FUJI错误代码查询.pdf - 第2205页
------------------------------ Code: 51??1150 Display: The corresponding"SOLDER"data is not found. Used by: Cause: The data to be referenced by the sequence data specified in the item"ELEMENT"under&qu…
determined at the data reading of"BLOCK","SEQUENCE+"when"UNIT","PROGRAM"of the specified
production program was read.
Remedy: Check the data settings under"BLOCK","SOLDER"or"BLOCK","SOLCO"of"UNIT","PROGRAM". The
value for item"ELEMENT"under"BLOCK","SOLDER"cannot be the same as the value for
item"ELEMENT"under"BLOCK","SOLCO"line where item"GSQST"is set to'E'. If the values for
item"ELEMENT"are the same within the same block,no error occurs even if there is more than
one"ELEMENT"item. Since the name of block("SOLDER"or"SOLCO")and the "ELEMENT"value where the
error occurs is generally recorded in supplemental data,check the "ELEMENT"item of the block that was
not specified.
------------------------------
Code: 51??1127
Display: Too many GSS data "ELEMENT"entries.
Used by:
Cause: The GSS data"ELEMENT"entries specified under"BLOCK","SOLDER"and"BLOCK","SOLCO". This
was determined when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check the data settings under"BLOCK","SOLDER"or"BLOCK","SOLCO"of"UNIT","PROGRAM". The
number of individual"ELEMENT"values which can be set under"BLOCK","SOLDER"or"BLOCK","SOLCO"are
limited.Since the name of the block("SOLDER"or"SOLCO")and the "ELEMENT"value where the error occurs
is generally recorded in supplemental data,check there.
------------------------------
Code: 51??1140
Display: No"BLOCK","SOLDER"under"UNIT","PROGRAM"
Used by:
Cause: "BLOCK","SOLDER"was not found under"UNIT","PROGRAM"of the specified production program.
Remedy: Check the settings made for"BLOCK","SOLDER"under"UNIT","PROGRAM"of the production
program.
------------------------------
Code: 51??1141
Display: Multiple"BLOCK","SOLDER"sections.
Used by:
Cause: Multiple"BLOCK","SOLDER"sections are defined under"UNIT","PROGRAM"of the specified
production program. This is reported only at the default check.
Remedy: Check the settings made for"BLOCK","SOLDER"under"UNIT","PROGRAM"of the production
program.
------------------------------
Code: 51??1142
Display: "ELEMENT"is not found under"BLOCK","SOLDER"
Used by:
Cause: The item"ELEMENT"under"BLOCK","SOLDER"does not exist. This was determined
when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check the settings under"BLOCK","SOLDER"of"UNIT","PROGRAM"in the production program.
------------------------------
Code: 51??1143
Display: Multiple"ELEMENT"under"BLOCK","SOLDER".
Used by:
Cause: The values within the specified item"ELEMENT"under"BLOCK","SOLDER"are the same. This was
determined when"UNIT","PROGRAM"of the specified production program was read. This is reported only at
the default check.
Remedy: Check the settings for item"ELEMENT"under"BLOCK","SOLDER"of"UNIT","PROGRAM"of the
production program. Since the name of the block("SOLDER")of the specified"ELEMENT"item and the value
of the item"ELEMENT"where the error occurs is generally recorded in supplemental data,check there.
第 2204 页
------------------------------
Code: 51??1150
Display: The corresponding"SOLDER"data is not found.
Used by:
Cause: The data to be referenced by the sequence data specified in the
item"ELEMENT"under"BLOCK","SOLDER"does not exist. This was determined when"UNIT","PROGRAM"of
the specified production program was read.
Remedy: Check the settings for the item"ELEMENT"under"BLOCK","SOLDER"of"UNIT","PROGRAM"in the
production program. Since the name of the block("SOLDER")and the value of the item"ELEMENT"which is
referenced by the sequence data is generally recorded in supplemental data,check there.
Additionally,check the relating references of the"SOLDER"data
under"BLOCK","SEQUENCE+"of"UNIT","PROGRAM".
------------------------------
Code: 51??1151
Display: No item definition lines in item"ELEMENT"under"BLOCK","SOLDER".
Used by:
Cause: There are no item definition lines in the specified item "ELEMENT"under"BLOCK","SOLDER". This
was determined when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check the settings for the item"ELEMENT"under"BLOCK","SOLDER"of"UNIT","PROGRAM"in the
production program. Since the name of the block("SOLDER")and the value of the item"ELEMENT"are
generally reported in supplemental data,check there.
