Display: Element的引脚数比设定值要少 Used by: XP241,XP341,XP242 Cause: 引脚根数检查出错。 Remedy: 请更换发生错误的元件或确认元件数据是否正确。特别要确认元件数据的引脚数是否正确。如元件数据正确 时,请调查吸取状态是否良好、影像的明亮度是否有问题、焦距是否对准、以及是否摄有污垢。 ------------------------------ Code: 12100088 Disp…

100%1 / 5282
[Coplanarity]. (QP3)
------------------------------
Code: 121???72
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: The lead coplanarity check indicates that the number of measured leads does not match the
number of leads specified in part data.
Remedy: Check for bend leads. Verify that the measurement is not occurring too close to the lead ends.
Verify that the following part data settings are correct: Lead-Length, Lead-Width, Body-Length, Body-
Width.
The coplanarity check result can be viewed at the [Coplanarity] screen. (QP3)
However, only the most recently performed check for each holder can be viewed. (QP3)
The [Coplanarity] screen can be reached through the following path: [Main] -[Maintenance] -
[Coplanarity]. (QP3)
------------------------------
Code: 121???73
Display: Coplanarity error(NP2,QP3)
Used by: QP242,NP2,QP3
Cause: The lead coplanarity check cannot occur because the part pickup position is too close to the
leads. (Nozzle / sensor interference could occur if performed.)
Remedy: Verify that the part size and lead length are suitable for a lead coplanarity check. Verify that the
pickup position is not too close to the part corner.
------------------------------
Code: 12100081
Display: 影像处理系统出错
Used by: XP241,XP341,XP242
Cause: 影像处理系统出错。
Remedy: 是内部错误,一般不发生。如果发生的话,请获取跟踪数据,并将它送至弊社。
------------------------------
Code: 12100082
Display: 影像处理系统出错
Used by: XP241,XP341,XP242
Cause: 影像处理系统出错。
Remedy: 是内部错误,一般不发生。如果发生的话,请获取跟踪数据,并将它送至弊社。
------------------------------
Code: 12100083
Display: 不能识别引脚
Used by: XP241,XP341,XP242
Cause: 由于某种原因,不能进行粗定位。
Remedy: 请更换发生错误的元件或确认元件与元件数据是否吻合。
特别要确认要素数据和Stand Off 是否正确。
如元件数据正确时,请调查吸取状态是否良好、影像的明亮度是否有问题、焦距是否对准、以及是否摄有污垢。
------------------------------
Code: 12100084
Display: Element的引脚数比设定值要多
Used by: XP241,XP341,XP242
Cause: 引脚根数检查出错。
Remedy: 请更换发生错误的元件或确认元件数据是否正确。特别要确认元件数据的引脚数是否正确。如元件数据正确
时,请调查吸取状态是否良好、影像的明亮度是否有问题、焦距是否对准、以及是否摄有污垢。
------------------------------
Code: 12100085
第 863 页
Display: Element的引脚数比设定值要少
Used by: XP241,XP341,XP242
Cause: 引脚根数检查出错。
Remedy: 请更换发生错误的元件或确认元件数据是否正确。特别要确认元件数据的引脚数是否正确。如元件数据正确
时,请调查吸取状态是否良好、影像的明亮度是否有问题、焦距是否对准、以及是否摄有污垢。
------------------------------
Code: 12100088
Display: 浮脚测试公差出错
Used by: XP241,XP341,XP242
Cause: 浮脚测试计算的结果,以引脚平均面为基准引脚的高度超过了浮脚测试的公差值(元件数据为 Coplanarity
Tolerance )。
Remedy: 请确认在元件上是否有引脚浮起,元件数据 Coplanarity Tolerance的值是否极为小。
------------------------------
Code: 12110001
Display: Failed to create shared memory.
Used by:
Cause: Either the system resources are insufficient, the operating system is corrupted, or the operating
system installation failed.
Remedy: Reinstall the recovery media software.
Contact Fuji if this error cannot be corrected, because the hard disk could be damaged.
------------------------------
Code: 12110002
Display: Failed to start process.
Used by:
Cause: The required file is either corrupted, or missing.
Remedy: Reinstall the recovery media software.
Contact Fuji if this error cannot be corrected, because the hard disk could be damaged.
------------------------------
Code: 12110003
Display: Failed to set the axes gear ratio.
Used by:
Cause: Failed to access the servo control board, or the servo board device driver is corrupted.
Remedy: Reinstall the recovery media software.
Contact Fuji if this error cannot be corrected, because the servo control board could be damaged.
------------------------------
Code: 12110004
Display: Failed to create thread.
Used by:
Cause: Either the system resources are insufficient, the operating system is corrupted, or the operating
system installation failed.
Remedy: Reinstall the recovery media software.
Contact Fuji if this error cannot be corrected, because the hard disk could be damaged.
------------------------------
Code: 12110005
Display: Failed to create event.
Used by:
Cause: Either the system resources are insufficient, the operating system is corrupted, or the operating
system installation failed.
Remedy: Reinstall the recovery media software.
Contact Fuji if this error cannot be corrected, because the hard disk could be damaged.
------------------------------
第 864 页
Code: 12110006
Display: Failed to create semaphore.
Used by:
Cause: Either the system resources are insufficient, the operating system is corrupted, or the operating
system installation failed.
Remedy: Reinstall the recovery media software.
Contact Fuji if this error cannot be corrected, because the hard disk could be damaged.
------------------------------
Code: 12110007
Display: Event creation abnormal.
Used by:
Cause: From the RTX process, Win32 event creation was abnormal. It is possible that the system
installation failed.
Remedy: Reinstall the system.
Contact Fuji if this error is not corrected after the reinstall, because the servo controller could be
damaged.
------------------------------
Code: 12110008
Display: Semaphore creation abnormal.
Used by:
Cause: From the RTX process Win32 semaphore creation was abnormal. It is possible that the system
installation failed.
Remedy: Reinstall the system.
Contact Fuji if this error is not corrected after the reinstall, because the servo controller could be
damaged.
------------------------------
Code: 12110009
Display: Process creation abnormal.
Used by:
Cause: From the RTX process Win32 process creation was abnormal. It is possible that the system
installation failed.
Remedy: Reinstall the system.
Contact Fuji if this error is not corrected after the reinstall, because the servo controller could be
damaged.
------------------------------
Code: 1211000a
Display: Missing file.
Used by:
Cause: A file required cannot be found. The required file could either be corrupted or may have been
deleted.
Remedy: Reinstall the system. Contact Fuji if the same error occurs after the reinstallation, because the
hard disk could be damaged.
------------------------------
Code: 1211000b
Display: Synchronize object error.
Used by:
Cause: Object synchronization was not completed. The system resources are insufficient, the operating
system is corrupted, or the operating system installation failed.
Remedy: Reinstall the recovery media software.
Contact Fuji if this error cannot be corrected, because the hard disk could be damaged.
------------------------------