FUJI错误代码查询.pdf - 第560页

Cause: The lower limit detection sensor for the ST11 cylinder has not turned on. Remedy: The action of the ST11 cylinder has deteriorated.Check the cylinder as prescribed in the maintenance manual. Please note that the c…

100%1 / 5282
(X099). Adjust the sensors as necessary.
------------------------------
Code: 1205407E
Display: "Pal Transport Err RCONV->UPELV"
Used by: CP652C
Cause: The forward end check sensor for the cylinder of the pallet conveyor between the return conveyor
and the UP elevator has not turned on even though the specified time has elapsed since the cylinder was
instructed to start moving, or the pallet movement complete status was not achieved when the forward
end check sensor turned on."Pallet movement complete status" is as follows: when the return conveyor
pallet OUT cylinder forward end check sensor turns on, the return conveyor pallet OUT cylinder re ract
end check sensor should be off, the return conveyor pallet arrival check sensor should be off, the UP
elevator pallet check sensor should be on, and the UP elevator pallet passage check sensor should be on.
Remedy: Make sure that nothing is obstructing pallet movement. If there is no obstruction, perform an
I/O check on the input from the following sensors: return conveyor pallet OUT cylinder forward end check
(X09A) and retract end check (X09B), return conveyor pallet arrival check (X09E), UP elevator pallet check
(X084), and UP elevator pallet passage check (X085). Adjust the sensors as necessary.
------------------------------
Code: 1205407F
Display: "Pallet_Clamp Error DF or DR"
Used by: CP652C
Cause: The DF-axis (or DR-axis) has failed to clamp a pallet, or a clamp status check performed during
DF-axis (or DR-axis) operation has shown that a pallet is not clamped properly.
Remedy: Make sure that the DF-axis and DR-axis clamps are functioning normally. Perform I/O checks
on input from the following sensors: pallet clamp check (X058 and X05B), pallet unclamp check (X059and
X05C), and pallet check (X05A and X05D) for the DF-axis and DR-axis. Adjust the sensors as necessary.
When a pallet is clamped, the sensors for that axis should be as follows: the pallet clamp and pallet check
sensors should be on, and the pallet unclamp check sensor should be off.
------------------------------
Code: 12054080
Display: " R.Conv IN(OUT) Cylinder Time Out"
Used by: CP652C
Cause: Either the retract end check sensor for the return conveyor pallet IN or OUT cylinder has not
turned on even though the specified time has elapsed since the cylinder was instructed to start retracting,
or both the forward end and retract end check sensors have turned on.
Remedy: Make sure that nothing is obstructing cylinder operation.If there is no obstruction, perform an
I/O check on the input from the following sensors: return conveyor pallet IN and OUT cylinderforward end
check (X09A and X09C) and retract end check (X09B and X09D). Adjust the sensors as necessary.
------------------------------
Code: 12054081
Display: "Pallet_Unclamp Error DF or DR"
Used by: CP652C
Cause: The DF-axis (or DR-axis) has failed to unclamp a pallet.
Remedy: Make sure that the DF-axis and DR-axis unclamp operation is functioning normally.Perform I/O
checks on input from the following sensors: pallet clamp check (X058 and X05B), pallet unclamp check
(X059 and X05C), and pallet check (X05A and X05D) for the DF-axis and the DR-axis. Adjust the sensors
as necessary. When a pallet is unclamped, the sensors for that axis should be as follows: the pallet clamp
and pallet check sensors should be off, and the pallet unclamp check sensor should be on.
------------------------------
Code: 12054082
Display: "ST11:Nozzle up/down error.", "ST11:Check cylinder." (CP6,6M)]
Used by: CP6,CP643
第 559 页
Cause: The lower limit detection sensor for the ST11 cylinder has not turned on.
Remedy: The action of the ST11 cylinder has deteriorated.Check the cylinder as prescribed in the
maintenance manual. Please note that the component may not have been placed by ST11 (i.e., it may be
missing).
------------------------------
Code: 12054083
Display: "Air Cylinder Cycle Alarm SQG Open/Close"
Used by: GP551,GP6
Cause: Squeegee opening or closing required longer than the specified time.
Remedy: Check the squeegee open check sensor (X078:SQG OPEN CHK) and the squeegee closed check
sensor (X079:SQG CLOSE CHK).
