FUJI错误代码查询.pdf - 第1112页

------------------------------ Code: 15040101 Display: Emergency Stop Used by: Cause: The emergency stop button was pressed (when using peripherals this message can occur if the safety door has been opened). Remedy: Afte…

100%1 / 5282
Code: 1503400D
Display: XY-table dwn lmt sensor has not come ON
Used by: CP643
Cause: The XY-table has been lowered,but the main conveyor lower limit sensor
hane not turned ON.
Remedy: Check the main conveyor lower limit sensors (X067).
------------------------------
Code: 1503400E
Display: Interlock alarm:I_CRRY
In-carrier not clamped
Used by: CP643
Cause: The in-carrier extended limit claws closed sensors (LX042,LX043) have not turned ON when the
XY-table is at height ZL-7 mm while loading or unloading a board.
Remedy: Check the in-carrier extended limit claws closed sensors (LX042,LX043).
------------------------------
Code: 1503400F
Display: Interlock alarm:O_CRRY
Out-carrier not clamped
Used by: CP643
Cause: The out-carrier extended limit claws closed sensors (LX048,LX049) have
not turned ON when the XY-table is at height ZL-7 mm while loading or unloading
a board.
Remedy: Check the out-carrier extended limit claws closed sensors (LX048,LX049).
------------------------------
Code: 15034010
Display: XY-table dwn lmt sensor has not come OFF
Used by: CP643
Cause: The XY-table was raised,but the main conveyor lower limit sensor hane not turned OFF.
Remedy: Check the main conveyor lower limit sensors (X067).
------------------------------
Code: 15034011
Display: Middle loading pos. error. Check sensor and Prop. data.
Used by: CP643
Cause: The main conveyor attempted to move over the middle loading position, but the middle loading
position sensor was off, or the Z-axis was outside the Proper data range.
Remedy: The axis cannot move if the middle loading position sensor is on and the Z-axis is not within the
range specified in Proper data (+50 pulse/-100 pulse). Check the position of the sensor, and the Proper
data settings.
------------------------------
Code: 15040001
Display: Check Loader
Used by: IP2
Cause: The board detection sensor between the main, in or out conveyors was activated.
Remedy: Check the position of the board on the loader. If the conveyor is caught in the Y axis, return it
to its correct position.
------------------------------
Code: 15040002
Display: Cycle Alarm PCB Loading
Used by:
Cause: A board loading alarm occurred.
Remedy: Check the board which is being loaded.
第 1111 页
------------------------------
Code: 15040101
Display: Emergency Stop
Used by:
Cause: The emergency stop button was pressed (when using peripherals this message can occur if the
safety door has been opened).
Remedy: After resetting the emergency stop button (or closing the safety door), press the reset button.
------------------------------
Code: 15040102
Display:
Used by:
Cause: The board was supposed to be unloaded from the MCID but the board did not reach the board
arrival sensor within the specified time.
Remedy: Check that the board is not stuck on the conveyor.
------------------------------
Code: 15040103
Display: "PCB Stopper Error MCID"
Used by:
Cause: MCID stopper cycle error. The stopper ON or OFF check sensor did not turn on within three
seconds (on the QP2) after an instruction to raise or lower the board stopper was issued.
Remedy: Check whether stopper operation is being prevented by an obstacle (such as a board). If so,
remove the obstacle. If not, perform an I/O check to make sure the stopper ON and OFF check sensors
are functioning normally.
------------------------------
Code: 15040201
Display: IN CONVEYOR NG
Used by: IP1
Cause: While in automatic operation, a board stuck out of the in-conveyor (IP1).
Remedy: Check the board on the in-conveyor. Alternately, adjust the in-conveyor board arrival sensor
and the in-conveyor board pass sensor.
------------------------------
Code: 15040202
Display: Cycle Alarm Loading Error
Loading Error
Used by: GL2,GSP2,GSP3,NP132,NP133
Cause: A board got caught while being loaded onto the in-conveyor, causing this alarm. After a board
was unloaded from the in-conveyor, it did not arrive at the main conveyor within the preset time limit.
