FUJI错误代码查询.pdf - 第591页
Remedy: Raise the main stopper. Alternatively, check the on/off status of the main conveyor stopper's engaged/disengaged sensors. <img src="$LKEY_ERRIMG_MC$/1205612D.PNG"> ---------------------------…
Display: Interlock Top cleaner Supply Solder
Used by: GP551
Cause: The solder supply unit (SSD-axis) and the upper cleaner may collide. This error occurs when the
solder supply unit (SSD-axis) is not at the retract position and the cleaner axis is moving.
Remedy: Move the solder supply unit (SSD-axis) to the retract position. Alternatively, check the on/off
status of the SSD-axis' retract position sensor.
------------------------------
Code: 12056128
Display: 联锁 相机 下清洁器连结
[Interlock Camera ]
Used by: GP551,GPX
Cause: CX轴与下清洁器连结着。在CY轴移动时CX轴与下清洁器处于连结状态的情况下发生。 存在清洁器和相
机机械手发生了干涉的可能性。 (GPX)
Remedy: 请解除CX轴与下清洁器的连结。或者,请确认下清洁器连结、下清洁器/相机轴接近的各确认传感器的
ON/OFF动作。 1.请用手将清洁器移动到退避位置。
2.发生了干涉时,请与本公司的Support联系。(GPX)
<img src="$LKEY_ERRIMG_MC$/EI0021.bmp">
------------------------------
Code: 12056129
Display: Interlock S axis Solder Pusher
Used by: GP551
Cause: This error occurs when the S-axis moves while the solder pusher is down.
Remedy: Raise the solder pusher. Alternatively, check the on/off status of the solder pusher's up
position/down position sensors.
------------------------------
Code: 1205612A
Display: Interlock S axis SQG Open/Close
Used by: GP551
Cause: This error occurs when the S-axis moves while the squeegee head is opened.
Remedy: Close the squeegee head. Alternatively, check the on/off status of the squeegee head's
open/closed sensors.
------------------------------
Code: 1205612B
Display: "Interlock S axis"
Used by: GP551
Cause: This error occurs if the S-axis is moved while the squeegee head is not stored.
Remedy: Store the squeegee head. If necessary, make sure that the squeegee head storage check sensor
is functioning normally.
------------------------------
Code: 1205612C
Display: Interlock Y axis Z axis
Used by: GP551
Cause: This error occurs if the Y-axis moves when the Z-axis is not at the retract position.In order to
detect an abnormal board width, the Y-axis can only move when the Z-axis is at the retract position.
Remedy: Move the Z-axis to the retract position. Alternatively, check the on/off status of the Z-axis'
retract position sensor.
------------------------------
Code: 1205612D
Display: Interlock Y axis Main Stopper
Used by: GP551,NXTP
Cause: This error occurs when the Y-axis moves while the main stopper is down.
第 590 页
Remedy: Raise the main stopper. Alternatively, check the on/off status of the main conveyor stopper's
engaged/disengaged sensors.
<img src="$LKEY_ERRIMG_MC$/1205612D.PNG">
------------------------------
Code: 1205612E
Display: Interlock Y axis Push Plate
Used by: GP551
Cause: The push plate is down. This error occurs if the Y-axis moves when the push plate is down.
Remedy: Raise the push plate.Alternatively, check the on/off status of the push plate's raised
position/lowered position sensors.
------------------------------
Code: 1205612F
Display: Interlock Y axis/Frame
Used by: GP551
Cause: To prevent the side clamp from colliding with the frame, the Y-axis cannot be moved.
Remedy: Lower the Z-axis until the lower limit sensor comes on. Alternatively, check the on/off status of
the sensor. (X034Y AXIS ILK)
------------------------------
Code: 12056130
Display: InterlockComp axis/Screen Clamp
Used by: GP551
Cause: This error occurs when the compensation axis moves while the upper clamp is engaged.