------------------------------
Code: 12054084
Display: "Air Cylinder Cycle Alarm top Cleaner Connected"
Used by: GP551,GP6
Cause: Insertion of the notch required longer than the specified time.
Remedy: Use I/O commands to check the sensor (GSP5, GP6).
------------------------------
Code: 12054085
Display: "Air Cylinder Cycle Alarm Head Lock"
Used by: GP551
Cause: Insertion of the notch required longer than the specified time.
Remedy: Use I/O commands to check the sensor.
------------------------------
Code: 12054086
Display: "Air Cylinder Cycle Alarm Top Cleaner Lock"
Used by:
Cause: Insertion of the notch required longer than the specified time.
Remedy: Use I/O commands to check the sensor.
------------------------------
Code: 12054087
Display: "Pallet Transport ERROR UP Elevator -> SETUP_ST. IN"
Used by: CP652C
Cause: A pallet transport error occured between the up-elevator and the in-setup station. The cause of
the error may be one of the following.
1. The pallet in-cylinder has not reached its extended position in the 10 seconds allowed.
2. The input status for each of the sensors after the pallet in-cylinder arrived at its extended position is as
follows:
- The retract position sensor is on.
- The up-elevator pass-through sensor (between up-elevator <-> in-setup station) is detecting a pallet or is
being obstructed.
- The up-elevator pallet sensor is detecting a pallet.
- The setup station pallet sensor is not detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the pallet in-cylinder sensor (X088) and the retract position sensor (X089).
Check the input status of the up-elevator pallet pass-through sensor (X085).
Check the input status of the up-elevator pallet sensor (X084).
Check the input status of the in-setup station pallet sensor (X077).
------------------------------
Code: 12054088
Display: "Pallet Transport ERROR SETUP_ST. IN -> IN Pos."
第 560 页
Used by: CP652C
Cause: When the pallet is moving from the in-setup station to the in-position:
1. The in-setup station cylinder has not reached its extended position in the 10 seconds allowed.
2. The input status for each of the sensors, after the in-setup station cylinder has arrived at its extended
position, is as follows:
- The retract position (extended position) sensor is on.
- The in-setup station pallet pass-through sensor (between in-position <-> in-setup station) is detecting a
pallet.
- The in-setup station pallet sensor is detecting a pallet.
- The in-position pallet sensor is not detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X072) for the in-setup station cylinder and the
retract position sensor (X073).
Check the input status of the in-setup station pallet pass-through sensor (X06E).
Check the input status of the in-setup station pallet sensor (X077).
Check the input status of the in-position pallet sensor (X046).
------------------------------
Code: 12054089
Display: "Pallet Transport ERROR IN Pos -> SETUP_ST. IN."
Used by: CP652C
Cause: When the pallet is moving from the in-position to the in-setup station:
1. The in-setup station cylinder has not reached its retract position in the 10 seconds allowed.
2. The input status for each of the sensors, after the in-setup station cylinder has arrived at its retract
position, is as follows:
- The extended position sensor is on.
- The in-setup station pallet pass-through sensor (between in-position <-> in-setup station) is not
detecting a pallet.
- The in-setup station pallet sensor is not detecting a pallet.
- The in-position pallet sensor is detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X072) for in-setup station cylinder and the retract
position sensor (X073).
Check the input status of the in-setup station pallet pass-through sensor (X06E).
Check the input status of the in-setup station pallet sensor (X077).
Check the input status of the in-position pallet sensor (X046).
------------------------------
Code: 1205408A
Display: "Pallet Transport ERROR SETUP_ST. OUT -> OUT Pos."
Used by: CP652C
Cause: A pallet transport error occured between the out-setup station and the out-position.
When the pallet is moving from the out-setup station to the out-position:
1. The out-setup station cylinder has not reached its extended position in the 10 seconds allowed.
2. The input status for each of the sensors, after the out-setup station cylinder has arrived at its extended
position, is as follows:
- The retract position sensor is on.
- The out-setup station pallet pass-through sensor (between out-position <-> out-setup station) is
detecting a pallet.
- The out-setup station pallet sensor is detecting a pallet.
- The out-position pallet sensor is not detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X07A) for the out-setup station cylinder and the
第 561 页