FUJI错误代码查询.pdf - 第1961页

Display: File data type unmatch. Used by: Cause: The input program data type is inappropriate. Remedy: Check the file. ------------------------------ Code: 2100772A Display: File machine type unmatch Used by: Cause: The …

100%1 / 5282
Remedy: Re-execute the function. If the error recurs, re-boot MCS.
------------------------------
Code: 21007721
Display: Write pipe create error
Used by:
Cause: Unable to create the pipe.
Remedy: Re-execute the function. If the error recurs, re-boot MCS.
------------------------------
Code: 21007722
Display: Dequeuing error
Used by:
Cause: Unable to dequeue the memory.
Remedy: Re-boot MCS.
------------------------------
Code: 21007723
Display: Queing error
Used by:
Cause: Unable to process the memory.
Remedy: Re-boot MCS.
------------------------------
Code: 21007724
Display: Que data moving error
Used by:
Cause: Unable to process the memory.
Remedy: Re-boot MCS.
------------------------------
Code: 21007725
Display: Strategy file read error
Used by:
Cause: Unable to read the system (strategy) file.
Remedy: Re-install the software.
------------------------------
Code: 21007726
Display: Make not mark sequence
Used by:
Cause: Special sequences were not created.
Remedy: This warning message displays when there is an input program without special sequences.
------------------------------
Code: 21007727
Display: No entry Input file name
Used by:
Cause: The input program filename has not been input.
Remedy: Input the filename.
------------------------------
Code: 21007728
Display: Output file already exist
Used by:
Cause: An output file with the same name already exists.
Remedy: Either change the name of the output file, or overwrite the old file.
------------------------------
Code: 21007729
第 1960 页
Display: File data type unmatch.
Used by:
Cause: The input program data type is inappropriate.
Remedy: Check the file.
------------------------------
Code: 2100772A
Display: File machine type unmatch
Used by:
Cause: The input program data type is inappropriate.
Remedy: Check the file.
------------------------------
Code: 2100772B
Display: Production file expand error
Used by:
Cause: During expansion of the input program, an error occurred.
Remedy: Use [Cntrl] + [E] to check the contents of the expander.
------------------------------
Code: 2100772C
Display: Not get Part data file name
Used by:
Cause: A Part data name is not entered in the device number being used in Sequence data.
Remedy: Check the Part data name in the production program device data.
------------------------------
Code: 2100772D
Display: Not get Nozzle assignment table file name
Used by:
Cause: The nozzle table file name was not entered in the production program.
Remedy: Input the table file name.
------------------------------
Code: 2100772E
Display: Not get nozzle size
Used by:
Cause: The nozzle size cannot be called up.
Remedy: Check the nozzle table.
------------------------------
Code: 2100772F
Display: Same davice comment entry in PST file
Used by:
Cause: A device comment with the same name exists in the PST file.
Remedy: The same name cannot be used. Change the comment.
------------------------------
Code: 21007730
Display: No entry Cartridge name in PST file
Used by:
Cause: The feeder name has not been entered in the PST file.
Remedy: Input the feeder name.
------------------------------
Code: 21007731
Display: Can not feedback Fix device
Used by:
Cause: Unable to feed back the fixed device. The fixed device's device number is incorrect.
第 1961 页
Remedy: Check the PST file device number.
------------------------------
Code: 21007732
Display: Cartridge type unmatch
Used by:
Cause: The feeder type is incorrect.
Remedy: Check the feeder type.
------------------------------
Code: 21007733
Display: No used Cartridge
Used by:
Cause: An unused feeder exists.
Remedy: Check the file.
------------------------------
Code: 21007734
Display: Can not setting Fix device data
Used by:
Cause: Unable to set the fixed device number.
Remedy: Check the PST file device number.
------------------------------
Code: 21007735
Display: Can not setting Next device data
Used by:
Cause: As there are too many devices in use, the next device cannot be set.
Remedy: Reduce the number of devices in use.
------------------------------
Code: 21007736
Display: Next device change station
Used by:
Cause: The next device is on a different pallet from the original device.
Remedy: This message occurs when the next device is on a different pallet from the original device. Set
the next device on the same pallet.
------------------------------
Code: 21007737
Display: Not found next device
Used by:
Cause: The next device was not found.
Remedy: This warning message appears when there is no next device specified in the program.
------------------------------
Code: 21007738
Display: Not get Cartridge name
Used by:
Cause: Unable to retrieve the feeder name.
Remedy: Check that the Part data has been entered correctly.
------------------------------
Code: 21007739
Display: Station over
Used by:
Cause: The device cannot be placed in the station.
Remedy: Join the feeders. Alternately, stop using the PST or the base program.
------------------------------
第 1962 页