Remedy: Unclamp the screen. Alternatively, check the on/off status of the screen's upper clamp
clamped/unclamped sensor.
------------------------------
Code: 12056131
Display: "Interlock Supply Solder S axis"
Used by: GP551
Cause: The S-axis may interfere with the solder supply unit (SSD-axis). This error occurs if the solder
supply unit (SSD-axis) is moved while the S-axis is not at the escape position.
Remedy: Move the S-axis to the escape position. If necessary, make sure that the S-axis escape position
check sensor is functioning normally.
------------------------------
Code: 12056132
Display: Interlock Supply Solder Top Cleaner
Used by: GP551
Cause: The top cleaner and the solder supply unit (SSD-axis) may collide. This error occurs if the solder
supply unit moves when the top cleaner is not at its origin position.
Remedy: Move the top cleaner to its origin position. Alternatively, check the on/off status of the top
cleaner's origin position sensor.
------------------------------
Code: 12056133
Display: 联锁 Z轴 下清洁器及相机
Used by: GP551,GPX
Cause: Z轴与下清洁器及相机(CX轴)发生了干涉。或者,有可能发生干涉。在Z轴启动时下清洁器在原位置及
相机(CX轴)不在待机位置的情况下发生。
Remedy: 请将下清洁器移动到原位置,将相机(CX轴)移动到待机位置。或者,请确认下清洁器原位置确认传感器
、CX轴相机待机确认传感器的ON/OFF动作。
------------------------------
Code: 12056134
Display: Interlock Y-axis Camera
第 591 页
Used by: GP551
Cause: The machine attempted to move the Y-axis but was not able to because the Z-axis is in a position
(or may be in a position) where it is interfering with the camera (CX-axis).
Remedy: Move the Z-axis to a position where it does not interfere with the camera (CX-axis) or move the
camera (CX-axis) to its retract position.If this does not solve the problem, try checking whether the sensor
at the camera (CX-axis) retract position turns on and off correctly.
------------------------------
Code: 12056135
Display: Interlock Y-axis Lower cleaner
Used by: GP551
Cause: The machine attempted to move the Y-axis but was not able to because the Z-axis is in a position
(or may be in a position) where it is interfering with the lower cleaner.
Remedy: Move the Z-axis to a position where it does not interfere with the lower cleaner or move the lower
cleaner to its origin position. If this does not solve the problem, try checking whether the sensor at the
lower cleaner origin position turns on and off correctly.
------------------------------
Code: 12056136
Display: Interlock Y-axis Lower cleaner/camera
Used by: GP551
Cause: The machine attempted to move the Y-axis but was not able to because the Z-axis is in a position
(or may be in a position) where it is interfering with the lower cleaner and the camera (CX-axis). This
occurs if the lower cleaner is not at its origin or the camera (CX-axis) is not at its retract position when the
Z-axis attempts to move.
Remedy: Move the lower cleaner to its origin and the camera (CX-axis) to its retract position. If this does
not solve the problem, try checking whether the sensors at the lower cleaner origin position and the
camera (CX-axis) retract position turn on and off correctly.
------------------------------
Code: 12056137
Display: Change Station Door Open
Used by: QP132
Cause: The change station door sensor (X02A:CHGST DOOR OK) is not on when zero setting is
performed.
Remedy: Close and lock the door using the key.
------------------------------
Code: 12056138
Display: 维修保养钥匙错误
Used by: PCC
Cause: 维修保养钥匙处于ON,不能够自动运转。
Remedy: 请将维修保养钥匙设置为OFF。
------------------------------
Code: 12056139
Display: Parts pick-up error!
Used by: QP301
Cause: A part was still held by the FOL carrier during unloading.
Remedy: Check for remaining parts on the FOL carrier and check the action of the parts recognition
sensors.
------------------------------
Code: 1205613A
Display: Missing package error!
Used by: QP301
Cause: An empty pocket has been detected.
第 592 页