FUJI错误代码查询.pdf - 第684页

Cause: Servo amp error. Remedy: Reset the servo amp. ------------------------------ Code: 1206859B Display: TY-axis: Torque command A/D error! Used by: QP3,NP2 Cause: Servo amp error. Remedy: Reset the servo amp. -------…

100%1 / 5282
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 12068593
Display: TY-axis: Heat sink overheating error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 12068594
Display: TY-axis: Absolute encoder backup error!
Used by: QP3,NP2
Cause:
Remedy: It is necessary to set up the absolute encoder.After the setup is complete, remeasure the
calibration data.
------------------------------
Code: 12068595
Display: TY-axis: Absolute encoder checksum error!
Used by: QP3,NP2
Cause:
Remedy: It is necessary to set up the absolute encoder.After the setup is complete, remeasure the
calibration data.
------------------------------
Code: 12068596
Display: TY-axis: Absolute encoder battery error!
Used by: QP3,NP2
Cause:
Remedy: With the servo amplifier power on, check the battery connection.
------------------------------
Code: 12068597
Display: TY-axis: Absolute encoder data error!
Used by: QP3,NP2
Cause:
Remedy: Without removing the absolute encoder cable, check the cabling surrounding the encoder, and
fix if necessary.
------------------------------
Code: 12068598
Display: TY-axis: Absolute encoder excess speed error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 12068599
Display: TY-axis: Encoder overheating error!
Used by: QP3,NP2
Cause:
Remedy: The operating environment for the servo motor should be less than 40q-.
------------------------------
Code: 1206859A
Display: TY-axis: Travel speed instruction A/D error!
Used by: QP3,NP2
第 683 页
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 1206859B
Display: TY-axis: Torque command A/D error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 1206859C
Display: TY-axis: Gate array (JL-0409) error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 1206859D
Display: TY-axis: System error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 1206859E
Display: TY-axis: Servo error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 1206859F
Display: TY-axis: Fully closed loop phase A/B disconnected.
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 120685A0
Display: TY-axis: Fully closed loop phase C disconnected.
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 120685A1
Display: TY-axis: Absolute encoder clear and multiturn limit setting error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 120685A2
Display: TY-axis: Encoder communication error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
第 684 页
Code: 120685A3
Display: TY-axis: Encoder parameter error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 120685A4
Display: TY-axis: Encoder echo-back error.
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 120685A5
Display: TY-axis: Multiturn limit disagreement.
Used by: QP3,NP2
Cause:
Remedy: Check that the correct value is entered for the Pn205 servo parameter.
------------------------------
Code: 120685A6
Display: TY-axis: Position deviation overflow error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 120685A7
Display: TY-axis: No option error!
Used by: QP3,NP2
Cause:
Remedy: Check that the MECHATROLINK interface unit is correctly attached to the servo amplifier.If
correct installation does not rectify the problem, replace the MECHATROLINK interface unit.
------------------------------
Code: 120685A8
Display: TY-axis: Option time-out error!
Used by: QP3,NP2
Cause:
Remedy: Check that the MECHATROLINK interface unit is correctly attached to the servo amplifier.If
correct installation does not rectify the problem, replace the MECHATROLINK interface unit.
------------------------------
Code: 120685A9
Display: TY-axis: Option WDC error!
Used by: QP3,NP2
Cause:
Remedy: Check that the MECHATROLINK interface unit is correctly attached to the servo amplifier.If
correct installation does not rectify the problem, replace the MECHATROLINK interface unit.
------------------------------
Code: 120685AA
Display: TY-axis: WDT error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
第 685 页