FUJI错误代码查询.pdf - 第41页
Remedy: Check the holder numbers at sequences 0751~0875. When the same head tries to take 2 nozzle sizes, there is interference and this error occurs (IP2). ------------------------------ Code: 11011627 Display: Used by:…
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0000~0125).
Remedy: Check the holder numbers at sequences 0000~0125. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011621
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0126~0250).
Remedy: Check the holder numbers at sequences 0126~0250. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011622
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0251~0375).
Remedy: Check the holder numbers at sequences 0251~0375. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011623
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0376~0500).
Remedy: Check the holder numbers at sequences 0376~0500. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011624
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0501~0625).
Remedy: Check the holder numbers at sequences 0501~0625. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011625
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0626~0750).
Remedy: Check the holder numbers at sequences 0626~0750. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011626
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0751~0875).
第 40 页
Remedy: Check the holder numbers at sequences 0751~0875. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011627
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 0876~1000).
Remedy: Check the holder numbers at sequences 0876~1000. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011628
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 1001~1125).
Remedy: Check the holder numbers at sequences 1001~1125. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011629
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 1126~1250).
Remedy: Check the holder numbers at sequences 1126~1250. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 1101162A
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 1251~1375).
Remedy: Check the holder numbers at sequences 1251~1375. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 1101162B
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 1376~1500).
Remedy: Check the holder numbers at sequences 1376~1500. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 1101162C
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 1501~1625).
Remedy: Check the holder numbers at sequences 1501~1625. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
第 41 页
Code: 1101162D
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 1626~1750).
Remedy: Check the holder numbers at sequences 1626~1750. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 1101162E
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 1751~1875).
Remedy: Check the holder numbers at sequences 1751~1875. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 1101162F
Display:
Used by: IP2
Cause: A nozzle which cannot be used is set for use at holder 2 or 3
(sequences 1876~2000).
Remedy: Check the holder numbers at sequences 1876~2000. When the same head tries to take 2 nozzle
sizes, there is interference and this error occurs (IP2).
------------------------------
Code: 11011630
Display:
Used by: IP2
Cause: The device number and holder number contradict each other
(sequences 0001~0125).
Remedy: Check sequences 0001~0125. Holder 2 on head 1 (nozzle 2), and holder 1 on head 2 (nozzle 3)
each have device numbers from which they cannot pick. If one of these holders has one of these out of
range device numbers assigned, this error occurs (IP2).
------------------------------
Code: 11011631
Display:
Used by: IP2
Cause: The device number and holder number contradict each other
(sequences 0126~0250).
Remedy: Check sequences 0126~0250. Holder 2 on head 1 (nozzle 2), and holder 1 on head 2 (nozzle 3)
each have device numbers from which they cannot pick. If one of these holders has one of these out of
range device numbers assigned, this error occurs (IP2).
------------------------------
Code: 11011632
Display:
Used by: IP2
Cause: The device number and holder number contradict each other
(sequences 0251~0375).
Remedy: Check sequences 0251~0375. Holder 2 on head 1 (nozzle 2), and holder 1 on head 2 (nozzle 3)
each have device numbers from which they cannot pick. If one of these holders has one of these out of
range device numbers assigned, this error occurs (IP2).
------------------------------
第 42 页