FUJI错误代码查询.pdf - 第1095页
Used by: CP5,CP6,CP6M,CP65,GSP5,GP2,GP3,GP551,GP6,IP3 Cause: The time required to transport the board between each conveyor exceeded the preset limit. The appropriate removal setting between conveyors is made (1:ON 2:OFF…
load the board. If there was no board, the machine attempted to clear off the board.
The out-conveyor cannot convey boards due to poor board positioning.
The status of boards in the out-conveyor cannot be checked.
Remedy: Use the correct command based on conditions. Check that the command you are using can be
carried out under current conditions. Also, check the conveyor board arrival confirmation sensor at the
I/O dsiplay.
Set boards in the correct positions.
Make sure the out-conveyor board sensors (the I/O input signals listed below) correctly detect the
presence of boards in the conveyor. The board gap sensor should be ON when there is no board,and OFF
when a board is present.
I/O input signals(CP643):
LX00C: OUT1/OUT2 board gap sensor
LX00D: OUT-conveyor board arrival sensor
LX00E: OUT1 board arrival sensor
LX00F: OUT2 board arrival sensor
------------------------------
Code: 15010604
Display: Conv. PLC Alarm: OUT
Board check error:O_LIFT
Out-lif brd conf sensor on Adj sensor so it turns off
Used by: CP5,CP643,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The CPU module (board loader PLC) is not operating normally. The user cannot set this.
The out-lifter board sensors are abnormal. ( For example,a sensor is ON even though it should be OFF.
Remedy: Contact Fuji.
Make sure the out-conveyor board sensors (the I/O input signals listed
below) tuen ON and OFF correctly. The board gap sensor should be ON when there is no board,and OFF
when a board is present.
I/O input signals(CP643):
LX00C: OUT1/OUT2 board gap sensor
LX00E: OUT1 board arrival sensor
LX00F: OUT2 board arrival sensor
------------------------------
Code: 15010605
Display: Cylinder cycle alarm:O_LIFT
Up/down movement of the O_LIFT time up
Used by: CP643
Cause: The out-lifter was raised,but the upper limit sensor did not turn ON within the specified time.
The out-lifter was lowered,but the lower limit sensor did not turn ON within the specified time.
The out-lifter upper and lower limit sensors are both ON.
Remedy: Make sure the out-lifter operates smoothly.
Make sure the upper and lower limit sensors have been attached at the correct positions.
Make sure the upper and lower limit sensors (the I/O input signals listed below) turn ON and OFF.
Make sure the upper and lower limit sensors (the I/O input signals listed below) turn ON and OFF
correctly when the out-lifter is raised and lowered.
I/O input signals:
LX03E: OUT-lifter upper limit sensor
LX03F: OUT-lifter lower limit sensor
------------------------------
Code: 15010701
Display: PCB Transport Error: NEXT
Chk conveyance to next machine
第 1094 页
Used by: CP5,CP6,CP6M,CP65,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The time required to transport the board between each conveyor exceeded the preset limit. The
appropriate removal setting between conveyors is made (1:ON 2:OFF 3:OFF).
Remedy: Check that there is no board stuck between this point and the previous production stage.
------------------------------
Code: 15010702
Display: PCB Stopper Error: NEXT
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: Stopper alarm. (1:OFF 2:ON 3:OFF) The stopper between each conveyor produced a cycle alarm.
This occurs when the time setting between the leading edge and the leaving edge is not on. After the
stopper moves vertically, the stopper vertical movement check sensor does not activate within 5 seconds to
check the position of the board stopper.
Remedy: Check for obstacles hindering stopper movement. If these obstacles (such as a board) exist,
remove them. If there are no obstacles, check the movement of the stopper at the I/O display, and check
the cancel stopper sensor.
------------------------------
Code: 15010703
Display: Command Error: NEXT
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The operator has attempted to unload or change boards when there is no board. The operator
has attempted to load a board when there is already a board. If there was a board on the conveyor the
machine attempted to load the board. If there was no board, the machine attempted to clear off the board.
Remedy: Use the correct command based on conditions. Check that the command you are using can be
carried out under current conditions. Also, check the conveyor board arrival confirmation sensor at the
I/O dsiplay.
------------------------------
Code: 15010704
Display: Conv. PLC Alarm: NEXT
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The CPU module (board loader PLC) is not operating normally. The user cannot set this.
Remedy: Contact Fuji.
------------------------------
Code: 15010801
Display: PCB Transport Error: UD.CONV
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The time required to transport the board between the two step conveyor exceeded the preset limit.
The appropriate removal setting is made (1:ON 2:OFF 3:OFF).
Remedy: Check that there is no board stuck between this point and the previous production stage.
------------------------------
Code: 15010802
Display: PCB Stopper Error: UD.CONV
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: Stopper alarm. (1:OFF 2:ON 3:OFF) The stopper between each conveyor produced a cycle alarm.
This occurs when the time setting between the leading edge and the leaving edge is not on. After the
stopper moves vertically, the stopper vertical movement check sensor does not activate within 5 seconds to
check the position of the board stopper.
Remedy: Check for obstacles hindering stopper movement. If these obstacles (such as a board) exist,
remove them. If there are no obstacles, check the movement of the stopper at the I/O display, and check
the cancel stopper sensor.
------------------------------
Code: 15010803
第 1095 页
Display: Command Error: UD.CONV
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The operator has attempted to unload or change boards when there is no board. The operator
has attempted to load a board when there is already a board. If there was a board on the conveyor the
machine attempted to load the board. If there was no board, the machine attempted to clear off the board.
Remedy: Use the correct command based on conditions. Check that the command you are using can be
carried out under current conditions. Also, check the conveyor board arrival confirmation sensor at the
I/O dsiplay.
------------------------------
Code: 15010804
Display: Conv. PLC Alarm: UD.CONV
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The CPU module (board loader PLC) is not operating normally. The user cannot set this.
Remedy: Contact Fuji.
------------------------------
Code: 15010901
Display: PCB Transport Error: PUSHER
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The time required to transport the board through the out conveyor exceeded the preset limit. The
appropriate removal setting between conveyors is made (1:ON 2:OFF 3:OFF).
Remedy: Check that there is no board stuck between this point and the previous production stage.
------------------------------
Code: 15010902
Display: PCB Stopper Error: PUSHER
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: Stopper alarm. (1:OFF 2:ON 3:OFF) The stopper between each conveyor produced a cycle alarm.
This occurs when the time setting between the leading edge and the leaving edge is not on. After the
stopper moves vertically, the stopper vertical movement check sensor does not activate within 5 seconds to
check the position of the board stopper.
Remedy: Check for obstacles hindering stopper movement. If these obstacles (such as a board) exist,
remove them. If there are no obstacles, check the movement of the stopper at the I/O display, and check
the cancel stopper sensor.
------------------------------
Code: 15010903
Display: Command Error: PUSHER
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The operator has attempted to unload or change boards when there is no board. The operator
has attempted to load a board when there is already a board. If there was a board on the conveyor the
machine attempted to load the board. If there was no board, the machine attempted to clear off the board.
Remedy: Use the correct command based on conditions. Check that the command you are using can be
carried out under current conditions. Also, check the conveyor board arrival confirmation sensor at the
I/O dsiplay.
------------------------------
Code: 15010904
Display: Conv. PLC Alarm: PUSHER
Used by: CP5,GSP5,GP2,GP3,GP551,GP6,IP3
Cause: The CPU module (board loader PLC) is not operating normally. The user cannot set this.
Remedy: Contact Fuji.
------------------------------
Code: 15010A01
Display: Loader Type Error
第 1096 页