FUJI错误代码查询.pdf - 第132页
Cause: Device positions D51 and D52 cannot be used due to the camera type set in Proper data. Remedy: Move the devices at device positions D51 and D52 to alternative positions. ------------------------------ Code: 1101E2…
Used by: NXTP
Cause: 发生了关于焊锡供应设定的矛盾,成为不能供应焊锡状态。
请确认创建的生产程序是否符合以下条件。
Remedy: 请调整焊锡供应行程、焊锡供应速度、吸嘴残留焊锡调整定时器、供应结束位置焊锡量调整定时器的4个参
数并满足以下条件。
供应行程/供应速度 > 吸嘴残留焊锡调整定时器 + 供应结束位置焊锡量调整定时器
------------------------------
Code: 1101E055
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1101E056
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1101E1??
Display: NAT data error.
Used by: QP132
Cause: NAT data has not been set or, despite being part of the same family, the NAT structure is
different.
The first "?" of the "??" represents the head number ("0" is head 16). The following "?" represents the item
(1: Nozzle diameter. 2: Backlight diameter. 3: Nozzle type).
Remedy: Set the correct values in NAT data.
------------------------------
Code: 1101E200
Display: 1101E200
Used by: IP3
Cause: A positive value was entered for part data item "Fst_pickup_pnt_x" or "Tray_pickup_pnt_x".
Remedy: The X or Y-axis may interfere with the tray. Input a negative value for part data item
"Fst_pickup_pnt_x" or "Tray_pickup_pnt_x".
------------------------------
Code: 1101E201
Display: 1101E201
Used by: IP3
Cause: A negative value was entered for part data item "Fst_pickup_pnt_y" or "Tray_pickup_pnt_y".
Remedy: The X or Y-axis may interfere with the tray. Input a positive value for part data item
"Fst_pickup_pnt_y" or "Tray_pickup_pnt_y".
------------------------------
Code: 1101E202
Display: Same as code
Used by: IP3
Cause: Device positions D36 and D37 cannot be used due to the camera type set in Proper data.
Remedy: Move the devices at device positions D36 and D37 to alternative positions.
------------------------------
Code: 1101E203
Display: Same as code
Used by: IP3
第 131 页
Cause: Device positions D51 and D52 cannot be used due to the camera type set in Proper data.
Remedy: Move the devices at device positions D51 and D52 to alternative positions.
------------------------------
Code: 1101E204
Display: Same as code
Used by: GP551, GP641
Cause: The pressure applied to the pusher during printing is outside
the permissible range.
Remedy: Ensure that a value within the range 0.5 to 5.0 [kgf/cm2] is specified at the production program
item "Pusher Pressure During Print"
or at the sequence data item "Print Pusher Seq (F4G) MM (MCS)".
If "0" is specified at the above sequence data item, the "Pusher Pressure During Print" item is referenced.
GP-551E version V1.12, or GP-641E version V1.23 are required to support sequential pusher pressure
settings.
------------------------------
Code: 1101E205
Display: Same as code
Used by: GP551, GP641
Cause: The pressure applied to the pusher during solder supply is outside the permissible range.
Remedy: Ensure that the production program item "Pusher Pressure After Refill" is within the range of 0.5
to 5.0 kgf/cm2.
------------------------------
Code: 1101E206
Display: Same as code
Used by: QP242
Cause: The selected nozzle station is not fitted on the machine.
Remedy: The selected nozzle station is not fitted on the machine. The setting for "Nozzle Station ID" in
the production program is different in Proper data.
------------------------------
Code: 1101E207
Display: Same as code
Used by: CP643,CP7series,QPseries,NPseries,GL541
Cause: The Pcb_position_tolerance item in the production program is set to a value greater than mark
data scan value.
Remedy: Set Pcb_position_tolerance to a value less than the Scan value in mark data.
------------------------------
Code: 1101E208
Display: Same as code
Used by: QP242
Cause: Fiducial mark data not found in header data.
Remedy: Enter fiducial mark data in the program header.
------------------------------
Code: 1101E300
Display: 没有设定基准定位点。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 没有设定生产程序的基准定位点。
Remedy: [机上编辑] 请在定位点编辑画面上设定基准定位点。
[Fuji Flexa] 请设定基准定位点。
------------------------------
Code: 1101E301
Display: 没有设定子电路板跳过定位点。
第 132 页
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 虽然存在子电路板跳过定位点引脚顺序,但没有设定子电路板跳过定位点数据。
Remedy: [机上编辑] 请在定位点编辑画面上设定子电路板跳过定位点数据。
[Fuji Flexa] 请设定子电路板跳过定位点数据。
------------------------------
Code: 1101E400
Display: 没有对应Program Polarity的No。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: XP系列没有对应Program Polarity的No。(从MCS/2接收时例外。)
Remedy: 请将Program Polarity设定为Yes。
------------------------------
Code: 1101E401
Display: 在XP-1系列上没有对应于从MCS/2处所接收的程序的Program Polarity的No。
Used by: XP241,XP341,XP242
Cause: 在XP-1系列上从MCS/2接收的程序中设定Program Polarity的No时,不可以在XP-1系列以外的地方使用。
Remedy: 请将Program Polarity设定为Yes。
------------------------------
Code: 1101E402
Display: 在XP-2系列或者XP-3系列上没有对应于从MCS/2处所接收的程序的Program Polarity的No。
Used by: XP141,XP142
Cause: 在XP-2系列或XP-3系列上从MCS/2接收的程序中设定Program Polarity的No时,不可以在XP-2系列或XP-
3系列以外的地方使用。
Remedy: 请将Program Polarity设定为Yes。
------------------------------
Code: 1101E403
Display: 保存Job时,请将修正值X、Y设定为0.00。
Used by: XP142,XP242
Cause: 保存Job时,请将修正值X、Y设定为0.00。
Remedy: 请将修正值X、Y设定为0.00。
有必要修正时,请在[顺序]-[坐标修正量]上将作为对象的所有的接口No和顺序种类的坐标移开。
或者,请保存生产程序(Recipe)。
------------------------------
Code: 1101E404
Display: 使用料盘时,不能生产电路板尺寸Y超过200.00[mm]的电路板。
Used by: XP142
Cause: 使用料盘时,不能生产电路板尺寸Y超过200.00[mm]的电路板。
Remedy: 请确认电路板尺寸Y是否正确。
------------------------------
Code: 1101E405
Display: 电路板切口部分太宽。
Used by: XP143,XP243
Cause: 电路板切口部分太宽。
电路板切口长度XL、电路板切口长度XR只能为设定在电路板尺寸X的一半以下的数值。
电路板尺寸X - (电路板切口长度XL + 电路板切口长度XR)必须在 20.00 以上。
Remedy: 请确认电路板切口长度XL、电路板切口长度XR的设定。
------------------------------
Code: 1101E406
Display: 贴装基准面不在合适的范围内。
Used by: XP142,XP242,XP143,XP243
Cause: 使用搬运托架时,(电路板的厚度 - 搬运托架的厚度)必须在-0.50以上。
Remedy: 请确认电路板的厚度和搬运托架的厚度。
第 133 页