------------------------------
Code: 51??1152
Display: "ELEMENT"item definition format error under"BLOCK","SOLDER".
Used by:
Cause: A format error was discovered in the"ELEMENT"item definition lines
under"BLOCK","SOLDER"when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check the"ELEMENT"item definition line settings
under"BLOCK","SOLDER"of"UNIT","PROGRAM"in the production program. Since the name of the
block("SOLDER")and the value of the item"ELEMENT"are generally reported in supplemental data,check
there.
------------------------------
Code: 51??1153
Display: No data in"ELEMENT"under"BLOCK","SOLDER".
Used by:
Cause: No data exists for item"ELEMENT"under"BLOCK","SOLDER". This was determined
when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check item"ELEMENT"under"BLOCK","SOLDER"of"UNIT","PROGRAM"in the production
program. At least one line of data must be input for the item"ELEMENT"under"BLOCK","SOLDER". Since
the name of the block("SOLDER")and the value of the item"ELEMENT"are generally reported in
supplemental data,check there.
------------------------------
Code: 51??1154
Display: "ELEMENT"format error under"BLOCK","SOLDER".
Used by:
Cause: A format error was discovered at the reading of"ELEMENT"data
under"BLOCK","SOLDER"when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check the"ELEMENT"data settings under"BLOCK","SOLDER"of"UNIT","PROGRAM"in the
production program. Since the name of the block("SOLDER")and the value of the item"ELEMENT"are
generally reported in supplemental data,check there.
------------------------------
第 2205 页
Code: 51??1155
Display: "GCCGSSN"not defined.
Used by:
Cause: There is no"GCCGSSN"definition in the"ELEMENT"item delcaration line
under"BLOCK","SOLDER". This was determined when"UNIT","PROGRAM"of the specified production
program was read.
Remedy: Check the settings for item"ELEMENT"under"BLOCK","SOLDER"of"UNIT","PROGRAM".
The"GCCGSSN"item setting is required. Since the name of the block("SOLDER")and the value of the
item"ELEMENT"are generally reported in supplemental data,check there.
------------------------------
Code: 51??1156
Display: Missing number in"GCCGSSN".
Used by:
Cause: There is a missing number in the"GCCGSSN"item of the"ELEMENT"item
under"BLOCK","SOLDER". This was determined when"UNIT","PROGRAM"of the specified production
program was read.
Remedy: Check the"ELEMENT"item under"BLOCK","SOLDER"of"UNIT","PROGRAM". The"GCCGSSN"item
must have values set from 1 to the final number in sequential order. Since the name of the
block("SOLDER")and the value of the item"ELEMENT"are generally reported in supplemental data,check
there. Missing numbers are also reported at the default check.
------------------------------
Code: 51??1160
Display: No"BLOCK","SOLCO"under"UNIT","PROGRAM".
Used by:
Cause: "BLOCK","SOLCO"was not found under"UNIT","PROGRAM"of the specified production program.
Remedy: Check the settings made for"BLOCK","SOLCO"under"UNIT","PROGRAM"of the production
program.
------------------------------
Code: 51??1161
Display: Multiple"BLOCK","SOLCO"sections.
Used by:
Cause: Multiple"BLOCK","SOLCO"sections are defined under"UNIT","PROGRAM"of the specified
production program. This is reported only at the default check.
Remedy: Check the settings made for"BLOCK","SOLCO"under"UNIT","PROGRAM"of the production
program.
------------------------------
Code: 51??1162
Display: There is no"ELEMENT"in"BLOCK","SOLCO".
Used by:
Cause: The item"ELEMENT"under"BLOCK","SOLCO"does not exist. This was determined
when"UNIT","PROGRAM"of the specified production program was read.
Remedy: Check the settings under"BLOCK","SOLCO"under"UNIT","PROGRAM"of the production program.
------------------------------
Code: 51??1163
Display: Multiple"ELEMENT"under"BLOCK","SOLCO".
Used by:
Cause: The values within the specified item"ELEMENT"under"BLOCK","SOLCO"are the same. This was
determined when"UNIT","PROGRAM"of the specified production program was read. This is reported only at
the default check.
Remedy: Check the settings for item"ELEMENT"under"BLOCK","SOLCO"of"UNIT","PROGRAM"of the
production program. Since the name of the block("SOLCO")of the specified"ELEMENT"item and the value
第 2206 页