When MCID is being used, this code can occur after the MCID conveyor and the in-conveyor (GSP). When
a board was sent to the main conveyor from the in-conveyor, it was stopped en route. Alternately, the
borad detection sensors at the in-conveyor or the main conveyor are not working correctly (the in sensor is
on or the main sensor is off).
Remedy: Check that the board is not stuck on the conveyor. If the machine thinks that the board has
been moved from its correct position, remove that board.
------------------------------
Code: 15040203
Display: CHECK INB STOPPER
Used by: CP3,QP242,NP132,NP133
Cause: The in-conveyor in B stopper cannot raise or lower itself within the preset time.
Remedy: Check that there is no board stuck between the in B conveyor and the main conveyor. Use the
I/O to check OUT2-26 B_STOPPER_OFF by toggling OUT2-26 B_STOPPER_OFF by toggling this on and
off, and check the input conditions at IN5-19 IN_STOPPER_SW.
第 1112 页
------------------------------
Code: 15040204
Display:
Used by: QP242,QP201,QP202,QP203,IP1
Cause: The board was supposed to be unloaded from the in conveyor but the board did not reach the
board arrival sensor within the specified time.
Remedy: Check that the board is not stuck on the conveyor.
------------------------------
Code: 15040205
Display: 电路板搬运错误IN
载入侧的电路板搬运异常(QP132)
电路板载入异常(NP2,QP3)加载装置错误: 15040205
Used by: QP132,NP132,NP133,NP2,QP3,GPX,NXTP
Cause: 来自前行程的电路板从搬运轨道减速开始点开始在一定时间内没有到达。请确认是否在从减速开始点到确认
传感器的之间停止了。
在减速开始点到确认传感器的之间发生了电路板载入超时。(NP2,QP3) 在前工序排出电路板之后的预定时间内
,电路板没有到达主搬运轨道。(GPX)
Remedy: 请通过I/O进行载入侧搬运轨道电路板到达确认(X041:IN ARRV CHK)或载入侧搬运轨道减速开始点
(X040:IN DECEL PNT)的动作确认及调整。
请保证电路板搬运能够顺畅地进行。(NP2,QP3) 1.请确认搬运轨道上电路板是否被卡住了。
2.可认为电路板偏离了正常位置,请除去被认为发生了异常的电路板。
3.请确认搬运轨道间的电路板取入是否能顺畅地进行。
3-1.搬运轨道宽度的再调整
3-2.搬运轨道搬入高度的再调整
4.电路板重(请与本公司的Support联系)
5.电路板薄导致被夹入在搬运轨道皮带和轨道之间(请与本公司的Support联系)
8.到达传感器的故障(请与本公司的Support联系)
9.通孔导致的电路板检测困难(请利用停止块偏移设置)
10.电路板的切口(请利用停止块偏移设置)
11.从主搬运轨道排出时,存在电路板粘在钢板上的可能性。请确认。(GPX)
如果不打开前门进行有无电路板的确认,就不能解除错误。(GPX)
<img src="$LKEY_ERRIMG_MC$/15040205.PNG">
------------------------------
Code: 15040206
Display: 电路板搬送错误 :IN/PCB Transport Error:IN(QP1)
电路板载入侧异常(QP3)
Used by: QP132,QP3,NXTP
Cause: SMEMA规格时进行电路板要求后,即使经过一定时间(30秒)电路板也不到达。载入搬运轨道速度降低开始点
(X040:IN DECEL PNT)不处于ON
从前道工序到开始降低速度点之间电路板载入侧发生了暂停。(QP3)
从前道工序到PREV-IN换乘传感器为止电路板没到达。(NXTP)
Remedy: 请确认电路板的挂住·落下,确认传感器灵敏度。
请确认从前道工序排出的电路板是否顺畅地进行。(QP3)
1.请确认搬运轨道间的电路板载入侧是否顺畅。(NXTP)
2.请确认IN到达传感器(RX04A)是否能正常检测电路板。(NXTP)
<img src="$LKEY_ERRIMG_MC$/15040206.PNG">
------------------------------
Code: 15040207
Display: IN CVYOR INTERLOCK
Used by: NP132,NP133
Cause: The board on the in-conveyor is protruding onto the pallet loader.
第 1113 页