FUJI错误代码查询.pdf - 第2282页
Used by: Cause: Multiple"BLOCK","SOLCO"sections are defined under"UNIT","PROGRAM"of the specified production program. This is reported only at the default check. Remedy: Check the …
there.
------------------------------
Code: 52??1153
Display: No data in"ELEMENT"under"BLOCK","SOLDER".
Used by:
Cause: No data exists for item"ELEMENT"under"BLOCK","SOLDER". This was determined
when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check item"ELEMENT"under"BLOCK","SOLDER"of"UNIT","PROGRAM"in the production
program. At least one line of data must be input for the item"ELEMENT"under"BLOCK","SOLDER". Since
the name of the block("SOLDER")and the value of the item"ELEMENT"are generally reported in
supplemental data,check there.
------------------------------
Code: 52??1154
Display: "ELEMENT"format error under"BLOCK","SOLDER".
Used by:
Cause: A format error was discovered at the reading of"ELEMENT"data
under"BLOCK","SOLDER"when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check the"ELEMENT"data settings under"BLOCK","SOLDER"of"UNIT","PROGRAM"in the
production program. Since the name of the block("SOLDER")and the value of the item"ELEMENT"are
generally reported in supplemental data,check there.
------------------------------
Code: 52??1155
Display: "GCCGSSN"not defined.
Used by:
Cause: There is no"GCCGSSN"definition in the"ELEMENT"item delcaration line
under"BLOCK","SOLDER". This was determined when"UNIT","PROGRAM"of the specified production
program was read.
Remedy: Check the settings for item"ELEMENT"under"BLOCK","SOLDER"of"UNIT","PROGRAM".
The"GCCGSSN"item setting is required. Since the name of the block("SOLDER")and the value of the
item"ELEMENT"are generally reported in supplemental data,check there.
------------------------------
Code: 52??1156
Display: Missing number in"GCCGSSN".
Used by:
Cause: There is a missing number in the"GCCGSSN"item of the"ELEMENT"item
under"BLOCK","SOLDER". This was determined when"UNIT","PROGRAM"of the specified production
program was read.
Remedy: Check the"ELEMENT"item under"BLOCK","SOLDER"of"UNIT","PROGRAM". The"GCCGSSN"item
must have values set from 1 to the final number in sequential order. Since the name of the
block("SOLDER")and the value of the item"ELEMENT"are generally reported in supplemental data,check
there. Missing numbers are also reported at the default check.
------------------------------
Code: 52??1160
Display: No"BLOCK","SOLCO"under"UNIT","PROGRAM".
Used by:
Cause: "BLOCK","SOLCO"was not found under"UNIT","PROGRAM"of the specified production program.
Remedy: Check the settings made for"BLOCK","SOLCO"under"UNIT","PROGRAM"of the production
program.
------------------------------
Code: 52??1161
Display: Multiple"BLOCK","SOLCO"sections.
第 2281 页
Used by:
Cause: Multiple"BLOCK","SOLCO"sections are defined under"UNIT","PROGRAM"of the specified
production program. This is reported only at the default check.
Remedy: Check the settings made for"BLOCK","SOLCO"under"UNIT","PROGRAM"of the production
program.
------------------------------
Code: 52??1162
Display: There is no"ELEMENT"in"BLOCK","SOLCO".
Used by:
Cause: The item"ELEMENT"under"BLOCK","SOLCO"does not exist. This was determined
when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check the settings under"BLOCK","SOLCO"under"UNIT","PROGRAM"of the production program.
------------------------------
Code: 52??1163
Display: Multiple"ELEMENT"under"BLOCK","SOLCO".
Used by:
Cause: The values within the specified item"ELEMENT"under"BLOCK","SOLCO"are the same. This was
determined when"UNIT","PROGRAM"of the specified production program was read. This is reported only at
the default check.
Remedy: Check the settings for item"ELEMENT"under"BLOCK","SOLCO"of"UNIT","PROGRAM"of the
production program. Since the name of the block("SOLCO")of the specified"ELEMENT"item and the value
of the item"ELEMENT"where the error occurs is generally recorded in supplemental data,check there.
------------------------------
Code: 52??1170
Display: The corresponding"SOLCO"data is not found.
