FUJI错误代码查询.pdf - 第563页
Code: 1205408E Display: "SETUP_ST. IN Feeder Time Out" Used by: CP652C Cause: The cylinder used to clamp the pallet, when clamping is attempted by the in-setup station cylinder, has not reached the clamp positi…
retract position sensor (X07B).
Check the input status of the out-setup station pallet pass-through sensor (X06F).
Check the input status of the out-setup station pallet sensor (X07F).
Check the input status of the out-position pallet sensor (X047).
------------------------------
Code: 1205408B
Display: "Pallet Transport ERROR OUT Pos. -> SETUP_ST. OUT"
Used by: CP652C
Cause: A pallet transport error occured between the out-setup station and the out-position.
When the pallet is moving from the out-position to the out-setup station:
1. The out-setup station cylinder has not reached its retract position in the 10 seconds allowed.
2. The input status for each of the sensors, after the out-setup station cylinder has arrived at its retract
position, is as follows:
- The extended position sensor is on.
- The out-setup station pallet pass-through sensor (between out-position <-> out-setup station) is not
detecting a pallet.
- The out-setup station pallet sensor is not detecting a pallet.
- The out-position pallet sensor is detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X07A) for the out-setup station cylinder and the
retract position sensor (X07B).
Check the input status of the out-setup station pallet pass-through sensor (X06F).
Check the input status of the out-setup station pallet sensor (X07F).
Check the input status of the out-position pallet sensor (X047).
------------------------------
Code: 1205408C
Display: "Pallet Transport ERROR R. Conveyor -> Filler"
Used by: CP652C
Cause: A pallet transport error occurs when the PPS filler is operating.
1. The return-conveyor out cylinder has not reached it extended position in the 10 seconds allowed.
2. The input status for each of the sensors, after the return-conveyor out cylinder has reached its
extended position, is as follows:
- The cylinder retract position sensor is on.
- The filler pallet sensor is not detecting a pallet.
- The return-conveyor pallet arrival sensor is detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X09A) for the return-conveyor out cylinder and
the retract position sensor (X09B).
Check the input status of the filler pallet sensor (X094).
Check the input status of the return-conveyor pallet arrival sensor (X09E).
------------------------------
Code: 1205408D
Display: "Pallet Transport ERROR Filler -> PPS"
Used by: CP652C
Cause: A pallet transport error occurred between the filler and the PPS6.
1. After the PPS6 has pulled the pallet in (after the cylinder on the lower conveyor has reached its
extended position), the filler pallet sensor is still detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the PPS6 lower conveyor cylinder's extended position and retract position.
Check the input status of the filler pallet sensor (X094).
------------------------------
第 562 页
Code: 1205408E
Display: "SETUP_ST. IN Feeder Time Out"
Used by: CP652C
Cause: The cylinder used to clamp the pallet, when clamping is attempted by the in-setup station
cylinder, has not reached the clamp position in the 10 seconds allowed.
Remedy: Check that there is nothing obstructing the movement of the in-setup station cylinder.
Check the input status of the extended (X072) and retract (X073) position for the in-setup station cylinder.
------------------------------
Code: 1205408F
Display: "SETUP_ST. IN Slide Time Out"
Used by: CP652C
Cause: Operation of the in-setup station slide has not been completed in the 10 seconds allowed.
Remedy: Check that there is nothing obstructing the movement of the in-setup station slide.
Check the input status of the extended (X070) and retract (X071) position for the in-setup station slide.
------------------------------
Code: 12054090
Display: "SETUP_ST. OUT Feeder Time Out"
Used by: CP652C
Cause: The cylinder used to clamp the pallet, when clamping is attempted by the out-setup station
cylinder, has not reached the clamp position in the 10 seconds allowed.
Remedy: Check that there is nothing obstructing the movement of the out-setup station cylinder.
Check the input status of the extended (X07A) and retract (X07B) position for the out-setup station
cylinder.
