark data does not exist.
Remedy: Check the mark data. If mark data does exist, then check the mark name in the sequence data.
第 2128 页
------------------------------
Code: 2300E116
Display: The mark name is not specified.
Used by:
Cause: The mark name field in the mark sequence is blank.
Remedy: Specify the mark name to match the existing mark data.
------------------------------
Code: 2300E117
Display: The mark name is not specified. The No. 1 mark from the mark edit screen is being used.
Used by:
Cause: A mark name has not been specified in the sequence editor screen. The No. 1, type F mark from
the mark editor screen is being used.
Remedy: If there is a problem with the mark being used, then specify a different mark name in the
sequence edit screen.
------------------------------
Code: 2300E118
Display: The global skip mark sequence must be positioned earlier in the program than the board skip
mark sequence.
Used by:
Cause: The global skip mark sequence must be positioned earlier in the program than the board skip
mark sequence.
Remedy: Input the global skip mark sequence at an earlier sequence no. than the board skip mark
sequence.
------------------------------
Code: 2300E119
Display: When referencing fiducial marks for global / board skip mark sequences, the board no. for the
fiducial mark sequence must be 0.
Used by:
Cause: When referencing fiducial marks for global / board skip mark sequences, the board no. for the
fiducial mark sequence must be 0.
Remedy: Set the board no. for a fiducial mark sequence to 0 when referencing fiducial marks for global /
board skip mark sequences.
------------------------------
Code: 2300E11A
Display: The fiducial mark sequence must be positioned earlier in the program than the global / board
skip mark sequence.
Used by:
Cause: The fiducial mark sequence must be positioned earlier in the program than the global / board
skip mark sequence.
Remedy: Input the fiducial mark sequence at an earlier sequence no. than the global / board skip mark
sequence.
------------------------------
Code: 2300E11B
Display: A board skip mark sequence for a particular board no. must be positioned earlier in the program
than any placement sequences for that board.
Used by:
Cause: A board skip mark sequence for a particular board no. must be positioned earlier in the program
than any placement sequences for that board.
Remedy: Input the board skip mark sequence for a particular board no. at an earlier sequence no. than
any placement sequences for that board.
------------------------------
第 2129 页
Code: 2300E11C
Display: The main and sub marks are too close together.
Used by:
Cause: Unable to correct placement because the main and sub marks are too close together.
Remedy: Revise the mark settings or to separate the main and sub marks by at least 5 mm.
------------------------------
Code: 2300E11D
Display: Another group skip mark sequence has the same mark number.
Used by:
Cause: Another group skip mark sequence has the same mark number.
Remedy: Change the mark number.
------------------------------
Code: 2300E11E
Display: There is a group skip mark sequence after a board skip mark sequence.
Used by:
Cause: The insertion order is incorrect.There is a group skip mark sequence after a board skip mark
sequence.
Remedy: Change the insert order so that group skip mark sequences are before board skip mark
sequences.
------------------------------
Code: 2300E11F
Display: There is a global skip mark sequence after a group skip or board skip mark sequence.
Used by:
Cause: The insertion order is incorrect.There is a global skip mark sequence after a group skip or board
skip mark sequence.
Remedy: Change the insert order so that global skip sequences are before group skip mark sequences and
board skip mark sequences.
------------------------------
Code: 2300E120
Display: To reference a fiducial mark,a fiducial mark whose board number 0 is required.
Used by:
Cause: When referencing a fiducial mark for a global skip mark,group skip mark,or board skip mark,a
fiducial mark whose board number is 0 is required.
Remedy: Create a fiducial mark sequence whose board number is 0.
------------------------------
Code: 2300E121
Display: The reference fiducial mark is after the current sequence.
Used by:
Cause: The insertion order is incorrect.The reference fiducial mark is after the current sequence.
Remedy: Change the insert order so that the reference fiducial mark is before the indicated sequence.
------------------------------
Code: 2300E201
Display: The Program polarity item's [No] setting is not supported.
Used by:
Cause: XP-series machines do not support Program Polarity's "No" setting.q宝xcept for program data
transmitted from MCS/2q搽Remedy: Set the Program Polarity setting to "Yes".
Remedy: Set the Program Polarity setting to "Yes".
------------------------------
Code: 2300E202
Display: The Program Polarity setting [No] in the production program which was transmitted from the
MCS/2 to the XP-141E is not supported.