Used by:
Cause: The data to be referenced by the sequence data specified in the
item"ELEMENT"under"BLOCK","SOLCO"does not exist. This was determined when"UNIT","PROGRAM"of
the specified production program was read.
Remedy: Check the settings for the item"ELEMENT"under"BLOCK","SOLCO"of"UNIT","PROGRAM"in the
production program. Since the name of the block("SOLCO")and the value of the item"ELEMENT"which is
referenced by the sequence data is generally recorded in supplemental data,check there.
Additionally,check the relating references of the"SOLCO"data
under"BLOCK","SEQUENCE+"of"UNIT","PROGRAM".
------------------------------
Code: 52??1171
Display: No item definition lines in item"ELMENT"under"BLOCK","SOLCO".
Used by:
Cause: There are no item definition lines in the specified item "ELEMENT"under"BLOCK","SOLCO". This
was determined when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check the settings for the item"ELEMENT"under"BLOCK","SOLCO"of"UNIT","PROGRAM"in the
production program. Since the name of the block("SOLCO")and the value of the item"ELEMENT"are
generally reported in supplemental data,check there.
------------------------------
Code: 52??1172
Display: "ELEMENT"item definition format error under"BLOCK","SOLCO".
Used by:
Cause: A format error was discovered in the"ELEMENT"item definition lines
under"BLOCK","SOLCO"when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check the"ELEMENT"item definition line settings
under"BLOCK","SOLCO"of"UNIT","PROGRAM"in the production program. Since the name of the
第 2282 页
block("SOLCO")and the value of the item"ELEMENT"are generally reported in supplemental data,check
there.
------------------------------
Code: 52??1173
Display: No data in "ELEMENT"under"BLOCK","SOLCO".
Used by:
Cause: No data exists for item"ELEMENT"under"BLOCK","SOLCO". This was determined
when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check item"ELEMENT"under"BLOCK","SOLCO"of"UNIT","PROGRAM"in the production program.
At least one line of data must be input for the item"ELEMENT"under"BLOCK","SOLCO". Since the name of
the block("SOLCO")and the value of the item"ELEMENT"are generally reported in supplemental data,check
there.
------------------------------
Code: 52??1174
Display: "ELEMENT"format error under"BLOCK","SOLCO".
Used by:
Cause: A format error was discovered at the reading of"ELEMENT"data
under"BLOCK","SOLCO"when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check the"ELEMENT"data settings under"BLOCK","SOLCO"of"UNIT","PROGRAM"in the
production program. Since the name of the block("SOLCO")and the value of the item"ELEMENT"are
generally reported in supplemental data,check there.
------------------------------
Code: 52??1175
Display: "GCCGSCN"not defined.
Used by:
Cause: There is no"GCCGSCN"definition in the"ELEMENT"item delcaration line under"BLOCK","SOLCO".
This was determined when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check the settings for item"ELEMENT"under"BLOCK","SOLCO"of"UNIT","PROGRAM".
The"GCCGSCN"item setting is required. Since the name of the block("SOLCO")and the value of the
item"ELEMENT"are generally reported in supplemental data,check there.
------------------------------
Code: 52??1176
Display: Missing number in"GCCGSCN"
Used by:
Cause: There is a missing number in the"GCCGSCN"item of the"ELEMENT"item
under"BLOCK","SOLCO". This was determined when"UNIT","PROGRAM"of the specified production
program was read.
Remedy: Check the"ELEMENT"item under"BLOCK","SOLCO"of"UNIT","PROGRAM". The"GCCGSCN"item
must have values set from 1 to the final number in sequential order. Since the name of the
block("SOLCO")and the value of the item"ELEMENT"are generally reported in supplemental data,check
there. Missing numbers are also reported at the default check.
------------------------------
Code: 52??1200
Display: No mark data file.
Used by:
Cause: The mark data file referred to in the specified production program was not found. This report is
made if the mark data and production program are in different files, the mark data referred to in the
production program is required in the applicable machine type and the above error is detected.
Remedy: Check the settings for "GMKFN", "GMKBN", "GMKGN", and "GMNMN" in "BLOCK", "PGHEAD-" in
the production program. Also check whether the file is in the mark data directory.
------------------------------
第 2283 页