------------------------------
Code: 12054091
Display: "SETUP_ST. OUT Slide Time Out"
Used by: CP652C
Cause: Operation of the out-setup station slide has not been completed in the 10 seconds allowed.
Remedy: Check that there is nothing obstructing the movement of the out-setup station slide.
Check the input status of the extended (X078) and retract (X079) position for the out-setup station slide.
------------------------------
Code: 12054092
Display: "SETUP_ST. IN Interlock on"
Used by: CP652C
Cause: The pallet pass-through sensor between the in-setup station and in-position is detecting a pallet
as the in-setup station slide attempts to move.
Remedy: Remove the obstruction.
Check the pallet pass-through sensor (X06E).
------------------------------
Code: 12054093
Display: "SETUP_ST. OUT Interlock on"
Used by: CP652C
Cause: The pallet pass-through sensor between the out-setup station and out-position is decting a pallet
as the out-setup station slide attempts to move.
Remedy: Remove the obstruction.
Check the pallet pass-through sensor (X06F).
------------------------------
Code: 12054094
Display: "SETUP_ST. IN Origin Position Error"
Used by: CP652C
Cause: The slide is off-center of the extended position when the pallet attempts to move between the in-
第 563 页
setup station and the in-position.
Remedy: Check the slide's extended position.
Check the I/O signal X070 when the slide is at its extended position.
------------------------------
Code: 12054095
Display: "SETUP_ST. OUT Origin Position Error"
Used by: CP652C
Cause: The slide is off-center of the extended position when the pallet attempts to move between the out-
setup position and the out-position.
Remedy: Check the slide's extended position.
Check the I/O signal X078 when the slide is at its extended position.
------------------------------
Code: 12054096
Display: "Pallet Clamp Err SET_ST. IN(OUT)"
Used by: CP652C
Cause: Before operation is started:
- The setup station's (in/out) pallet clamp is not engaged properly or, the state in which it is disengaged is
abnormal.
- There is a pallet at the setup station (in/out) as well as the pallet's ID information data but the pallet is
not clamped.
During operation:
- The pallet that arrived at the setup station (in/out) can not be clamped properly when the attempt is
made.
Remedy: Check that the pallet is clamped properly at the setup station (in/out).
Check the input status for each of the clamping pin sensors.
Pallet clamp sensor (setup station IN:X074, OUT:X07C), pallet unclamp sensor (setup station IN:X075,
OUT:X07D), pallet sensor (setup station IN:X076, OUT:X07E).
Check that the D-axis pallet ID data matches that of the current pallet position using the command
sequence [SET] -> [POSITION] -> [SET PALLET] -> [DEFINE].
Clamp state:
- Pallet clamp sensor (IN:X074) (OUT:X07C): on
- Unclamp sensor (IN:X075) (OUT:X07D): off
- Pallet sensor (IN:X076) (OUT:X07E): on
Unclamp state:
- Pallet clamp sensor (IN:X074) (OUT:X07C): off
- Unclamp sensor (IN:X075) (OUT:X07D): on
- Pallet sensor (IN:X076) (OUT:X07E): on
Irregular state:
Anything outside the above settings.
------------------------------
Code: 12054097
Display: "Pallet Unclamp Err SET_ST. IN(OUT)"
Used by: CP652C
Cause: The pallet clamp attempted to disengage when the pallet moved from the setup station (in/out),
but has not disengaged properly.
Remedy: Check the input status for each of the setup stations' clamp pin sensors.
Pallet clamp sensor (setup station IN:X074, OUT:X07C), pallet unclamp sensor (setup station IN:X075,
OUT:X07D), pallet sensor (setup station IN:X076, OUT:X07E).
Clamp state:
- Pallet clamp sensor (IN:X074) (OUT:X07C): on
- Unclamp sensor (IN:X075) (OUT:X07D): off
第 564 页