FUJI错误代码查询.pdf - 第1444页
Remedy: Check Part data. ------------------------------ Code: 1D140002 Display: Used by: Cause: The part cannot be picked. Remedy: Replenish the part supply. ------------------------------ Code: 1D144001 Display: Used by…
Code: 1D13C4??
Display:
Used by:
Cause: An edge could not be detected on the left side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D13C5??
Display:
Used by:
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D13C6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D13C7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D13D000
Display:
Used by:
Cause: The part pickup slippage was too large (X direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D13D080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D13E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D13F???
Display:
Used by:
Cause: There was a logical error in the management program.
第 1443 页
Remedy: Check Part data.
------------------------------
Code: 1D140002
Display:
Used by:
Cause: The part cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D144001
Display:
Used by:
Cause: This Vision number is unsupported.
Remedy: It is necessary to upgrade the software.
------------------------------
Code: 1D144007
Display:
Used by:
Cause: There are 2~4 leads more than set in Part data.
Remedy: Check the setting in Part data.
------------------------------
Code: 1D144009
Display:
Used by:
Cause: A lead could not be found.
Remedy: Check the lead width, the part shape, and the conditions under which the image is taken.
------------------------------
Code: 1D14400A
Display:
Used by:
Cause: A lead could not be found.
Remedy: Check the lead width, the part shape, and the conditions under which the image is taken.
------------------------------
Code: 1D14400B
Display:
Used by:
Cause: A lead could not be found.
Remedy: Check the lead width, the part shape, and the conditions under which the image is taken.
------------------------------
Code: 1D14400C
Display:
Used by:
Cause: A lead could not be found.
Remedy: Check the lead width, the part shape, and the conditions under which the image is taken.
------------------------------
Code: 1D14400D
Display:
Used by:
Cause: The body size is not in the acceptable range.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D14400E
第 1444 页
Display:
Used by:
Cause: A lead could not be found.
Remedy: Check the lead width, the part shape, and the conditions under which the image is taken.
------------------------------
Code: 1D14400F
Display:
Used by:
Cause: A lead could not be found.
Remedy: Check the lead width, the part shape, and the conditions under which the image is taken.
------------------------------
Code: 1D144010
Display:
Used by:
Cause: The lead width is not in the acceptable range.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D144011
Display:
Used by:
Cause: Unable to find the body.
Remedy: Check that the part is being picked properly, and check the part shape.
------------------------------
Code: 1D144012
Display:
Used by:
Cause: Unable to find the body.
Remedy: Check that the part is being picked properly, and check the part shape.
------------------------------
Code: 1D144013
Display:
Used by:
Cause: The body size is not in the acceptable range.
Remedy: Check the part shape, check that the part is being picked properly, and check the image taken
by vision processing.
------------------------------
Code: 1D148002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D148100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D148110